The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Targeted nanoparticles for quantitative imaging of sparse molecular epitopes with MRI
Open accessAbstract
Before molecular imaging with MRI can be applied clinically, certain problems, such as the potential sparseness of molecular epitopes on targeted cell surfaces, and the relative weakness of conventional targeted MR contrast agents, must be overcome. Accordingly, the conditions for diagnostic conspicuity that apply to any paramagnetic MRI contrast agent with known intrinsic relaxivity were examined in this study. A highly potent paramagnetic liquid perfluorocarbon nanoparticle contrast agent (∼250 nm diameter, >90000 Gd 3+/particle) was imaged at 1.5 T and used to successfully predict a range of sparse concentrations in experimental phantoms with the use of standard MR signal models. Additionally, we cultured and targeted the smooth muscle cell (SMC) monolayers that express “tissue factor,” a glycoprotein of crucial significance to hemostasis and response to vascular injury, by conjugating an anti‐tissue factor antibody fragment to the nanoparticles to effect specific binding. Quantification of the signal from cell monolayers imaged at 1.5 T demonstrated, as predicted via modeling, that only picomolar concentrations of paramagnetic perfluorocarbon nanoparticles were required for the detection and quantification of tissue factor at clinical field strengths. Thus, for targeted paramagnetic agents carrying high payloads of gadolinium, it is possible to quantify molecular epitopes present in picomolar concentrations in single cells with routine MRI. Magn Reson Med 51:480–486, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
The Sensitivity Performance of the Human Eye on an Absolute Scale*
Rose, A. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000196 · Cited by 931
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Self-citationFlacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Self-citationWinter, P. M., Caruthers, S. D., Kassner, A., Harris, T. D., Chinen, L. K., Allen, J. S., Lacy, E. K., Zhang, H., Robertson, J. D., Wickline, S. A., et al. (2003) · PubMed · Cited by 371
Self-citationMolecular Imaging: Exploring the Next Frontier
Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se18609 · Cited by 339
Lanza, G. M., Yu, X., Winter, P. M., Abendschein, D. R., Karukstis, K. K., Scott, M. J., Chinen, L. K., Fuhrhop, R. W., Scherrer, D. E., & Wickline, S. A. (2002) · Circulation · doi:10.1161/01.cir.0000044020.27990.32 · Cited by 287
Self-citationYu, X., Song, S.-K., Chen, J., Scott, M. J., Fuhrhop, R. J., Hall, C. S., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<867::aid-mrm7>3.0.co;2-p · Cited by 238
Self-citationNanotechnology for Molecular Imaging and Targeted Therapy
Wickline, S. A., & Lanza, G. M. (2003) · Circulation · doi:10.1161/01.cir.0000059651.17045.77 · Cited by 226
Self-citationImproved molecular imaging contrast agent for detection of human thrombus
Winter, P. M., Caruthers, S. D., Yu, X., Song, S., Chen, J., Miller, B., Bulte, J. W. M., Robertson, J. D., Gaffney, P. J., Wickline, S. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10532 · Cited by 189
Self-citationBasic physics of MR contrast agents and maximization of image contrast
Hendrick, R. E., & Haacke, E. M. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030126 · Cited by 151
In vivo imaging of gene and cell therapies
Allport, J. R., & Weissleder, R. (2001) · Experimental Hematology · doi:10.1016/s0301-472x(01)00739-1 · Cited by 114
Lanza, G. M., Abendschein, D. R., Hall, C. S., Scott, M. J., Scherrer, D. E., Houseman, A., Miller, J. G., & Wickline, S. A. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105840 · Cited by 104
Self-citationLanza, G. M., Abendschein, D. R., Hall, C. S., Marsh, J. N., Scott, M. J., Scherrer, D. E., & Wickline, S. A. (2000) · Investigative Radiology · doi:10.1097/00004424-200004000-00003 · Cited by 88
Self-citationMolecular imaging, targeted therapeutics, and nanoscience
Wickline, S. A., & Lanza, G. M. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10422 · Cited by 79
Self-citationOptimizing tissue contrast in magnetic resonance imaging
Hendrick, R. E., Nelson, T. R., & Hendee, W. R. (1984) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(84)90005-5 · Cited by 77
Gillies, R. J. (2002) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10450 · Cited by 65
TARGETED CONTRAST AGENTS IN MR IMAGING
Gupta, H., & Weissleder, R. (1996) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00560-2 · Cited by 61
Basic principles of magnetic resonance contrast agents.
Kirsch, J. E. (1991) · PubMed · Cited by 49
Pierre, J. S., Yang, L., Tamirisa, K., Scherrer, D. E., Ciechi, P. D., Eisenberg, P. R., Tolunay, E., & Abendschein, D. R. (1999) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.19.9.2263 · Cited by 43
Self-citationBasic principles of magnetic resonance contrast agents
Kirsch, J. E. (1991) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-199103000-00003 · Cited by 41
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Metadata
- Authors
- Morawski, A. M., Winter, P. M., Crowder, K. C., Caruthers, S. D., Fuhrhop, R. W., Scott, M. J., Robertson, J. D., Abendschein, D. R., Lanza, G. M., & Wickline, S. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-02-25
- Volume
- 51
- Issue
- 3
- Pages
- 480-486
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1967727706
- Cited by
- 271
- References
- 22
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.