Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi‐echo VASO fMRI at 1.5 and 3.0 T
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Quantitative interpretation of BOLD fMRI signal changes has predominantly employed empirical models for the whole parenchyma and a calibration step is usually needed to determine the physiological parameters during activation. Although analytical expressions are available for the extravascular and intravascular components of the BOLD effects, it is difficult to experimentally separate tissue from blood signal contributions at the low magnetic fields in which most fMRI studies are performed. Even if this can be achieved, an additional problem that remains is the separation of two types of extravascular BOLD effects, namely those around microvasculature (in the parenchyma close to the site of activation) and those around draining macrovasculature (e.g., in tissue and CSF more remote from the site of activation). In the recently developed vascular space occupancy technique, blood signals are nulled and the activations are localized predominantly in gray matter, allowing experimental measurement of parenchymal extravascular R2* and its changes accompanying activation. When comparing such data with total parenchymal R2* changes in BOLD fMRI, the extravascular fractions were found to be 47 ± 7% (mean ± SEM, n = 4) and 67 ± 6% at 1.5 and 3.0 T, respectively, in line with expectations that intravascular BOLD contributions are reduced at higher field. The present approach provides a noninvasive means to determine parenchymal oxygen extraction fraction (OEF) in situ. During visual stimulation, OEF values measured at 1.5 and 3.0 T were in good agreement, giving 0.23 ± 0.01 and 0.21 ± 0.01, respectively. Magn Reson Med 53:808–816, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796 · cited 1×
“0 T, respectively, are in reasonable agreement with PET and MRI literature results using similar stimuli (18,35), which show a 31–33% decrease in OEF upon activation.”
ResultOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 2×
“0 T, in agreement with predictions in the literature based on reduction of the intravascular venous and venular components with higher field (1).”
BackgroundResultDynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448 · cited 2×
“5 T (15,38), but at high field the value will become smaller due to more dominant extravascular component (23).”
BackgroundDiffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208 · cited 1×
“However, the extent of vascular signal suppression in this approach depends on the vessel sizes and orientations (5,19,21,22) and it can be calculated that remaining microvascular blood signal is substantial.”
Background
Cited by
Krohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
Uludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450
“…Haacke et al., 2005; Jin et al., 2006; Jochimsen et al., 2004; Keilholz et al., 2006; Lee et al., 1999, 2002; Li et al., 2006; Lu et al., 2007; Lu and van Zijl, 2005; Mitsumori et al., 2007; Peters et al., 2007; Ramani et al., 2006; Spees et al., 2001; Stanisz et al., 2005; Weigel and Hennig,…”
MethodInfluentialComparing hemodynamic models with DCM
Stephan, K. E., Weiskopf, N., Drysdale, P. M., Robinson, P. A., & Friston, K. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.040 · Cited by 441
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Lu, H., & Ge, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21627 · Cited by 360
Self-citationDetection of the Ischemic Penumbra Using pH-Weighted MRI
Sun, P. Z., Zhou, J., Sun, W., Huang, J., & van Zijl, P. C. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600424 · Cited by 334
Self-citation
Metadata
- Authors
- Lu, H., & van Zijl, P. C. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-03-29
- Volume
- 53
- Issue
- 4
- Pages
- 808-816
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2002051532
- Cited by
- 114
- References
- 6
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi‐echo VASO fMRI at 1.5 and 3.0 T. https://app.cochat.ai/papers/10.1002/mrm.20379
- The paper
- Lu, H., & van Zijl, P. C. M. (2005). Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi‐echo VASO fMRI at 1.5 and 3.0 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.