The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling
Open accessAbstract
Purpose: This article introduces a constrained imaging method based on low‐rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory and Methods: A new model‐based imaging method is developed for MRF to reconstruct high‐quality time‐series images and accurate tissue parameter maps (e.g., T1, T2, and spin density maps). Specifically, the proposed method exploits low‐rank approximations of MRF time‐series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time‐series image reconstruction problem to be formulated as a simple linear least‐squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary‐based pattern matching, as in the conventional approach. Results: The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time‐series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time‐series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. Conclusions: The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933–942, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“In MRF, the contrast-weighted image I m ð x Þ can be expressed as (2,3): (2,3,5,6) form the following data model: ; [3] by combining Equation [1] with [2].”
Method
Cited by
Image Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
“For example, by using low-rank reconstruction methods (41,42), the scan time of the 3D MRF scan with the same spatial resolution and tissue coverage can be reduced to only 2.”
Self-citationRieger, B., Akçakaya, M., Pariente, J. C., Llufriu, S., Martinez-Heras, E., Weingärtner, S., & Schad, L. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-24920-z · Cited by 39
Metadata
- Authors
- Zhao, B., Setsompop, K., Adalsteinsson, E., Gagoski, B., Ye, H., Ma, D., Jiang, Y., Ellen Grant, P., Griswold, M. A., & Wald, L. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-04-15
- Volume
- 79
- Issue
- 2
- Pages
- 933-942
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2606182999
- Cited by
- 179
- References
- 1
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling. https://app.cochat.ai/papers/10.1002/mrm.26701
- The paper
- Zhao, B., Setsompop, K., Adalsteinsson, E., Gagoski, B., Ye, H., Ma, D., Jiang, Y., Ellen Grant, P., Griswold, M. A., & Wald, L. L. (2018). Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.26701
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.