Assessment of liver viscoelasticity using multifrequency MR elastography
Open accessAbstract
MR elastography (MRE) allows the noninvasive assessment of the viscoelastic properties of human organs based on the organ response to oscillatory shear stress. Shear waves of a given frequency are mechanically introduced and the propagation is imaged by applying motion‐sensitive gradients. An experiment was set up that introduces multifrequency shear waves combined with broadband motion sensitization to extend the dynamic range of MRE from one given frequency to, in this study, four different frequencies. With this approach, multiple wave images corresponding to the four driving frequencies are simultaneously acquired and can be evaluated with regard to the dispersion of the complex modulus over the respective frequency. A viscoelastic model based on two shear moduli and one viscosity parameter was used to reproduce the experimental wave speed and wave damping dispersion. The technique was applied in eight healthy volunteers and eight patients with biopsy‐proven high‐grade liver fibrosis (grade 3–4). Fibrotic liver had a significantly higher (P < 0.01) viscosity (14.4 ± 6.6 Pa · s) and elastic moduli (2.91 ± 0.84 kPa; 4.83 ± 1.77 kPa) than the viscosity (7.3 ± 2.3 Pa · s) and elastic moduli (1.16 ± 0.28 kPa; 1.97 ± 0.30 kPa) of normal volunteers. Multifrequency MRE is well suited for the noninvasive differentiation of normal and fibrotic liver as it allows the measurement of rheologic material properties. Magn Reson Med 60:373–379, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Liver fibrosis – from bench to bedside
Friedman, S. L. (2003) · Journal of Hepatology · doi:10.1016/s0168-8278(02)00429-4 · Cited by 1,780
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
The Phenomenological Theory of Linear Viscoelastic Behavior
Tschoegl, N. W. (1989) · Springer eBooks · doi:10.1007/978-3-642-73602-5 · Cited by 1,328
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Hammel, P., Couvelard, A., O'Toole, D., Ratouis, A., Sauvanet, A., Fléjou, J. F., Degott, C., Belghiti, J., Bernades, P., Valla, D., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102083440604 · Cited by 427
Liver fibrosis: non‐invasive assessment with MR elastography
Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1030 · Cited by 417
Cited by
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
Venkatesh, S. K., Yin, M., & Ehman, R. L. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23731 · Cited by 659
Singh, S., Venkatesh, S. K., Wang, Z., Miller, F. H., Motosugi, U., Low, R. N., Hassanein, T., Asbach, P., Godfrey, E. M., Yin, M., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2014.09.046 · Cited by 547
Self-citationChen, J., Talwalkar, J. A., Yin, M., Glaser, K. J., Sanderson, S. O., & Ehman, R. L. (2011) · Radiology · doi:10.1148/radiol.11101942 · Cited by 432
The impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
Self-citationModel-based elastography: a survey of approaches to the inverse elasticity problem
Doyley, M. M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/3/r35 · Cited by 319
MR-elastography reveals degradation of tissue integrity in multiple sclerosis
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., & Sack, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.018 · Cited by 309
Self-citationQuantitative Elastography Methods in Liver Disease: Current Evidence and Future Directions
Kennedy, P., Wagner, M., Castéra, L., Hong, C. W., Johnson, C. L., Sirlin, C. B., & Taouli, B. (2018) · Radiology · doi:10.1148/radiol.2018170601 · Cited by 271
Singh, S., Venkatesh, S. K., Loomba, R., Wang, Z., Sirlin, C., Chen, J., Yin, M., Miller, F. H., Low, R. N., Hassanein, T., et al. (2016) · European Radiology · doi:10.1007/s00330-015-3949-z · Cited by 252
Self-citationGeneral review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Metadata
- Authors
- Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 373-379
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2037339586
- Cited by
- 264
- References
- 21
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.