The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
DWI of the spinal cord with reduced FOV single‐shot EPI
Abstract
Single‐shot echo‐planar imaging (ss‐EPI) has not been used widely for diffusion‐weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross‐sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long readout duration of the ss‐EPI method. Reduced field‐of‐view (FOV) methods decrease the required readout duration for ss‐EPI, thereby enabling its practical application to imaging of the spine. In this work, a reduced FOV single‐shot diffusion‐weighted echo‐planar imaging (ss‐DWEPI) method is proposed, in which a 2D spatially selective echo‐planar RF excitation pulse and a 180° refocusing pulse reduce the FOV in the phase‐encode (PE) direction, while suppressing the signal from fat simultaneously. With this method, multi slice images with higher in‐plane resolutions (0.94 × 0.94 mm 2 for sagittal and 0.62 × 0.62 mm 2 for axial images) are achieved at 1.5 T, without the need for a longer readout. Magn Reson Med 60:468–473, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
“Squashing peanuts and smashing pumpkins”: How noise distorts diffusion‐weighted MR data
Jones, D. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20283 · Cited by 587
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Self-citationApplications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a review
Horsfield, M. A., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.787 · Cited by 468
Analysis and correction of motion artifacts in diffusion weighted imaging
Anderson, A. W., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320313 · Cited by 393
Correction of motional artifacts in diffusion-weighted MR images using navigator echoes
Ordidge, R. J., Helpern, J. A., Qing, Z. X., Knight, R. A., & Nagesh, V. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92539-9 · Cited by 331
Image reconstruction for echo planar imaging with nonequidistant k‐space sampling
Bruder, H., Fischer, H., Reinfelder, H. ‐., & Schmitt, F. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230211 · Cited by 269
Investigating Cervical Spinal Cord Structure Using Axial Diffusion Tensor Imaging
Wheeler-Kingshott, C. A. M., Hickman, S. J., Parker, G. J. M., Ciccarelli, O., Symms, M. R., Miller, D. H., & Barker, G. J. (2002) · NeuroImage · doi:10.1006/nimg.2001.1022 · Cited by 266
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 244
Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging
Wilm, B. J., Svensson, J., Henning, A., Pruessmann, K. P., Boesiger, P., & Kollias, S. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21167 · Cited by 190
Cited by
Quantitative MRI and spectroscopy of bone marrow
Karampinos, D. C., Ruschke, S., Dieckmeyer, M., Diefenbach, M., Franz, D., Gersing, A. S., Krug, R., & Baum, T. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25769 · Cited by 285
Jones, J. G. A., Cen, S. Y., Lebel, R. M., Hsieh, P. C., & Law, M. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3199 · Cited by 157
Metadata
- Authors
- Saritas, E. U., Cunningham, C. H., Lee, J. H., Han, E. T., & Nishimura, D. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-07-29
- Volume
- 60
- Issue
- 2
- Pages
- 468-473
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2028110903
- Cited by
- 264
- References
- 16
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.