Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
Abstract
„Vascular”︁ artifacts can have substantial effects on human cerebral blood flow values calculated by using arterial spin tagging approaches. One vascular artifact arises from the contribution of „tagged”︁ arterial water spins to the observed change in brain water MR signal. This artifact can be reduced if large bipolar gradients are used to „crush”︁ the MR signal from moving arterial water spins. A second vascular artifact arises from relaxation of „tagged”︁ arterial blood during transit from the tagging plane to the capillary exchange site in the imaging slice. This artifact can be corrected if the arterial transit times are measured by using „dynamic”︁ spin tagging approaches. The mean transit time from the tagging plane to capillary exchange sites in a gray matter region of interest was calculated to be ∼0.94 s. Cerebral blood flow values calculated for seven normal volunteers agree reasonably well with values calculated by using radioactive tracer approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Magnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
What is the Correct Value for the Brain-Blood Partition Coefficient for Water?
Herscovitch, P., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.9 · Cited by 705
Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography.
Mintun, M. A., Raichle, M. E., Martin, W. R. W., & Herscovitch, P. (1984) · PubMed · Cited by 608
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
Tissue specific perfusion imaging using arterial spin labeling
Detre, J. A., Zhang, W., Roberts, D. A., Silva, A. C., Williams, D. S., Grandis, D. J., Koretsky, A. P., & Leigh, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070112 · Cited by 335
Bachelard, H. S. (1978) · Trends in Neurosciences · doi:10.1016/0166-2236(78)90169-8 · Cited by 301
Projection angiograms of blood labeled by adiabatic fast passage
Dixon, W. T., Du, L. N., Faul, D. D., Gado, M., & Rossnick, S. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030311 · Cited by 282
Cited by
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Ye, F. Q., Berman, K. F., Ellmore, T., Esposito, G., van Horn, J. D., Yang, Y., Duyn, J., Smith, A. M., Frank, J. A., Weinberger, D. R., et al. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<450::aid-mrm16>3.0.co;2-0 · Cited by 317
Self-citationModel‐free arterial spin labeling quantification approach for perfusion MRI
Petersen, E. T., Lim, T., & Golay, X. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20784 · Cited by 305
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Metadata
- Authors
- Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-02
- Volume
- 37
- Issue
- 2
- Pages
- 226-235
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2092901704
- Cited by
- 294
- References
- 22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. https://app.cochat.ai/papers/10.1002/mrm.1910370215
- The paper
- Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997). Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910370215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.