The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Quantitative MR susceptibility mapping using piece‐wise constant regularized inversion of the magnetic field
Open accessAbstract
Magnetic properties characterized by susceptibility and chemical shift linearly modify the local magnetic field experienced by spins. A piece‐wise constant solution using magnetic resonance imaging is found to the challenging inversion problem from field to magnetic properties. The magnetic field shifts were estimated from MR phase images. The MR magnitude images were segmented into many regions of uniform magnetic properties. Standard linear regression using the calculated magnetic field from each region allowed accurate susceptibility quantification. The technique was experimentally validated on a variety of samples including water, vegetable oil, air, Gadolinium, and superparamagnetic iron oxides. Susceptibility was measured with a precision better than 0.1 ppm, in a range of 10 ppm. In vivo feasibility was shown on the forearm for which soft‐tissue, cortical bone, and bone marrow susceptibility, and chemical shift values in good agreement with literature data were obtained. Magn Reson Med 60:1003–1009, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of chemistry and physics
(1930) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(30)91499-8 · Cited by 11,721
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Numerical Methods for Least Squares Problems
Björck, Å. (1996) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971484 · Cited by 3,257
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Self-citationHandbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Jung, C. W., & Jacobs, P. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00024-b · Cited by 622
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Dipolar Sums in the Primitive Cubic Lattices
Cohen, M. H., & Keffer, F. (1955) · Physical Review · doi:10.1103/physrev.99.1128 · Cited by 340
Jung, C. W. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00023-a · Cited by 226
Signal‐to‐noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
Conturo, T. E., & Smith, G. D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150308 · Cited by 205
Magnetic susceptibility measurement of insoluble solids by NMR: Magnetic susceptibility of bone.
Hopkins, J. A., & Wehrli, F. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370404 · Cited by 158
MR susceptometry for measuring global brain oxygen extraction
Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20892 · Cited by 147
Cellular magnetic resonance imaging: current status and future prospects
Arbab, A. S., Liu, W. X., & Frank, J. A. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.4.427 · Cited by 140
Quantifying arbitrary magnetic susceptibility distributions with MR
Li, L. Z., & LEIGH, J. S. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20054 · Cited by 132
Koch, K. M., Papademetris, X., Rothman, D. L., & de Graaf, R. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/24/007 · Cited by 126
Magnetic susceptibility quantification for arbitrarily shaped objects in inhomogeneous fields
Li, L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1276 · Cited by 76
Magnetic Resonance Imaging for the Determination of Magnetic Susceptibility of Materials
Beuf, O., Briguet, A., Lissac, M., & Davis, R. (1996) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1996.0120 · Cited by 68
Susceptibility changes following bolus injections
Albert, M. S., Haung, W., Lee, J. H., Patlak, C. S., & SPRINGER, C. S. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290520 · Cited by 64
Sepulveda, N. G., Thomas, I. M., & Wikswo, J. P. (1994) · IEEE Transactions on Magnetics · doi:10.1109/20.334296 · Cited by 59
Magnetic Resonance Imaging Measurement of Volume Magnetic Susceptibility Using a Boundary Condition
Wang, Z., Li, S., & Haselgrove, J. C. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1873 · Cited by 56
Holt, R. W., Diaz, P. J., Duerk, J. L., & Bellon, E. M. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040612 · Cited by 38
de Munck, J. C., Bhagwandien, R. E., Muller, S. H., Verster, F. C., & van Herk, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538939 · Cited by 30
MRI measurement of hepatic magnetic susceptibility—Phantom validation and normal subject studies
Chu, Z. D., Cohen, A. R., Muthupillai, R., Chung, T., & Wang, Z. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20305 · Cited by 24
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citationde Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Metadata
- Authors
- de Rochefort, L., Brown, R., Prince, M. R., & Wang, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-09-24
- Volume
- 60
- Issue
- 4
- Pages
- 1003-1009
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2096111103
- Cited by
- 293
- References
- 27
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.