Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Single‐shot 3D imaging techniques improve arterial spin labeling perfusion measurements

Günther, Matthias, Oshio, Koichi, Feinberg, David A.·2005·Magnetic Resonance in Medicine

Abstract

Arterial spin labeling (ASL) can be used to measure perfusion without the use of contrast agents. Due to the small volume fraction of blood vessels compared to tissue in the human brain (typ. 3–5%) ASL techniques have an intrinsically low signal‐to‐noise ratio (SNR). In this publication, evidence is presented that the SNR can be improved by using arterial spin labeling in combination with single‐shot 3D readout techniques. Specifically, a single‐shot 3D‐GRASE sequence is presented, which yields a 2.8‐fold increase in SNR compared to 2D EPI at the same nominal resolution. Up to 18 slices can be acquired in 2 min with an SNR of 10 or more for gray matter perfusion. A method is proposed to increase the reliability of perfusion quantification using QUIPSS II derivates by acquiring low‐resolution maps of the bolus arrival time, which allows differentiation between lack of perfusion and delayed arrival of the labeled blood. For arterial spin labeling, single‐shot 3D imaging techniques are optimal in terms of efficiency and might prove beneficial to improve reliability of perfusion quantitation in a clinical setup. Magn Reson Med 54:491–498, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20580

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 293

Metadata

Authors
Günther, M., Oshio, K., & Feinberg, D. A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-07-19
Volume
54
Issue
2
Pages
491-498
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2083749822
Cited by
293
References
10
FWCI
3.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.