The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Perfusion imaging by a flow‐sensitive alternating inversion recovery (Fair) technique: Application to functional brain imaging
Abstract
Perfusion is a crucial physiological parameter for tissue function. To obtain perfusion‐weighted images and consequently to measure cerebral blood flow (CBF), a newly developed flow‐sensitive alternating inversion recovery (FAIR) technique was used. Dependency of FAIR signal on inversion times (TI) was examined; signal is predominantly located in large vessels at short TI, whereas it is diffused into gray matter areas at longer TI. CBF of gray matter areas in the human brain is 71 ± 15 SD ml/100 g/min (n = 6). In fMRI studies, micro‐ and macrovessel inflow contributions can be obtained by adjusting TIs. Signal changes in large vessel areas including the scalp were seen during finger opposition at a TI of 0.4 s; however, these were not observed at a longer TI of 1.4 s. To compare with commonly used BOLD and slice selective inversion recovery techniques, FAIR and BOLD images were acquired at the same time during unilateral finger opposition. Generally, activation sites determined by three techniques are consistent. However, activation of some areas can be detected only by FAIR, not by BOLD, suggesting that the oxygen consumption increase couples with the CBF change completely. Relative and absolute CBF changes in the contralateral motor cortex are 53 ± 17% SD (n = 9) and 27 ± 11 SD ml/100 g/min (n = 9), respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Forman, S. D., Cohen, J. D., Fitzgerald, M., Eddy, W. F., Mintun, M. A., & Noll, D. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330508 · Cited by 3,202
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationLai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Regional cerebral blood flow and oxygen consumption in human aging
Pantano, P., Baron, J. C., Lebrun-Grandié, P., Duquesnoy, N., Bousser, M. G., & Comar, D. (1984) · Stroke · doi:10.1161/01.str.15.4.635 · Cited by 341
Seitz, R. J., & Roland, P. E. (1992) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1992.tb00862.x · Cited by 321
Cited by
A general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Luh, W.-M., Wong, E. C., Bandettini, P. A., & Hyde, J. S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1246::aid-mrm22>3.0.co;2-n · Cited by 506
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
ON THE CHARACTERISTICS OF FUNCTIONAL MAGNETIC RESONANCE IMAGING OF THE BRAIN
Ogawa, S., Menon, R. S., Kim, S.-G., & Ugurbil, K. (1998) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.27.1.447 · Cited by 343
Self-citationLocalized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Self-citationUsing network science to evaluate exercise-associated brain changes in older adults.
Burdette (2010) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2010.00023 · Cited by 320
Model‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Arterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Kim, S.-G., Rostrup, E., Larsson, H. B. W., Ogawa, S., & Paulson, O. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1152::aid-mrm11>3.0.co;2-t · Cited by 268
Self-citationPerfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Acute effect of a high nitrate diet on brain perfusion in older adults
Presley, T. D., Morgan, A. R., Bechtold, E., Clodfelter, W., Dove, R. W., Jennings, J. M., Kraft, R. A., Bruce King, S., Laurienti, P. J., Jack Rejeski, W., et al. (2011) · Nitric Oxide · doi:10.1016/j.niox.2010.10.002 · Cited by 238
The effect of daily caffeine use on cerebral blood flow: How much caffeine can we tolerate?
Addicott, M. A., Yang, L. L., Peiffer, A. M., Burnett, L. R., Burdette, J. H., Chen, M. Y., Hayasaka, S., Kraft, R. A., Maldjian, J. A., & Laurienti, P. J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20732 · Cited by 210
Brain neurochemical and hemodynamic findings in the NY1DD mouse model of mild sickle cell disease
Cui, M., Suzuka, S. M., Branch, N. A., Ambadipudi, K., Thangaswamy, S., Acharya, S. A., Billett, H. H., & Branch, C. A. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3692 · Cited by 11
Metadata
- Authors
- Kim, S., & Tsekos, N. V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 37
- Issue
- 3
- Pages
- 425-435
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2056388234
- Cited by
- 247
- References
- 7
- FWCI
- 22.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.