CoChat

Magnetic nanoparticle labeling of mesenchymal stem cells without transfection agent: Cellular behavior and capability of detection with clinical 1.5 T magnetic resonance at the single cell level

Open access
Hsiao, Jong‐Kai, Tai, Ming‐Fong, Chu, Hung‐Hao, Chen, Shin‐Tai, Li, Hung, Lai, Dar‐Ming, Hsieh, Sung‐Tsang, Wang, Jaw‐Lin, Liu, Hon‐Man · 2007 · Magnetic Resonance in Medicine
Cited by 126

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The purpose of this work was to evaluate the efficacy of labeling human mesenchymal stem cells (hMSCs) by ionic superparamagnetic iron oxide (SPIO) without a transfection agent and verifying its capability to be detected with clinical 1.5 T magnetic resonance (MR) at the single‐cell level. Human hMSCs were incubated for 24 h with an ionic SPIO, Ferucarbotran. The labeling efficiency of hMSCs was determined by iron content measurement spectrophotometrically, and the influence of labeling on cell behavior was ascertained by examination of cell viability using the trypan blue exclusion method, cell proliferation analysis using MTT (3‐(4,5‐Dimethylthiazol‐2‐yl)‐2,5‐diphenyltetrazolium bromide) assay, mitochondrial membrane potential (MMP) change, differentiation capacity, and reactive oxygen species (ROS) production measured by dichlorofluorescein diacetate (DCFDA) fluorescent probe. Labeled hMSCs were scanned under 1.5 T MRI with three‐dimensional (3D) and two‐dimensional (2D) T2‐weighted gradient echo (GRE) pulse sequences. Human hMSC labeling without transfection agent was efficient. The iron content in hMSCs was 23.4 pg Fe/cell. No significant change was found in viability, proliferation, MMP change, ROS production, or differentiation capacity. About 45.2% of the hMSCs could be detected using 1.5 T MRI at the single cell level with 3D GRE and four repetitions. Magn Reson Med 58:717–724, 2007. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21377

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 126

Metadata

Authors
Hsiao, J., Tai, M., Chu, H., Chen, S., Li, H., Lai, D., Hsieh, S., Wang, J., & Liu, H.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2007-09-26
Volume
58
Issue
4
Pages
717-724
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2101172338
Cited by
126
References
6
FWCI
4.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic nanoparticle labeling of mesenchymal stem cells without transfection agent: Cellular behavior and capability of detection with clinical 1.5 T magnetic resonance at the single cell level. https://app.cochat.ai/papers/10.1002/mrm.21377
The paper
Hsiao, J., Tai, M., Chu, H., Chen, S., Li, H., Lai, D., Hsieh, S., Wang, J., & Liu, H. (2007). Magnetic nanoparticle labeling of mesenchymal stem cells without transfection agent: Cellular behavior and capability of detection with clinical 1.5 T magnetic resonance at the single cell level. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21377

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.