The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A simplified method to measure the diffusion tensor from seven MR images
Abstract
Analytical expressions of the diffusion tensor of water, D, and of scalar invariants derived from it, are given in terms of the intensities of seven diffusion‐weighted images (DWIs). These formulas simplify the post‐processing steps required in diffusion tensor imaging, including estimating D in each voxel (from the set of b‐matrices and their corresponding DWIs), and then computing its eigenvalues, eigenvectors, and scalar invariants. In a study conducted using artifact‐free DWIs with high diffusion weighting (b max ˜ 900 s/mm 2), maps of Trace(D) and the Relative and Lattice Anisotropy indices calculated analytically and by multivariate linear regression showed excellent agreement in brain parenchyma of a healthy living cat. However, the quality of the analytically computed maps degraded markedly as diffusion weighting was reduced. Although diffusion tensor MRI with seven DWIs may be useful for clinical applications where rapid scanning and data processing are required, it does not provide estimates of the uncertainty of the measured imaging parameters, rendering it susceptible to noise and systematic artifacts. Therefore, care should be taken when using this technique in radiological applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
Self-citationBasser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Self-citationEstimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Self-citationDiffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citationToward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Self-citationIntroduction to applied mathematics.
(1986) · Mathematics and Computers in Simulation · doi:10.1016/0378-4754(86)90036-4 · Cited by 1,495
Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R. (1995) · Annals of Neurology · doi:10.1002/ana.410370214 · Cited by 1,004
Introduction to Applied Mathematics
Strang, G., & Freund, L. B. (1986) · Journal of Applied Mechanics · doi:10.1115/1.3171799 · Cited by 664
Principles and Application of Self-Diffusion Measurements by Nuclear Magnetic Resonance
KÄRGER, J., PFEIFER, H., & HEINK, W. (1988) · Advances in Magnetic and Optical Resonance · doi:10.1016/b978-0-12-025512-2.50004-x · Cited by 660
Molecular diffusion nuclear magnetic resonance imaging.
Bihan, D. L. (1991) · PubMed · Cited by 438
Diffusion and Perfusion Magnetic Resonance Imaging: Applications to Functional MRI
Bihan, D. L., & Warach, S. J. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199509000-00032 · Cited by 397
Conturo, T. E., McKinstry, R. C., Akbudak, E., & Robinson, B. H. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350319 · Cited by 300
Imaging myocardial fiber architecture in vivo with magnetic resonance
Reese, T. G., Weisskoff, R. M., Smith, R. N., Rosen, B. R., Dinsmore, R. E., & Wedeen, V. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340603 · Cited by 292
Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan
Mori, S., & Van Zijl, P. C. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330107 · Cited by 278
The b matrix in diffusion tensor echo‐planar imaging
Mattiello, J., Basser, P. J., & Le Bihan, D. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370226 · Cited by 239
Self-citationAnalytical Expressions for the b Matrix in NMR Diffusion Imaging and Spectroscopy
Mattiello, J., Basser, P. J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1103 · Cited by 222
Self-citationAbsolute Quantitation of Diffusion Constants in Human Stroke
Uluğ, A. M., Beauchamp, N., Bryan, R. N., & van Zijl, P. C. M. (1997) · Stroke · doi:10.1161/01.str.28.3.483 · Cited by 180
Optimized isotropic diffusion weighting
Wong, E. C., Cox, R. W., & Song, A. W. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340202 · Cited by 168
MR Diffusion Imaging of the Human Brain
Chien, D., Buxton, R. B., Kwong, K. K., Brady, T. J., & Rosen, B. R. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199007000-00003 · Cited by 154
Anisotropy of water diffusion in the myocardium of the rat.
Garrido, L., Wedeen, V. J., Kwong, K. K., Spencer, U. M., & Kantor, H. L. (1994) · Circulation Research · doi:10.1161/01.res.74.5.789 · Cited by 137
Neeman, M., Freyer, J. P., & Sillerud, L. O. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90136-w · Cited by 115
Hsu, E. W., & Mori, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340210 · Cited by 114
A method for myelin fiber orientation mapping using diffusion-weighted MR images
Coremans, J., Luypaert, R., Verhelle, F., Stadnik, T. W., & Osteaux, M. M. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92538-0 · Cited by 87
Single‐shot diffusion MRI of human brain on a conventional clinical instrument
Liu, G., van Gelderen, P., Duyn, J. H., & MOONEN, C. T. W. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350508 · Cited by 45
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Dysmyelination revealed through MRI as increased radial (but unchanged axial) diffusion of water
Song, S.-K., Sun, S.-W., Ramsbottom, M. J., Chang, C., Russell, J., & Cross, A. H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1267 · Cited by 2,582
Song, S.-K., Sun, S.-W., Ju, W.-K., Lin, S.-J., Cross, A. H., & Neufeld, A. H. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.005 · Cited by 1,738
Demyelination increases radial diffusivity in corpus callosum of mouse brain
Song, S.-K., Yoshino, J., Le, T. Q., Lin, S.-J., Sun, S.-W., Cross, A. H., & Armstrong, R. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.028 · Cited by 1,658
Metadata
- Authors
- Basser, P. J., & Pierpaoli, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 39
- Issue
- 6
- Pages
- 928-934
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2032011764
- Cited by
- 583
- References
- 25
- FWCI
- 18.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.