The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast
Open accessAbstract
Reducing and continuously varying the flip angle of the refocusing RF pulses in a rapid acquisition with relaxation enhancement (RARE; fast/turbo spin echo) sequence is a useful means of addressing high RF power deposition and modulation transfer function (MTF) distortion due to relaxation. This work presents a streamlined technique to generate a sequence of refocusing flip angles on a per‐prescription basis that produces relatively high SNR and limits blurring in a wide range of materials encountered in vivo. Since the “effective TE” (traditionally defined as the time at which the center of k‐space is sampled) no longer corresponds to the expected amount of spin‐echo T2 contrast due to the mixing of stimulated and spin echoes, a “contrast‐equivalent” TE is defined and experimentally demonstrated that allows annotation of a more accurate effective TE that matches the contrast produced by 180° refocusing. Furthermore, contrast is shown to be manipulable by the addition of magnetization preparation pulse sequence segments, such as T2‐prep, to produce clinically desirable contrast for routine head and body imaging. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronary Angiography with Magnetization‐Prepared T2 Contrast
Brittain, J. H., Hu, B. S., Wright, G. A., Meyer, C. H., Macovski, A., & Nishimura, D. G. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330515 · Cited by 448
Self-citationMultiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10391 · Cited by 244
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10658 · Cited by 123
Stabilization of echo amplitudes in FSE sequences
Leroux, P., & Hinks, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300206 · Cited by 77
Busse, R. F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20056 · Cited by 66
Self-citation
Cited by
Mandell, D. M., Mossa-Basha, M., Qiao, Y., Hess, C. P., Hui, F., Matouk, C., Johnson, M. H., Daemen, M. J. A. P., Vossough, A., Edjlali, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4893 · Cited by 691
Super‐resolution musculoskeletal MRI using deep learning
Chaudhari, A. S., Fang, Z., Kogan, F., Wood, J., Stevens, K. J., Gibbons, E. K., Lee, J. H., Gold, G. E., & Hargreaves, B. A. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27178 · Cited by 406
PROMO: Real‐time prospective motion correction in MRI using image‐based tracking
White, N., Roddey, C., Shankaranarayanan, A., Han, E., Rettmann, D., Santos, J., Kuperman, J., & Dale, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22176 · Cited by 376
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Multi-parametric neuroimaging reproducibility: A 3-T resource study
Landman, B. A., Huang, A. J., Gifford, A., Vikram, D. S., Lim, I. A. L., Farrell, J. A. D., Bogovic, J. A., Hua, J., Chen, M., Jarso, S., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.047 · Cited by 299
Metadata
- Authors
- Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-04-05
- Volume
- 55
- Issue
- 5
- Pages
- 1030-1037
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2118886941
- Cited by
- 335
- References
- 6
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast. https://app.cochat.ai/papers/10.1002/mrm.20863
- The paper
- Busse, R. F., Hariharan, H., Vu, A., & Brittain, J. H. (2006). Fast spin echo sequences with very long echo trains: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.