The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Perfusion imaging by a flow‐sensitive alternating inversion recovery (Fair) technique: Application to functional brain imaging
Abstract
Perfusion is a crucial physiological parameter for tissue function. To obtain perfusion‐weighted images and consequently to measure cerebral blood flow (CBF), a newly developed flow‐sensitive alternating inversion recovery (FAIR) technique was used. Dependency of FAIR signal on inversion times (TI) was examined; signal is predominantly located in large vessels at short TI, whereas it is diffused into gray matter areas at longer TI. CBF of gray matter areas in the human brain is 71 ± 15 SD ml/100 g/min (n = 6). In fMRI studies, micro‐ and macrovessel inflow contributions can be obtained by adjusting TIs. Signal changes in large vessel areas including the scalp were seen during finger opposition at a TI of 0.4 s; however, these were not observed at a longer TI of 1.4 s. To compare with commonly used BOLD and slice selective inversion recovery techniques, FAIR and BOLD images were acquired at the same time during unilateral finger opposition. Generally, activation sites determined by three techniques are consistent. However, activation of some areas can be detected only by FAIR, not by BOLD, suggesting that the oxygen consumption increase couples with the CBF change completely. Relative and absolute CBF changes in the contralateral motor cortex are 53 ± 17% SD (n = 9) and 27 ± 11 SD ml/100 g/min (n = 9), respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Forman, S. D., Cohen, J. D., Fitzgerald, M., Eddy, W. F., Mintun, M. A., & Noll, D. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330508 · Cited by 3,202
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Regional cerebral blood flow and oxygen consumption in human aging
Pantano, P., Baron, J. C., Lebrun-Grandié, P., Duquesnoy, N., Bousser, M. G., & Comar, D. (1984) · Stroke · doi:10.1161/01.str.15.4.635 · Cited by 341
Seitz, R. J., & Roland, P. E. (1992) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1992.tb00862.x · Cited by 321
Cited by
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Metadata
- Authors
- Kim, S., & Tsekos, N. V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 37
- Issue
- 3
- Pages
- 425-435
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2056388234
- Cited by
- 247
- References
- 6
- FWCI
- 22.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.