CoChat

Echo time optimization for linear combination myelin imaging

Open access
Vidarsson, Logi, Conolly, Steven M., Lim, Kelvin O., Gold, Garry E., Pauly, John M. · 2005 · Magnetic Resonance in Medicine
Cited by 44

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A 3‐echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal‐to‐noise ratio (SNR) of myelin–water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully optimizing the echo times a 50‐fold tissue water suppression is achieved along with a 10‐fold CSF suppression. For comparison 4, 5, and 32 echo filters are also designed using the same method. The SNR efficiency of these filters is very similar. The 3‐echo filter design was validated by phantom scans. In addition, multislice in vivo myelin images were acquired from both a healthy volunteer and a multiple sclerosis patient. Total scan time was 5 min. A uniform T2 filter is also designed to pass all white matter species with uniform gain. The myelin–water fraction of the in vivo 3‐echo data set is then measured by dividing the myelin image by the uniformly filtered image. Obtained myelin–water fractions compare well with previous work. Magn Reson Med 53:398–407, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20360

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 44

Metadata

Authors
Vidarsson, L., Conolly, S. M., Lim, K. O., Gold, G. E., & Pauly, J. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-01-27
Volume
53
Issue
2
Pages
398-407
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2161771791
Cited by
44
References
3
FWCI
4.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.