The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Reduction of physiological fluctuations in fMRI using digital filters
Abstract
Data obtained from functional magnetic resonance imaging are often limtted by a low signal‐to‐noise ratio. The time‐course data obtained from activated regions contain both system noise and physiological noise, primarily linked to the heart and respiratory rates, that are superimposed on task induced signals. Time averaging of a practical number of data sets is not very effective in improving the signal‐to‐noise ratio because netther system nor physiological noise is truly random. In this paper, a method is presented for fittering un‐wanted physiological fluctuations, including aliased signals that are formed as a result of long repetition time (TR) values. A pulse oximeter was used to obtain cardiac and respiratory Information during the scanning period. Fintte impulse response band‐reject digital fitters were designed to remove the physiological fluctuations. For comparison, cross‐correlation analyses were performed at the same tevel of statistical significance on both fittered and unfiltered data. We demonstrate that this method can improve the detection of weak signals without increasing the probability of false positives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Detection, Estimation, and Modulation Theory, Part I
Van Trees, H. L. (2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471221082 · Cited by 3,891
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Nonparametrics: Statistical Methods Based on Ranks.
Beaver, R. J., & Lehmann, E. L. (1976) · Biometrics · doi:10.2307/2529529 · Cited by 2,047
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Self-citationFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Self-citationToutenburg, H. (1977) · ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik · doi:10.1002/zamm.19770570922 · Cited by 787
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Functional magnetic resonance imaging (FMRI) of the human brain
DeYoe, E. A., Bandettini, P., Neitz, J., Miller, D., & Winans, P. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90191-0 · Cited by 395
Self-citation
Cited by
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502
Functional connectivity in single and multislice echoplanar imaging using resting-state fluctuations
Lowe, M. J., Mock, B. J., & Sorenson, J. A. (1998) · NeuroImage · doi:10.1006/nimg.1997.0315 · Cited by 1,394
Birn, R. M., Diamond, J. B., Smith, M. A., & Bandettini, P. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.048 · Cited by 1,358
Competition between functional brain networks mediates behavioral variability
Kelly, A. M. C., Uddin, L. Q., Biswal, B. B., Castellanos, F. X., & Milham, M. P. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.008 · Cited by 1,287
Self-citationUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Metadata
- Authors
- Biswal, B., Deyoe, E. A., & Hyde, J. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-01
- Volume
- 35
- Issue
- 1
- Pages
- 107-113
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2066313169
- Cited by
- 302
- References
- 13
- FWCI
- 15.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduction of physiological fluctuations in fMRI using digital filters. https://app.cochat.ai/papers/10.1002/mrm.1910350114
- The paper
- Biswal, B., Deyoe, E. A., & Hyde, J. S. (1996). Reduction of physiological fluctuations in fMRI using digital filters. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910350114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.