Echo time optimization for linear combination myelin imaging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A 3‐echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal‐to‐noise ratio (SNR) of myelin–water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully optimizing the echo times a 50‐fold tissue water suppression is achieved along with a 10‐fold CSF suppression. For comparison 4, 5, and 32 echo filters are also designed using the same method. The SNR efficiency of these filters is very similar. The 3‐echo filter design was validated by phantom scans. In addition, multislice in vivo myelin images were acquired from both a healthy volunteer and a multiple sclerosis patient. Total scan time was 5 min. A uniform T2 filter is also designed to pass all white matter species with uniform gain. The myelin–water fraction of the in vivo 3‐echo data set is then measured by dividing the myelin image by the uniformly filtered image. Obtained myelin–water fractions compare well with previous work. Magn Reson Med 53:398–407, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High field MRI correlates of myelin content and axonal density in multiple sclerosis
Mottershead, J. P., Schmierer, K., Clemence, M., Thornton, J. S., Scaravilli, F., Barker, G. J., Tofts, P. S., Newcombe, J., Cuzner, M. L., Ordidge, R. J., et al. (2003) · Journal of Neurology · doi:10.1007/s00415-003-0192-3 · Cited by 296 · cited 1×
“[4], the SNR resulting from a given set of weights a [a1, .”
BackgroundThe contribution of magnetic resonance imaging to the diagnosis of multiple sclerosis
Fazekas, F., Barkhof, F., Filippi, M., Grossman, R. I., Li, D. K. B., McDonald, W. I., McFarland, H. F., Paty, D. W., Simon, J. H., Wolinsky, J. S., et al. (1999) · Neurology · doi:10.1212/wnl.53.3.448 · Cited by 287 · cited 1×
“a , [5]”
A pathology–MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain
Moore, G. R. W., Leung, E., MacKay, A. L., Vavasour, I. M., Whittall, K. P., Cover, K. S., Li, D. K. B., Hashimoto, S. A., Oger, J., Sprinkle, T. J., et al. (2000) · Neurology · doi:10.1212/wnl.55.10.1506 · Cited by 185
Cited by
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379
Magnetic Resonance Imaging of Myelin
Laule, C., Vavasour, I. M., Kolind, S. H., Li, D. K. B., Traboulsee, T. L., Moore, G. R. W., & MacKay, A. L. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.004 · Cited by 334
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Wozniak, J. R., & Lim, K. O. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.003 · Cited by 261
Self-citationWhole brain myelin mapping using T1- and T2-weighted MR imaging data.
Ganzetti, M., Wenderoth, N., & Mantini, D. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00671 · Cited by 225
“In recent years, other techniques have also been introduced, such as MCRI (MacKay et al., 1994; Whittall et al., 1997; Beaulieu et al., 1998; Gareau et al., 2000; Vidarsson et al., 2005; Laule et al., 2006; Oh et al., 2006; Madler et al., 2008) and mcDESPOT (Deoni et al., 2008, 2011).”
MethodResultPromise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
“…imaging (RSI) (White et al., 2013), white matter tract integrity (WMTI) from diffusion kurtosis imaging (DKI) (Fieremans et al., 2011), temporal diffusion spectroscopy (Xu et al., 2014), microscopic anisotropy obtainable from multiple pulsed field gradient MRI (Shemesh et al., 2012; Zhou et al.,…”
Method
Metadata
- Authors
- Vidarsson, L., Conolly, S. M., Lim, K. O., Gold, G. E., & Pauly, J. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-01-27
- Volume
- 53
- Issue
- 2
- Pages
- 398-407
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2161771791
- Cited by
- 44
- References
- 3
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.