Improved image registration by using fourier interpolation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a technique for performing two‐dimensional rigid‐body image registration for functional magnetic resonance images (fMRI). The method provides accurate motion correction without local distortion. The approach is to perform the translation and rotation in the Fourier domain. For images sampled on a grid, such as in echo‐planar imaging (EPI), one potential stumbling block to this approach is the computational burden of reconstruction, since the rotated image will no longer be on the Cartesian grid. A method of approximating rotations via local translations (shearing) is presented, which keeps the data on the Cartesian grid. This can provide quite accurate approximations with only a moderate amount of computation. A mean squared error (MSE) criterion is used for determining the registration parameters. This method is tested on several sets of simulated images and shown to have an accuracy ranging from 0.02 to 0.3 pixels for images with SNRs ranging from 100 to 10, respectively. They techniques have been tested on several sets of images. They are shown to work well on real subjects, for both echo‐planar and spiral data acquisition schemes. The techniques are used in an activation study in which the subject moved his head during image collection. After use of this registration technique, the activation is easily detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212 · cited 1×
“The process of image registration can be divided into two separate steps: (1) Determining the registration parameters; (2) Performing the image registration.”
BackgroundOgawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Forman, S. D., Cohen, J. D., Fitzgerald, M., Eddy, W. F., Mintun, M. A., & Noll, D. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330508 · Cited by 3,202
Self-citationTime course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Cited by
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Modeling Geometric Deformations in EPI Time Series
Andersson, J. L. R., Hutton, C., Ashburner, J., Turner, R., & Friston, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0746 · Cited by 1,011
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
Pipe, J. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l · Cited by 928
Real-time 3D image registration for functional MRI
Cox, R. W., & Jesmanowicz, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199912)42:6<1014::aid-mrm4>3.0.co;2-f · Cited by 663
A chronology of interpolation: from ancient astronomy to modern signal and image processing
Meijering, E. (2002) · Proceedings of the IEEE · doi:10.1109/5.993400 · Cited by 662
Metadata
- Authors
- Eddyy, W. F., Fitzgerald, M., & Noll, D. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1996-12
- Volume
- 36
- Issue
- 6
- Pages
- 923-931
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2083375686
- Cited by
- 142
- References
- 5
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved image registration by using fourier interpolation. https://app.cochat.ai/papers/10.1002/mrm.1910360615
- The paper
- Eddyy, W. F., Fitzgerald, M., & Noll, D. C. (1996). Improved image registration by using fourier interpolation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910360615
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.