T2 measurement in articular cartilage: Impact of the fitting method on accuracy and precision at low SNR
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal‐to‐noise ratio of images available from clinical examinations. The purpose of this work was to assess the accuracy and precision of the traditional fit methods (linear least‐squares regression and nonlinear fit to an exponential) and two new noise‐corrected fit methods: fit to a noise‐corrected exponential and fit of the noise‐corrected squared signal intensity to an exponential. Accuracy and precision have been analyzed in simulations, in phantom measurements, and in seven repetitive acquisitions of the patellar cartilage in six healthy volunteers. Traditional fit methods lead to a poor accuracy for low T2, with overestimations of the exact T2 up to 500%. The noise‐corrected fit methods demonstrate a very good accuracy for all T2 values and signal‐to‐noise ratio. Even more, the fit to a noise‐corrected exponential results in precisions comparable to the best achievable precisions (Cramér‐Rao lower bound). For in vivo images, the traditional fit methods considerably overestimate T2 near the bone‐cartilage interface. Therefore, using an adequate fit method may substantially improve the sensitivity of T2 to detect pathology in cartilage and change in T2 follow‐up examinations. Magn Reson Med, 2010. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
(1972) · Cited by 17,806
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
A method for the solution of certain non-linear problems in least squares
Levenberg, K. (1944) · Quarterly of Applied Mathematics · doi:10.1090/qam/10666 · Cited by 12,359
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Mathematical Analysis of Random Noise
Rice, S. O. (1945) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1945.tb00453.x · Cited by 2,898
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Contributions to Probability and Statistics: Essays in Honor of Harold Hotelling.
David, F. N., Olkin, I., Ghurye, S. G., Hoeffding, W., Madow, W. G., & Mann, H. B. (1961) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2984135 · Cited by 1,914
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Cartilage MRI T2 Relaxation Time Mapping: Overview and Applications
Mosher, T. J., & Dardzinski, B. J. (2004) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-2004-861764 · Cited by 605 · cited 6×
“[1]) in the definition of (S, σ ) (Eq.”
BackgroundInfluentialSignal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Statistical and Computational Methods in Data Analysis
Brandt, S., & Alexanian, M. (1971) · American Journal of Physics · doi:10.1119/1.1986393 · Cited by 478
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
Magic-Angle Effect in Magnetic Resonance Imaging of Articular Cartilage: A Review
XIA, Y. (2000) · Investigative Radiology · doi:10.1097/00004424-200010000-00007 · Cited by 300
Spatial variation in cartilage T2 of the knee
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1150 · Cited by 288
Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., & Schoenberg, S. O. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.02.001 · Cited by 254
Self-citationThe use of power images to perform quantitative analysis on low SNR MR images
Miller, A. J., & Joseph, P. M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90225-3 · Cited by 244
The b matrix in diffusion tensor echo‐planar imaging
Mattiello, J., Basser, P. J., & Le Bihan, D. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370226 · Cited by 239
MR Imaging and T2 Mapping of Femoral Cartilage: In Vivo Determination of the Magic Angle Effect
Mosher, T. J., Smith, H., Dardzinski, B. J., Schmithorst, V. J., & Smith, M. B. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.3.1770665 · Cited by 235
Bastin, M. E., Armitage, P. A., & Marshall, I. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00098-8 · Cited by 188
Criteria for analysis of multicomponent tissue T2 relaxation data
Graham, S. J., Stanchev, P. L., & Bronskill, M. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350315 · Cited by 179
Noise correction for the exact determination of apparent diffusion coefficients at low SNR
Dietrich, O., Heiland, S., & Sartor, K. J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<448::aid-mrm1059>3.0.co;2-w · Cited by 148
Self-citationTransverse relaxation mechanisms in articular cartilage
Mlynárik, V., Szomolányi, P., Toffanin, R., Vittur, F., & Trattnig, S. (2004) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.05.003 · Cited by 138
Optimal Sampling Strategies for the Measurement of Spin–Spin Relaxation Times
Jones, J. A., Hodgkinson, P., Barker, A. L., & Hore, P. J. (1996) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1996.0151 · Cited by 123
Trattnig, S., Mamisch, T. C., Welsch, G. H., Gläser, C., Szomolányi, P., Gebetsroither, S., Stastny, O., Horger, W., Millington, S. A., & Marlovits, S. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000262088.67368.49 · Cited by 118 · cited 1×
“[7], where the derivative of S with respect to the new parameters must be calculated.”
BackgroundWhittall, K. P., MacKay, A. L., & Li, D. K. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1255::aid-mrm23>3.0.co;2-i · Cited by 96
T2 maximum likelihood estimation from multiple spin‐echo magnitude images
Bonny, J.-M., Zanca, M., Boire, J. Y., & Veyre, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360216 · Cited by 88
Incidental magnetization transfer contrast in fast spin‐echo imaging of cartilage
Yao, L., Gentili, A., & Thomas, A. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060132 · Cited by 75
23. Linear Least Squares with Linear Inequality Constraints
(1995) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971217.ch23 · Cited by 70
Multinuclear NMR and microscopic MRI studies of the articular cartilage nanostructure
Shinar, H., & Navon, G. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1068 · Cited by 58 · cited 3×
“[2] has zero mean, but the probability for n2−2σ 2 ≤ 0 is 1 – 1/e ≈0.”
BackgroundInfluentialOptimal time spacings forT2 measurements: monoexponential and biexponential systems
Shrager, R. I., Weiss, G. H., & Spencer, R. G. S. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<297::aid-nbm531>3.0.co;2-a · Cited by 46
Mendlik, T., Faber, S., Weber, J., Hohe, J., Rauch, E., Reiser, M. F., & Gläser, C. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000119196.50924.f3 · Cited by 46
Self-citationRaya, J., Horng, A., Dietrich, O., Weber, J., Dinges, J., Mützel, E., Reiser, M., & Glaser, C. (2009) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-009-0168-0 · Cited by 15
Self-citationCalculating T2 in images from a phased array receiver
Hardy, P., & Andersen, A. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21904 · Cited by 12
Cited by
Baum, T., Joseph, G. B., Karampinos, D. C., Jungmann, P. M., Link, T. M., & Bauer, J. S. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.07.012 · Cited by 196
Quantitative susceptibility mapping of the midbrain in Parkinson's disease
Du, G., Liu, T., Lewis, M. M., Kong, L., Wang, Y., Connor, J., Mailman, R. B., & Huang, X. (2016) · Movement Disorders · doi:10.1002/mds.26417 · Cited by 165
“The precision of the estimated R2* in the midbrain was assessed by Cramer-Rao lower bound analysis, using an analytical formula provided in Raya et al.(22) The Cramer-Rao lower bound of the mean R2* was 0.”
MethodInfluentialQualitative and quantitative ultrashort‐TE MRI of cortical bone
Du, J., & Bydder, G. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2906 · Cited by 159
“Fourth, a noise-correctedmodel based on the Bessel function of the first kind of nth order is used for bi-component fitting with reduced sensitivity to noise (83).”
MethodLiebl, H., Joseph, G., Nevitt, M. C., Singh, N., Heilmeier, U., Subburaj, K., Jungmann, P. M., McCulloch, C. E., Lynch, J. A., Lane, N. E., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-204157 · Cited by 149
Joseph, G. B., Nevitt, M. C., McCulloch, C. E., Neumann, J., Lynch, J. A., Heilmeier, U., Lane, N. E., & Link, T. M. (2018) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2018.04.019 · Cited by 29
Metadata
- Authors
- Raya, J. G., Dietrich, O., Horng, A., Weber, J., Reiser, M. F., & Glaser, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-10-26
- Volume
- 63
- Issue
- 1
- Pages
- 181-193
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2029723709
- Cited by
- 163
- References
- 34
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.