The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
In vivo 1H NMR spectroscopy of the human brain at high magnetic fields: Metabolite quantification at 4T vs. 7T
Open accessAbstract
A comprehensive comparative study of metabolite quantification from the human brain was performed on the same 10 subjects at 4T and 7T using MR scanners with identical consoles, the same type of RF coils, and identical pulse sequences and data analysis. Signal‐to‐noise ratio (SNR) was increased by a factor of 2 at 7T relative to 4T in a volume of interest selected in the occipital cortex using half‐volume quadrature radio frequency (RF) coils. Spectral linewidth was increased by 50% at 7T, which resulted in a 14% increase in spectral resolution at 7T relative to 4T. Seventeen brain metabolites were reliably quantified at both field strengths. Metabolite quantification at 7T was less sensitive to reduced SNR than at 4T. The precision of metabolite quantification and detectability of weakly represented metabolites were substantially increased at 7T relative to 4T. Because of the increased spectral resolution at 7T, only one‐half of the SNR of a 4T spectrum was required to obtain the same quantification precision. The Cramér‐Rao lower bounds (CRLB), a measure of quantification precision, of several metabolites were lower at both field strengths than the intersubject variation in metabolite concentrations, which resulted in a strong correlation between metabolite concentrations of individual subjects measured at 4T and 7T. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
Provencher, S. W. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300604 · Cited by 3,655
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Automatic quantitation of localized in vivo1H spectra with LCModel
Provencher, S. W. (2001) · NMR in Biomedicine · doi:10.1002/nbm.698 · Cited by 1,634
In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., Star?uk, Z., Choi, I.-Y., & Gruetter, R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4<649::aid-mrm2>3.0.co;2-g · Cited by 1,005
Self-citation7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationAutomatic, localized in Vivo adjustment of all first‐and second‐order shim coils
Gruetter, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290613 · Cited by 870
Self-citationThe sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Field mapping without reference scan using asymmetric echo-planar techniques
Gruetter, R., & Tk�?, I. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<319::aid-mrm22>3.0.co;2-1 · Cited by 569
Self-citationPfeuffer, J., Tkáč, I., Provencher, S. W., & Gruetter, R. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1895 · Cited by 469
Self-citationIn vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
Self-citationTkáč, I., Rao, R., Georgieff, M. K., & Gruetter, R. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10497 · Cited by 225
Self-citationSingle‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Resolution Improvements inin Vivo1H NMR Spectra with Increased Magnetic Field Strength
Gruetter, R., Weisdorf, S. A., Rajanayagan, V., Terpstra, M., Merkle, H., Truwit, C. L., Garwood, M., Nyberg, S. L., & Ugurbil, K. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1542 · Cited by 195
Self-citationHighly resolved in vivo 1H NMR spectroscopy of the mouse brain at 9.4 T
Tkáč, I., Henry, P., Andersen, P., Keene, C. D., Low, W. C., & Gruetter, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20184 · Cited by 187
Self-citationMethodology of1H NMR spectroscopy of the human brain at very high magnetic fields
Tkáć, I., & Gruetter, R. (2005) · Applied Magnetic Resonance · doi:10.1007/bf03166960 · Cited by 184
Self-citationA Half-Volume Coil for Efficient Proton Decoupling in Humans at 4 Tesla
Adriany, G., & Gruetter, R. (1997) · Journal of Magnetic Resonance · doi:10.1006/jmre.1997.1113 · Cited by 169
Self-citationBartha, R., Drost, D. J., Menon, R. S., & Williamson, P. (2000) · Magnetic Resonance in Medicine · Cited by 127
Kantarci, K., Reynolds, G., Petersen, R. C., Boeve, B. F., Knopman, D. S., Edland, S. D., Smith, G. E., Ivnik, R. J., Tangalos, E. G., & Jack, C. R. (2003) · PubMed · Cited by 123
Proton echo‐planar spectroscopic imaging of J ‐coupled resonances in human brain at 3 and 4 Tesla
Posse, S., Otazo, R., Caprihan, A., Bustillo, J., Chen, H., Henry, P., Marjańska, M., Gasparovic, C., Zuo, C. S., Magnotta, V. A., et al. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21287 · Cited by 123
Self-citationOtazo, R., Mueller, B. A., Uǧurbil, K., Wald, L. L., & Posse, S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21067 · Cited by 121
Self-citationGonen, O., Gruber, S., Li, B. S. Y., Mlynárik, V., & Moser, E. (2001) · PubMed · Cited by 114
Wang, J., Yang, Q., Zhang, X., Collins, C. M., Smith, M. B. H., Zhu, X., Adriany, G., Uǧurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10197 · Cited by 78
Self-citationInglese, M., Spindler, M., Babb, J. S., et al. (2006) · PubMed · Cited by 40
MR Spectroscopy and Spectroscopic Imaging: Comparing 3.0 T versus 1.5 T
Dydak, U., & Schär, M. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.02.002 · Cited by 27
Cited by
Emerging applications of metabolomics in drug discovery and precision medicine
Wishart, D. S. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.32 · Cited by 1,488
Metabolomics for Investigating Physiological and Pathophysiological Processes
Wishart, D. S. (2019) · Physiological Reviews · doi:10.1152/physrev.00035.2018 · Cited by 1,212
Clinical Proton MR Spectroscopy in Central Nervous System Disorders
Öz, G., Alger, J. R., Barker, P. B., Bartha, R., Bizzi, A., Boesch, C., Bolan, P. J., Brindle, K. M., Cudalbu, C., Dinçer, A., et al. (2014) · Radiology · doi:10.1148/radiol.13130531 · Cited by 660
Self-citationRae, C. D. (2014) · Neurochemical Research · doi:10.1007/s11064-013-1199-5 · Cited by 496
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citation
Metadata
- Authors
- Tkáč, I., Öz, G., Adriany, G., Uğurbil, K., & Gruetter, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-07-09
- Volume
- 62
- Issue
- 4
- Pages
- 868-879
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2168407651
- Cited by
- 364
- References
- 24
- FWCI
- 15.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.