CoChat

T2 measurement in articular cartilage: Impact of the fitting method on accuracy and precision at low SNR

Open access
Raya, José G., Dietrich, Olaf, Horng, Annie, Weber, Jürgen, Reiser, Maximilian F., Glaser, Christian · 2010 · Magnetic Resonance in Medicine
Cited by 163

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal‐to‐noise ratio of images available from clinical examinations. The purpose of this work was to assess the accuracy and precision of the traditional fit methods (linear least‐squares regression and nonlinear fit to an exponential) and two new noise‐corrected fit methods: fit to a noise‐corrected exponential and fit of the noise‐corrected squared signal intensity to an exponential. Accuracy and precision have been analyzed in simulations, in phantom measurements, and in seven repetitive acquisitions of the patellar cartilage in six healthy volunteers. Traditional fit methods lead to a poor accuracy for low T2, with overestimations of the exact T2 up to 500%. The noise‐corrected fit methods demonstrate a very good accuracy for all T2 values and signal‐to‐noise ratio. Even more, the fit to a noise‐corrected exponential results in precisions comparable to the best achievable precisions (Cramér‐Rao lower bound). For in vivo images, the traditional fit methods considerably overestimate T2 near the bone‐cartilage interface. Therefore, using an adequate fit method may substantially improve the sensitivity of T2 to detect pathology in cartilage and change in T2 follow‐up examinations. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22178

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

Metadata

Authors
Raya, J. G., Dietrich, O., Horng, A., Weber, J., Reiser, M. F., & Glaser, C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-10-26
Volume
63
Issue
1
Pages
181-193
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2029723709
Cited by
163
References
34
FWCI
4.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.