The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Noise in MRI
Abstract
This study analyzes the signal‐to‐noise ratio (SNR) in magnetic resonance imaging. The factors that determine the SNR are derived starting from basic principles. The SNR, for a given object, is shown to be proportional to the voxel volume and the square root of the acquisition time. The noise generated by the body is derived using a cylindrical model and is shown to be proportional to the square of the radius and the square root of the length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Statistical Properties of a Sine Wave Plus Random Noise
Rice, S. O. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb01334.x · Cited by 909
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Radiofrequency losses in NMR experiments on electrically conducting samples
Gadian, D. G., & Robinson, F. N. H. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90023-4 · Cited by 172
Volumetric NMR imaging with time‐varying gradients
Macovski, A. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020105 · Cited by 125
Self-citation
Cited by
Etkin, A., Klemenhagen, K. C., Dudman, J. T., Rogan, M. T., Hen, R., Kandel, E. R., & Hirsch, J. (2004) · Neuron · doi:10.1016/j.neuron.2004.12.006 · Cited by 679
Wavelet-based Rician noise removal for magnetic resonance imaging
Nowak, R. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.791966 · Cited by 620
A versatile wavelet domain noise filtration technique for medical imaging
Pizurica, A., Philips, W., Lemahieu, I., & Acheroy, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809588 · Cited by 531
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Compressed sensing MRI: a review of the clinical literature
Jaspan, O. N., Fleysher, R., & Lipton, M. L. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150487 · Cited by 393
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
A survey on the magnetic resonance image denoising methods
Mohan, J., Krishnaveni, V., & Guo, Y. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.007 · Cited by 295
Noise reduction for magnetic resonance images via adaptive multiscale products thresholding
Bao, P., & Zhang, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816958 · Cited by 295
A simulation study on the resolution and sensitivity of magnetic particle imaging
Weizenecker, J., Borgert, J., & Gleich, B. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/001 · Cited by 267
The future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Plug-and-Play Methods for Magnetic Resonance Imaging: Using Denoisers for Image Recovery
Ahmad, R., Bouman, C. A., Buzzard, G. T., Chan, S., Liu, S., Reehorst, E. T., & Schniter, P. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2949470 · Cited by 261
Constrained Gaussian mixture model framework for automatic segmentation of MR brain images
Greenspan, H., Ruf, A., & Goldberger, J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880668 · Cited by 254
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Denoising of Dynamic Contrast-Enhanced MR Images Using Dynamic Nonlocal Means
Gal, Y., Mehnert, A. J. H., Bradley, A. P., McMahon, K., Kennedy, D., & Crozier, S. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2026575 · Cited by 78
Top-Level Design and Simulated Performance of the First Portable CT-MR Scanner
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X. (2022) · IEEE Access · doi:10.1109/access.2022.3208278 · Cited by 4
“Hence, we add to S(kx, ky) white noise with standard deviation σ = C0 √ B0/ √ TACQ [18], where C0 is a calibration constant obtained empirically on an MRI scanner available in our lab, and TACQ is the total acquisition time.”
Method
Metadata
- Authors
- Macovski, A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-09
- Volume
- 36
- Issue
- 3
- Pages
- 494-497
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2011344206
- Cited by
- 420
- References
- 5
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.