CoChat

Quantitative susceptibility mapping: Report from the 2016 reconstruction challenge

Open access
Langkammer, Christian, Schweser, Ferdinand, Shmueli, Karin, Kames, Christian, Li, Xu, Guo, Li, Milovic, Carlos, Kim, Jinsuh, Wei, Hongjiang, Bredies, Kristian, Buch, Sagar, Guo, Yihao, Liu, Zhe, Meineke, Jakob, Rauscher, Alexander, Marques, José P., Bilgic, Berkin · 2018 · Magnetic Resonance in Medicine
Cited by 183

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Purpose: The aim of the 2016 quantitative susceptibility mapping (QSM) reconstruction challenge was to test the ability of various QSM algorithms to recover the underlying susceptibility from phase data faithfully. Methods: Gradient‐echo images of a healthy volunteer acquired at 3T in a single orientation with 1.06 mm isotropic resolution. A reference susceptibility map was provided, which was computed using the susceptibility tensor imaging algorithm on data acquired at 12 head orientations. Susceptibility maps calculated from the single orientation data were compared against the reference susceptibility map. Deviations were quantified using the following metrics: root mean squared error (RMSE), structure similarity index (SSIM), high‐frequency error norm (HFEN), and the error in selected white and gray matter regions. Results: Twenty‐seven submissions were evaluated. Most of the best scoring approaches estimated the spatial frequency content in the ill‐conditioned domain of the dipole kernel using compressed sensing strategies. The top 10 maps in each category had similar error metrics but substantially different visual appearance. Conclusion: Because QSM algorithms were optimized to minimize error metrics, the resulting susceptibility maps suffered from over‐smoothing and conspicuity loss in fine features such as vessels. As such, the challenge highlighted the need for better numerical image quality criteria. Magn Reson Med 79:1661–1673, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.26830

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 183

Metadata

Authors
Langkammer, C., Schweser, F., Shmueli, K., Kames, C., Li, X., Guo, L., Milovic, C., Kim, J., Wei, H., Bredies, K., Buch, S., Guo, Y., Liu, Z., Meineke, J., Rauscher, A., Marques, J. P., & Bilgic, B.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2017-07-31
Volume
79
Issue
3
Pages
1661-1673
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2741826558
Cited by
183
References
9
FWCI
14.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.