Abstract
A novel geometrically adjustable transceiver array system is presented. A key feature of the geometrically adjustable array was the introduction of decoupling capacitors that allow for automatic change in capacitance dependent on neighboring resonant element distance. The 16‐element head array version of such an adjustable coil based on transmission line technology was compared to fixed geometry transmission line arrays (TLAs) of various sizes at 7T. The focus of this comparison was on parallel imaging performance, RF transmit efficiency, and signal‐to‐noise ratio (SNR). Significant gains in parallel imaging performance and SNR were observed for the new coil and attributed to its adjustability and to the design of the individual elements with a three‐sided ground plane. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 5×
“The g-factor was estimated solely based on the sensitivity profiles, which were calculated from the FOV as the ratio of images from individual channels to the rootsum-of-squares image of all channels (36).”
MethodInfluentialRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationKatscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468 · cited 1×
“For the smallest coil sizes, however, B1 shimming using phase adjustments (8) in one or two locations were consistently necessary to correct for local signal voids due to transmit phase cancellation in close proximity to the resonance elements.”
MethodSelf-citationTransmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421 · cited 7×
“2b) was essential to avoid RF peak splitting while allowing for coil size changes (7,29,30,33).”
BackgroundMethodInfluentialSelf-citation9.4T human MRI: Preliminary results
Vaughan, T., DelaBarre, L., Snyder, C., Tian, J., Akgun, C., Shrivastava, D., Liu, W., Olson, C., Adriany, G., Strupp, J., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21073 · Cited by 317
Self-citationIbrahim, T. S., Lee, R., Baertlein, B. A., Abduljalil, A. M., Zhu, H., & Robitaille, P.-M. L. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00404-0 · Cited by 225
Microstrip RF surface coil design for extremely high‐field MRI and spectroscopy
Zhang, X., Ugurbil, K., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1212 · Cited by 199 · cited 1×
“Previously, it has been demonstrated that it is possible to build up to 32-element, cylindrically arranged transmit array head coils based on transmission line elements at ultra high frequencies (9,27,28).”
BackgroundWiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Self-citationEfficient high‐frequency body coil for high‐field MRI
Vaughan, J. T., Adriany, G., Snyder, C., Tian, J., Thiel, T., Bolinger, L., Liu, H., DelaBarre, L. J., & Uǧurbil, K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20177 · Cited by 193
Self-citationCoupling and decoupling theory and its application to the MRI phased array
Lee, R. F., Giaquinto, R. O., & Hardy, C. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10186 · Cited by 184 · cited 2×
“Such arrays achieved sufficient electromagnetic decoupling, avoided resonance peak splitting, and maintained transmit efficiency (7,27,29).”
BackgroundCollins, C. M., Yang, Q., Wang, J. H., Zhang, X., Liu, H., Michaeli, S., Zhu, X. H., Adriany, G., Vaughan, J. T., Anderson, P., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10153 · Cited by 131
Self-citationIn vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet
Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., Oppelt, A., Wittig, R., Duerr, W., & Oppelt, R. (1990) · NMR in Biomedicine · doi:10.1002/nbm.1940030106 · Cited by 119
Spectroscopy and imaging with a 4 tesla whole‐body mr system
Bomsdorf, H., Helzel, T., Kunz, D., Röschmann, P., Tschendel, O., & Wieland, J. (1988) · NMR in Biomedicine · doi:10.1002/nbm.1940010308 · Cited by 110
Lumped‐element planar strip array (LPSA) for parallel MRI
Lee, R. F., Hardy, C. J., Sodickson, D. K., & Bottomley, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10667 · Cited by 48
Application of parallel imaging to fMRI at 7 Tesla utilizing a high 1D reduction factor
Moeller, S., de Moortele, P. V., Goerke, U., Adriany, G., & Uǧurbil, K. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20934 · Cited by 38 · cited 4×
“Here, we present a 16-element decoupled transceiver array that allows for flexibly adjustable coil geometry and additional design changes compared to previously described eightand 16-channel transceiver array coils based on the same transmission line principles (7,9).”
BackgroundMethodInfluentialSelf-citationOptimizing the intrinsic signal‐to‐noise ratio of MRI strip detectors
Kumar, A., & Bottomley, P. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20915 · Cited by 23
Cited by
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
“The measured 1D g-factors in this study are larger than those reported for the geometrically adjustable coil (16,17).”
MethodResultSelf-citationUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationVan de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Self-citation
Metadata
- Authors
- Adriany, G., Van de Moortele, P., Ritter, J., Moeller, S., Auerbach, E. J., Akgün, C., Snyder, C. J., Vaughan, T., & Uğurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-01-24
- Volume
- 59
- Issue
- 3
- Pages
- 590-597
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2115316466
- Cited by
- 198
- References
- 18
- FWCI
- 9.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.