Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose: Quantitative T 2‐relaxation‐based contrast has the potential to provide valuable clinical information. Practical T 2‐mapping, however, is impaired either by prohibitively long acquisition times or by contamination of fast multiecho protocols by stimulated and indirect echoes. This work presents a novel postprocessing approach aiming to overcome the common penalties associated with multiecho protocols, and enabling rapid and accurate mapping of T 2 relaxation values. Methods: Bloch simulations are used to estimate the actual echo‐modulation curve (EMC) in a multi–spin‐echo experiment. Simulations are repeated for a range of T 2 values and transmit field scales, yielding a database of simulated EMCs, which is then used to identify the T 2 value whose EMC most closely matches the experimentally measured data at each voxel. Results: T 2 maps of both phantom and in vivo scans were successfully reconstructed, closely matching maps produced from single spin‐echo data. Results were consistent over the physiological range of T 2 values and across different experimental settings. Conclusion: The proposed technique allows accurate T 2 mapping in clinically feasible scan times, free of user‐ and scanner‐dependent variations, while providing a comprehensive framework that can be extended to model other parameters (e.g., T 1, B 1+, B 0, diffusion) and support arbitrary acquisition schemes. Magn Reson Med 73:809–817, 2015. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“incoherent undersampling to shorten the acquisition times, for example, the pioneering works by Doneva et al (35) and the Magnetic Resonance Fingerprinting approach (36), which relies on the incoherency of the undersampling patterns and applies a pattern-recognition algorithm to extract the underlying MR parameters.”
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 1×
“Although the resulting maps may be affected by residual diffusion effects, these are negligible in comparison to the variability of the T2 values in vivo (30), and the maps were therefore used in this study as a baseline reference for the multi-SE maps.”
Cited by
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Slice profile and B1 corrections in 2D magnetic resonance fingerprinting
Ma, D., Coppo, S., Chen, Y., McGivney, D. F., Jiang, Y., Pahwa, S., Gulani, V., & Griswold, M. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26580 · Cited by 172
“Other groups have seen lower T2 values after corrections for stimulated echoes (36), SP (21), magnetization transfer (37), and finite RF pulse effect (38).”
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
“Many groups have shown similar T2 reduction by correcting for stimulated echoes (54), slice profile (27,51), magnetization transfer (55), and finite RF pulse effects (56).”
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Ben‐Eliezer, N., Sodickson, D. K., & Block, K. T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-03-19
- Volume
- 73
- Issue
- 2
- Pages
- 809-817
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1548804022
- Cited by
- 224
- References
- 4
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.