Quantitative magnetization transfer imaging using balanced SSFP
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
It is generally accepted that signal formation in balanced steady‐state free precession (bSSFP) is a simple function of relaxation times and flip angle only. This can be confirmed for fluids, but for more complex substances, magnetization transfer (MT) can lead to a considerable loss of steady‐state signal. Thus, especially in tissues, the analytical description of bSSFP requires a revision to fully take observed effects into account. In the first part of this work, an extended bSSFP signal equation is derived based on a binary spin‐bath model. Based on this new model of bSSFP signal formation, quantitative MT parameters such as the fractional pool size, corresponding magnetization exchange rates, and relaxation times can be explored. In the second part of this work, model parameters are derived in normal appearing human brain. Factors that may influence the quality of the model, such as B1 field inhomogeneities or off‐resonances, are discussed. Overall, good correspondence between parameters derived from two‐pool bSSFP and common quantitative MT models is observed. Short repetition times in combination with high signal‐to‐noise ratios make bSSFP an ideal candidate for the acquisition of high resolution isotropic quantitative MT maps, as for the human brain, within clinically feasible acquisition times. Magn Reson Med 60:691–700, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Cited by
In vivo histology of the myelin g-ratio with magnetic resonance imaging
Stikov, N., Campbell, J. S. W., Stroh, T., Lavelée, M., Frey, S., Novek, J., Nuara, S., Ho, M.-K., Bedell, B. J., Dougherty, R. F., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.023 · Cited by 295
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Slice profile and B1 corrections in 2D magnetic resonance fingerprinting
Ma, D., Coppo, S., Chen, Y., McGivney, D. F., Jiang, Y., Pahwa, S., Gulani, V., & Griswold, M. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26580 · Cited by 172
“Other groups have seen lower T2 values after corrections for stimulated echoes (36), SP (21), magnetization transfer (37), and finite RF pulse effect (38).”
Yarnykh, V. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23224 · Cited by 162
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
“Many groups have shown similar T2 reduction by correcting for stimulated echoes (54), slice profile (27,51), magnetization transfer (55), and finite RF pulse effects (56).”
Harrison, N. A., Cooper, E., Dowell, N. G., Keramida, G., Voon, V., Critchley, H. D., & Cercignani, M. (2015) · Biological Psychiatry · doi:10.1016/j.biopsych.2014.09.023 · Cited by 129
“Although myelin dominates this MT exchange process in central nervous system white matter (40,41), other processes such as inflammation (32,33) and metabolic (42) and pH changes (33,41,43) appear to play an important role in other neuronal structures.”
Janve, V. A., Zu, Z., Yao, S.-Y., Li, K., Zhang, F. L., Wilson, K. J., Ou, X., Does, M. D., Subramaniam, S., & Gochberg, D. F. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.034 · Cited by 119
On the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Acute Changes in Striatal Microstructure Predict the Development of Interferon-Alpha Induced Fatigue
Dowell, N. G., Cooper, E. A., Tibble, J., Voon, V., Critchley, H. D., Cercignani, M., & Harrison, N. A. (2016) · Biological Psychiatry · doi:10.1016/j.biopsych.2015.05.015 · Cited by 74
“qMT data were acquired using the balanced steady-state free precession method (29) with a threedimensional true fast imaging with steady-state precession sequence (matrix 5 256 3 96, slices 5 32, slice thickness 5 5 mm).”
MethodMancini, M., Giulietti, G., Dowell, N., Spanò, B., Harrison, N., Bozzali, M., & Cercignani, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.018 · Cited by 43
“binary spin bath model: Gloor's model (Gloor et al., 2008) for site A, and Ramani's (Ramani et al.”
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Rieger, B., Akçakaya, M., Pariente, J. C., Llufriu, S., Martinez-Heras, E., Weingärtner, S., & Schad, L. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-24920-z · Cited by 39
Metadata
- Authors
- Gloor, M., Scheffler, K., & Bieri, O.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-08-25
- Volume
- 60
- Issue
- 3
- Pages
- 691-700
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1999502628
- Cited by
- 155
- References
- 2
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.