B1‐insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast‐passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T. Magn Reson Med, 2006. Published 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903 · cited 2×
“The image was assigned a grade as follows: (1) major artifacts in the observed FOV and the coronary arteries, (2) major artifacts in FOV with minor or none visible in the coronary arteries, and (3) no observed artifacts.”
BackgroundMethodSelf-citationHighly selective and π pulse generation
Silver, M. S., Joseph, R. I., & Hoult, D. I. (1984) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(84)90181-1 · Cited by 515
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448 · cited 3×
“(13) was modified to minimize adverse effects of B1 and B0 field inhomogeneities at higher magnetic field strength.”
BackgroundMethodSafety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436 · cited 1×
“0.5(bloodmuscle) [ 5 ] Special attention was paid to standardize ROI size and placement for better comparison between image sets.”
BackgroundInfluentialImproved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRA
Botnar, R. M., Stuber, M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Circulation · doi:10.1161/01.cir.99.24.3139 · Cited by 425 · cited 3×
“This sequence has been optimized for insensitivity to RF pulse imperfections and off-resonance (13,18) and has been extensively utilized at 1.”
MethodSelf-citationBottomley, P. A., & Andrew, E. R. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/4/006 · Cited by 407 · cited 1×
“The image was assigned a grade as follows: (1) major artifacts in the observed FOV and the coronary arteries, (2) major artifacts in FOV with minor or none visible in the coronary arteries, and (3) no observed artifacts.”
MethodBroadband heteronuclear decoupling
Levitt, M. H., Freeman, R., & Frenkiel, T. (1982) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(82)90124-x · Cited by 394
Coronary arteries: breath-hold MR angiography.
Edelman, R. R., Manning, W. J., Burstein, D., & Paulin, S. (1991) · Radiology · doi:10.1148/radiology.181.3.1947074 · Cited by 361 · cited 1×
“Therefore, T2 Prep may simultaneously support fat saturation, which is important for coronary MRA (16).”
BackgroundStuber, M., Botnar, R. M., Danias, P. G., Sodickson, D. K., Kissinger, K. V., Van Cauteren, M., De Becker, J., & Manning, W. J. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00223-5 · Cited by 320 · cited 2×
“A 2D-selective RF pulse with 12 revolutions in k-space and a beam radius of 15 mm was used for gating and tracking of respiratory motion (32).”
MethodSelf-citationWang, Y., Vidan, E., & Bergman, G. W. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc41751 · Cited by 281 · cited 1×
“6 ms) at the level of the proximal-to-mid right coronary artery (RCA) for visual determination of the most quiescent period was added (33).”
Background“Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms
Etienne, A., Botnar, R. M., van Muiswinkel, A. M., Boesiger, P., Manning, W. J., & Stuber, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10253 · Cited by 266 · cited 2×
“Furthermore, vessel sharpness of the proximal segments of right coronary artery was measured utilizing a Deriche algorithm (35).”
MethodSelf-citationPreliminary report on in vivo coronary MRA at 3 Tesla in humans
Stuber, M., Botnar, R. M., Fischer, S., Lamerichs, R. M. J. N., Smink, J., Harvey, P., & Manning, W. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10240 · Cited by 224
Self-citationLi, D., Paschal, C. B., Haacke, E. M., & Adler, L. P. (1993) · Radiology · doi:10.1148/radiology.187.2.8475281 · Cited by 224
Human cardiac imaging at 3 T using phased array coils
Noeske, R., Seifert, F. C., Rhein, K. H., & Rinneberg, H. H. (2000) · Magnetic Resonance in Medicine · Cited by 167
Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography.
Goldfarb, J. W., & Edelman, R. R. (1998) · Radiology · doi:10.1148/radiology.206.3.9494509 · Cited by 158
Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography
Stuber, M., Botnar, R. M., Danias, P. G., McConnell, M. V., Kissinger, K. V., Yucel, E. K., & Manning, W. J. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199911)10:5<790::aid-jmri25>3.0.co;2-i · Cited by 151
Self-citationUǧurbil, K., Garwood, M., & Bendall, M. R. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90186-7 · Cited by 92
Adiabatic rf pulses: Applications to in vivo NMR
de Graaf, R. A., & Nicolay, K. (1997) · Concepts in Magnetic Resonance · doi:10.1002/(sici)1099-0534(1997)9:4<247::aid-cmr4>3.3.co;2-a · Cited by 84
Uǧurbil, K., Garwood, M., Rath, A. R., & Bendall, M. R. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90133-3 · Cited by 80
Singerman, R. W., Denison, T., Wen, H., & Balaban, R. S. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1996.1073 · Cited by 67
Paetsch, I., Huber, M., Bornstedt, A., Schnackenburg, B., Boesiger, P., Stuber, M., Fleck, E., CAVAGNA, F. M., & Nagel, E. C. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20099 · Cited by 49
Self-citation
Cited by
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
T2 mapping in myocardial disease: a comprehensive review
O’Brien, A. T., Gil, K. E., Varghese, J., Simonetti, O. P., & Zareba, K. M. (2022) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-022-00866-0 · Cited by 224
Metadata
- Authors
- Nezafat, R., Stuber, M., Ouwerkerk, R., Gharib, A. M., Desai, M. Y., & Pettigrew, R. I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-03-14
- Volume
- 55
- Issue
- 4
- Pages
- 858-864
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2141048395
- Cited by
- 177
- References
- 23
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.