Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 302

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Reduction of physiological fluctuations in fMRI using digital filters

Biswal, Bharat, Deyoe, Edgar A., Hyde, James S. · 1996 · Magnetic Resonance in Medicine

Abstract

Data obtained from functional magnetic resonance imaging are often limtted by a low signal‐to‐noise ratio. The time‐course data obtained from activated regions contain both system noise and physiological noise, primarily linked to the heart and respiratory rates, that are superimposed on task induced signals. Time averaging of a practical number of data sets is not very effective in improving the signal‐to‐noise ratio because netther system nor physiological noise is truly random. In this paper, a method is presented for fittering un‐wanted physiological fluctuations, including aliased signals that are formed as a result of long repetition time (TR) values. A pulse oximeter was used to obtain cardiac and respiratory Information during the scanning period. Fintte impulse response band‐reject digital fitters were designed to remove the physiological fluctuations. For comparison, cross‐correlation analyses were performed at the same tevel of statistical significance on both fittered and unfiltered data. We demonstrate that this method can improve the detection of weak signals without increasing the probability of false positives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910350114

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 302

Metadata

Authors
Biswal, B., Deyoe, E. A., & Hyde, J. S.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1996-01
Volume
35
Issue
1
Pages
107-113
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2066313169
Cited by
302
References
13
FWCI
15.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.