CoChat

In vivo method for correcting transmit/receive nonuniformities with phased array coils

Wang, Jinghua, Qiu, Maolin, Constable, R. Todd · 2005 · Magnetic Resonance in Medicine
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Phased array coils are finding widespread applications in both the research and the clinical setting. However, intensity nonuniformities with such coils can reduce the potential benefits of these coils, particularly for applications such as tissue segmentation. In this work, a method is described for correcting the nonuniform signal response based on in vivo measures of both the transmission field of body coil and the reception sensitivity of phased array coils, separately. For a uniform phantom, the reception sensitivity can be calculated using both Bloch equations and transmission field maps. For a heterogeneous object such as a brain, a minimal contrast acquisition must be obtained to map the receiver nonuniformities. This transmit field/receiver sensitivity (TFRS) approach is compared with the standard methods of using the body coil to obtain a reference scan and low‐pass filtering. The quantitative comparison results shows that the TFRS approach provides superior results in correcting intensity nonuniformities for a uniform phantom. This approach reduces the ratio between signal intensity SD of an image and its mean intensity from approximately 21% before correction to 13% after correction. Results are also shown demonstrating the utility of this approach in vivo with human brain images. The method is general and can be applied with most pulse sequences, any coil combination for transmission and reception, and in any anatomic region. Magn Reson Med 53:666–674, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20377

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 111

Metadata

Authors
Wang, J., Qiu, M., & Constable, R. T.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-02-18
Volume
53
Issue
3
Pages
666-674
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2041415171
Cited by
111
References
1
FWCI
5.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.