The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls
Abstract
The aim of this study was to test a prototype MRI‐compatible focused ultrasound phased array system for trans‐skull brain tissue ablation. Rabbit thigh muscle and brain were sonicated with a prototype, hemispherical 500‐element ultrasound phased array operating at frequencies of 700–800 kHz. An ex vivo human skull sample was placed between the array and the animal tissue. The temperature elevation during 20–30‐sec sonications was monitored using MRI thermometry. The induced focal lesions were observed in T2 and contrast‐enhanced T1‐weighted fast spin echo images. Whole brain histology evaluation was performed after the sonications. The results showed that sharp temperature elevations can be produced both in the thigh muscle and in the brain. High‐power sonications (600–1080 W) produced peak temperatures up to 55°C and focal lesions that were consistent with thermal tissue damage. The lesion size was found to increase with increasing peak temperature. The device was then modified to operate in the orientation that will be used in the clinic and successfully tested in phantom experiments. As a conclusion, this study demonstrates that it is possible to create ultrasound‐induced lesions in vivo through a human skull under MRI guidance with this large‐scale phased array. Magn Reson Med 52:100–107, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationComprehensive compilation of empirical ultrasonic properties of mammalian tissues
Goss, S. A., Johnston, R. L., & Dunn, F. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.382016 · Cited by 1,115
A precise and fast temperature mapping using water proton chemical shift
Ishihara, Y., Calderon, A., Watanabe, H., Okamoto, K., Suzuki, Y., Kuroda, K., & Suzuki, Y. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340606 · Cited by 1,027
MR Imaging-guided Focused Ultrasound Surgery of Fibroadenomas in the Breast: A Feasibility Study
Hynynen, K., Pomeroy, O., Smith, D. N., Huber, P. E., McDannold, N. J., Kettenbach, J., Baum, J., Singer, S., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap02176 · Cited by 634
Self-citationA non-invasive method for focusing ultrasound through the human skull
Clement, G. T., & Hynynen, K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/301 · Cited by 510
Self-citationDemonstration of Potential Noninvasive Ultrasound Brain Therapy Through an Intact Skull
Hynynen, K., & Jolesz, F. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00269-x · Cited by 446
Self-citationMRI‐guided noninvasive ultrasound surgery
Hynynen, K., Darkazanli, A., Unger, E., & Schenck, J. F. (1993) · Medical Physics · doi:10.1118/1.597093 · Cited by 327
Self-citationUltrasonic Lesions in the Mammalian Central Nervous System
Fry, W. J., Fry, F. J., Barnard, J. W., Krumins, R. F., & Brennan, J. F. (1955) · Science · doi:10.1126/science.122.3168.517 · Cited by 321
Thomas, J.-L., & Fink, M. A. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.542055 · Cited by 312
Vykhodtseva, N. I., Hynynen, K., & Damianou, C. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)00038-s · Cited by 230
Self-citationThermal effects of focused ultrasound on the brain: determination with MR imaging.
Hynynen, K., Vykhodtseva, N. I., Chung, A. H., Sorrentino, V, Colucci, V, & Jolesz, F. A. (1997) · Radiology · doi:10.1148/radiology.204.1.9205255 · Cited by 229
Self-citationFocusing of therapeutic ultrasound through a human skull: A numerical study
Sun, J., & Hynynen, K. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.424383 · Cited by 213
Self-citationA hemisphere array for non-invasive ultrasound brain therapy and surgery
Clement, G. T., Sun, J., Giesecke, T., & Hynynen, K. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/314 · Cited by 186
Self-citationTreatment of localised prostate cancer with transrectal high intensity focused ultrasound
Chapelon, J. Y., Ribault, M., Birer, A., Vernier, F., Souchon, R., & Gelet, A. (1999) · European Journal of Ultrasound · doi:10.1016/s0929-8266(99)00005-1 · Cited by 166
Histology of Cerebral Lesions Produced by Focused Ultrasound.
Lynn, J. G., & PUTNAM, T. J. (1944) · PubMed · Cited by 157
A simple method for production of trackless focal lesions with focused ultrasound: physical factors
Lele, P. P. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006862 · Cited by 149
Sun, J., & Hynynen, K. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426863 · Cited by 139
Self-citationMRI detection of the thermal effects of focused ultrasound on the brain
Vykhodtseva, N. I., Sorrentino, V., Jolesz, F. A., Bronson, R. T., & Hynynen, K. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00216-7 · Cited by 134
Self-citationUmemura, S.-I., Kawabata, K.-I., & Sasaki, K. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.418120 · Cited by 107
Cited by
Transcranial Pulsed Ultrasound Stimulates Intact Brain Circuits
Tufail, Y., Matyushov, A., Baldwin, N., Tauchmann, M. L., Georges, J., Yoshihiro, A., Tillery, S. I. H., & Tyler, W. J. (2010) · Neuron · doi:10.1016/j.neuron.2010.05.008 · Cited by 977
A Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Huss, D., Voss, T., Loomba, J., Khaled, M., Zadicario, E., Frysinger, R. C., Sperling, S. A., Wylie, S., Monteith, S. J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300962 · Cited by 875
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
A Review of Tissue Substitutes for Ultrasound Imaging
Culjat, M. O., Goldenberg, D., Tewari, P., & Singh, R. S. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.012 · Cited by 659
Kinoshita, M., McDannold, N., Jolesz, F. A., & Hynynen, K. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604318103 · Cited by 645
Self-citation
Metadata
- Authors
- Hynynen, K., Clement, G. T., McDannold, N., Vykhodtseva, N., King, R., White, P. J., Vitek, S., & Jolesz, F. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-06-28
- Volume
- 52
- Issue
- 1
- Pages
- 100-107
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2144352085
- Cited by
- 340
- References
- 19
- FWCI
- 14.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.