In vivo method for correcting transmit/receive nonuniformities with phased array coils
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Phased array coils are finding widespread applications in both the research and the clinical setting. However, intensity nonuniformities with such coils can reduce the potential benefits of these coils, particularly for applications such as tissue segmentation. In this work, a method is described for correcting the nonuniform signal response based on in vivo measures of both the transmission field of body coil and the reception sensitivity of phased array coils, separately. For a uniform phantom, the reception sensitivity can be calculated using both Bloch equations and transmission field maps. For a heterogeneous object such as a brain, a minimal contrast acquisition must be obtained to map the receiver nonuniformities. This transmit field/receiver sensitivity (TFRS) approach is compared with the standard methods of using the body coil to obtain a reference scan and low‐pass filtering. The quantitative comparison results shows that the TFRS approach provides superior results in correcting intensity nonuniformities for a uniform phantom. This approach reduces the ratio between signal intensity SD of an image and its mean intensity from approximately 21% before correction to 13% after correction. Results are also shown demonstrating the utility of this approach in vivo with human brain images. The method is general and can be applied with most pulse sequences, any coil combination for transmission and reception, and in any anatomic region. Magn Reson Med 53:666–674, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
B1 mapping by Bloch‐Siegert shift
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22357 · Cited by 529
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
“A variety of B1+ mapping methods have been proposed (Akoka et al., 1993; Helms et al., 2008c; Insko and Bolinger, 1993; Jiru and Klose, 2006; Sacolick et al., 2010; Sled and Pike, 1998, 2000; Wang et al., 2005; Yarnykh, 2007) and some of them systematically compared (Lutti et al., 2010).”
Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout
Chung, S., Kim, D., Breton, E., & Axel, L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22423 · Cited by 304
DREAM—a novel approach for robust, ultrafast, multislice B1 mapping
Nehrke, K., & Börnert, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24158 · Cited by 282
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Perthen, J. E., Lansing, A. E., Liau, J., Liu, T. T., & Buxton, R. B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.049 · Cited by 162
Tarumi, T., Shah, F., Tanaka, H., & Haley, A. P. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.101 · Cited by 108
Metadata
- Authors
- Wang, J., Qiu, M., & Constable, R. T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-02-18
- Volume
- 53
- Issue
- 3
- Pages
- 666-674
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2041415171
- Cited by
- 111
- References
- 1
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.