The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Abstract
A method is presented for rapid simultaneous quantification of the longitudinal T1 relaxation, the transverse T2 relaxation, the proton density (PD), and the amplitude of the local radio frequency B1 field. All four parameters are measured in one single scan by means of a multislice, multiecho, and multidelay acquisition. It is based on a previously reported method, which was substantially improved for routine clinical usage. The improvements comprise of the use of a multislice spin‐echo technique, a background phase correction, and a spin system simulation to compensate for the slice‐selective RF pulse profile effects. The aim of the optimization was to achieve the optimal result for the quantification of magnetic resonance parameters within a clinically acceptable time. One benchmark was high‐resolution coverage of the brain within 5 min. In this scan time the measured intersubject standard deviation (SD) in a group of volunteers was 2% to 8%, depending on the tissue (voxel size = 0.8 × 0.8 × 5 mm). As an example, the method was applied to a patient with multiple sclerosis in whom the diseased tissue could clearly be distinguished from healthy reference values. Additionally it was shown that, using the approach of synthetic MRI, both accurate conventional contrast images as well as quantification maps can be generated based on the same scan. Magn Reson Med 60:320–329, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
In vivo measurement of T2 distributions and water contents in normal human brain
Whittall, K. P., Mackay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 793
Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water
Ernst, T., Kreis, R., & Ross, B. D. (1993) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1993.1055 · Cited by 504
Deoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
Insights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347
Quantitative MRI of the Brain: Measuring Changes Caused by Disease
(2003) · Wiley eBooks · doi:10.1002/0470869526 · Cited by 347
Deoni, S. C. L. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21130 · Cited by 236
Novel method for rapid, simultaneous T1, T*2, and proton density quantification
Warntjes, J. B. M., Dahlqvist, O., & Lundberg, P. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21165 · Cited by 219
Self-citationOh, J., Cha, S., Aiken, A. H., Han, E. T., Crane, J. C., Stainsby, J. A., Wright, G. A., Dillon, W. P., & Nelson, S. J. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20335 · Cited by 183
A new method for fast quantitative mapping of absolute water content in vivo
Neeb, H., Zilles, K., & Shah, N. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.063 · Cited by 137
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
B1 mapping by Bloch‐Siegert shift
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22357 · Cited by 529
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Tanenbaum, L. N., Tsiouris, A. J., Johnson, A. N., Naidich, T. P., DeLano, M. C., Melhem, E. R., Quarterman, P., Parameswaran, S. X., Shankaranarayanan, A., Goyen, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5227 · Cited by 296
European Society of Radiology (ESR) (2015) · Insights into Imaging · doi:10.1007/s13244-015-0403-3 · Cited by 59
Theranostic implications of nanotechnology in multiple sclerosis: a future perspective.
Singh, A. V., Khare, M., Gade, W. N., & Zamboni, P. (2012) · Autoimmune Diseases · doi:10.1155/2012/160830 · Cited by 58
MR g-ratio-weighted connectome analysis in patients with multiple sclerosis
Kamagata, K., Zalesky, A., Yokoyama, K., Andica, C., Hagiwara, A., Shimoji, K., Kumamaru, K. K., Takemura, M. Y., Hoshino, Y., Kamiya, K., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50025-2 · Cited by 35
Metadata
- Authors
- Warntjes, J. B. M., Leinhard, O. D., West, J., & Lundberg, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 320-329
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2123328938
- Cited by
- 500
- References
- 20
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.