Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 293

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses

Scheenen, Tom W. J., Klomp, Dennis W. J., Wijnen, Jannie P., Heerschap, Arend · 2008 · Magnetic Resonance in Medicine

Abstract

The chemical shift displacement error (CSDE) is an often‐underestimated problem in slice selection for localized proton spectroscopy at higher fields. With the proposed semi‐localized by adiabatic selective refocusing (LASER) pulse sequence, this problem is dealt with by using RF pulses with bandwidths in the order of 5 kHz. A combination of conventional nonadiabatic slice‐selective excitation of proton spins, together with double slice‐selective refocusing of the spins by two pairs of adiabatic full‐passage (APF) pulses, produces a spin echo in a volume of interest (VOI) at an echo time down to 30 ms. An illustration of the CSDE of conventional point‐resolved spectroscopy (PRESS) and the semi‐LASER sequence is shown with a measurement of the brain of a volunteer at 3T. With one application of the technique to a patient with a glioblastoma multiforme (GBM), its clinical functionality is demonstrated. With sharp selection profiles and a small CSDE, voxels close to the edge of the VOI can also be used for evaluation. With the additional advantage of being relatively insensitive for B1 inhomogeneities, the semi‐LASER technique can be viewed as a superior substitute for conventional PRESS MR spectroscopic imaging (MRSI) at 3T and beyond. Magn Reson Med, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21302

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 293

Metadata

Authors
Scheenen, T. W. J., Klomp, D. W. J., Wijnen, J. P., & Heerschap, A.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-10-29
Volume
59
Issue
1
Pages
1-6
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2035068046
Cited by
293
References
13
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses. https://app.cochat.ai/papers/10.1002/mrm.21302
The paper
Scheenen, T. W. J., Klomp, D. W. J., Wijnen, J. P., & Heerschap, A. (2008). Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.