Quantitative assessment of the effects of high‐permittivity pads in 7 Tesla MRI of the brain
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The use of high‐permittivity materials has been shown to be an effective method for increasing transmit and receive sensitivity in areas of low‐signal intensity in the brain at high field. Results in this article show that the use of these materials does not increase the intercoil coupling for a phased array receive coil, does not have any detrimental effects on the B0 homogeneity within the brain, and does not affect the specific absorption rate distribution within the head. Areas of the brain close to the pads exhibit significant increases (>100%) in transmit field efficiency, but areas further away show a less pronounced (∼10%) decrease due to the homogenization of the transmit field and the loss introduced by the dielectric pads. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 1×
“(15) using standard routines in MATLAB (The Mathworks, Natick, MA).”
MethodChrist, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 1×
“EM simulations were performed using a head model (‘‘Duke’’) (17) with appropriate conductivity and dielectric properties assigned to each tissue and a finite-difference time-domain method with commercially available software (xFDTD, Remcom Inc.”
MethodYarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026 · cited 1×
“B1 þ was mapped with a double-time-of-repetition (TR) method (16) and spatial resolution and voxel size of 3 3 4 mm, TR1/TR2/time-to-echo (TE) 1⁄4 30/150/1.”
MethodHigh-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641 · cited 1×
“The quality of susceptibility-weighted images (21) showed no image degradation, and an increase in signal contrast between white and gray matter in areas of the temporal lobe due to increases in the B1 þ field.”
BackgroundPhenomenological Theory of High Permittivity in Fine‐Grained Barium Titanate
BUESSEM, W. R., CROSS, L. E., & GOSWAMI, A. K. (1966) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1966.tb13144.x · Cited by 538
Phenomenological Theory of High Permittivity in Fine‐Grained Barium Titanate
BUESSEM, W. R., CROSS, L. E., & GOSWAMI, A. K. (1992) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1992.tb04362.x · Cited by 446
Collins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260
Sled, J. G., & Pike, G. B. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730409 · Cited by 189 · cited 2×
“The major mechanism for this approach is believed to be the pad reducing the elliptical eccentricity of the patient, as it is well known that the more elliptical the structure the more spatially inhomogeneous the EM field produced by a quadrature body coil (10).”
BackgroundYang, Q., Mao, W., Wang, J., Smith, M. B. H., Lei, H. C., Zhang, X., Uǧurbil, K., & Chen, W. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20603 · Cited by 179 · cited 5×
“Yang et al. (2) have shown recently that a large water bag placed around the head leads to significant increases in sensitivity across the brain at 3 Tesla.”
MethodInfluentialVersluis, M. J., Peeters, J., van Rooden, S., van der Grond, J., van Buchem, M. A., WEBB, A. G., & van Osch, M. J. P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.048 · Cited by 88 · cited 1×
“2 ms) used commonly in studying neurodegenerative diseases due to its sensitivity to diffuse iron deposition (19).”
BackgroundSelf-citationReducing SAR and enhancing cerebral signal‐to‐noise ratio with high permittivity padding at 3 T
Yang, Q., Wang, J., Wang, J., Collins, C. M., Wang, C., & Smith, M. B. H. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22695 · Cited by 77 · cited 2×
“(2) have shown recently that a large water bag placed around the head leads to significant increases in sensitivity across the brain at 3 Tesla.”
BackgroundVersluis, M. J., Kan, H. E., van Buchem, M. A., & WEBB, A. G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22195 · Cited by 57 · cited 1×
“check this, a volume-selective power calibration (18) was performed on a 2 2 2 cm voxel in the center of the brain.”
MethodSelf-citationSnaar, J. E. M., Teeuwisse, W. M., Versluis, M. J., van Buchem, M. A., Kan, H. E., Smith, N. B., & WEBB, A. G. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1638 · Cited by 57 · cited 1×
“In fact, spectroscopic data have suggested that there is a small, but not statistically significant, decrease in the N-acetylaspartate line width in the temporal lobe when using similar dielectric pads (5).”
BackgroundSelf-citationSTRUCTURE OF PEROVSKITE-TYPE COMPOUNDS
Galasso, F. S. (1969) · Elsevier eBooks · doi:10.1016/b978-0-08-012744-6.50005-7 · Cited by 52
Sreenivas, M., Lowry, M., Gibbs, P., Pickles, M. D., & Turnbull, L. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.11.014 · Cited by 32 · cited 5×
“Yang et al. (2) have shown recently that a large water bag placed around the head leads to significant increases in sensitivity across the brain at 3 Tesla.”
BackgroundInfluential
Cited by
Metasurfaces for bioelectronics and healthcare
Li, Z., Tian, X., Qiu, C.-W., & Ho, J. S. (2021) · Nature Electronics · doi:10.1038/s41928-021-00589-7 · Cited by 159
Whole-body somatotopic maps in the cerebellum revealed with 7T fMRI
Boillat, Y., Bazin, P.-L., & van der Zwaag, W. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116624 · Cited by 85
Metadata
- Authors
- Teeuwisse, W. M., Brink, W. M., & Webb, A. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-08-08
- Volume
- 67
- Issue
- 5
- Pages
- 1285-1293
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1987913322
- Cited by
- 225
- References
- 15
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.