Quantitative susceptibility mapping: Report from the 2016 reconstruction challenge
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Purpose: The aim of the 2016 quantitative susceptibility mapping (QSM) reconstruction challenge was to test the ability of various QSM algorithms to recover the underlying susceptibility from phase data faithfully. Methods: Gradient‐echo images of a healthy volunteer acquired at 3T in a single orientation with 1.06 mm isotropic resolution. A reference susceptibility map was provided, which was computed using the susceptibility tensor imaging algorithm on data acquired at 12 head orientations. Susceptibility maps calculated from the single orientation data were compared against the reference susceptibility map. Deviations were quantified using the following metrics: root mean squared error (RMSE), structure similarity index (SSIM), high‐frequency error norm (HFEN), and the error in selected white and gray matter regions. Results: Twenty‐seven submissions were evaluated. Most of the best scoring approaches estimated the spatial frequency content in the ill‐conditioned domain of the dipole kernel using compressed sensing strategies. The top 10 maps in each category had similar error metrics but substantially different visual appearance. Conclusion: Because QSM algorithms were optimized to minimize error metrics, the resulting susceptibility maps suffered from over‐smoothing and conspicuity loss in fine features such as vessels. As such, the challenge highlighted the need for better numerical image quality criteria. Magn Reson Med 79:1661–1673, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationLiu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338 · cited 1×
“x 1⁄4 argmin x jjxjjWTV þ m 2 jjMx xwelljj22; [4]”
Background
Cited by
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Quantitative magnetic resonance imaging towards clinical application in multiple sclerosis
Granziera, C., Wuerfel, J., Barkhof, F., Calabrese, M., De Stefano, N., Enzinger, C., Evangelou, N., Filippi, M., Geurts, J. J. G., Reich, D. S., et al. (2021) · Brain · doi:10.1093/brain/awab029 · Cited by 203
“fine features, as the methods are primarily optimized to minimize error metrics, not improve image quality.(171) Brain QSM measurements performed by using the same algo-”
MethodQuantitative susceptibility mapping using deep neural network: QSMnet
Yoon, J., Gong, E., Chatnuntawech, I., Bilgic, B., Lee, J., Jung, W., Ko, J., Jung, H., Setsompop, K., Zaharchuk, G., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.030 · Cited by 185
“The quantitative metrics, peak signal-to-noise ratio (pSNR), root mean squared error (RMSE), high-frequency error norm (HFEN), and structure similarity index (SSIM), that were used to measure the reconstruction quality of a QSM algorithm (Langkammer et al., 2018) were calculated with the COSMOS QSM map as a reference.”
MethodHametner, S., Endmayr, V., Deistung, A., Palmrich, P., Prihoda, M., Haimburger, E., Menard, C., Feng, X., Haider, T., Leisser, M., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.007 · Cited by 172
“Special care needs to be taken when comparing susceptibility maps reconstructed with different algorithms since the implemented regularization schemes might have dramatic influence on image sharpness and numerical results (Langkammer et al., 2018).”
Matching ex vivo MRI With Iron Histology: Pearls and Pitfalls
De Barros, A., Arribarat, G., Combis, J., Chaynes, P., & Péran, P. (2019) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2019.00068 · Cited by 31
Metadata
- Authors
- Langkammer, C., Schweser, F., Shmueli, K., Kames, C., Li, X., Guo, L., Milovic, C., Kim, J., Wei, H., Bredies, K., Buch, S., Guo, Y., Liu, Z., Meineke, J., Rauscher, A., Marques, J. P., & Bilgic, B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-07-31
- Volume
- 79
- Issue
- 3
- Pages
- 1661-1673
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2741826558
- Cited by
- 183
- References
- 9
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.