The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Open accessAbstract
The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi‐institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application‐specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48–61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Functional connectivity in the resting brain: a network analysis of the default mode hypothesis
Greicius, M. D., Krasnow, B., Reiss, A. L., & Menon, V. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0135058100 · Cited by 6,358
Greicius, M. D., Srivastava, G., Reiss, A. L., & Menon, V. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0308627101 · Cited by 3,684
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 1×
“With the advent of methods such as magnetic resonance fingerprinting (122) and compressed sensing (123,124), quantitative MRI can now be performed in a clinically appropriate timeline; however, quality control with a quantitative MRI phantom is necessary to ensure the accuracy and precision of results.”
MethodComparison of different MRI brain atrophy rate measures with clinical disease progression in AD
Jack, C. R., Shiung, M. M., Gunter, J. L., O’Brien, P. C., Weigand, S. D., Knopman, D. S., Boeve, B. F., Ivnik, R. J., Smith, G. E., Cha, R. H., et al. (2004) · Neurology · doi:10.1212/01.wnl.0000110315.26026.ef · Cited by 827
Self-citationMoffat, B. A., Chenevert, T. L., Lawrence, T. S., Meyer, C. R., Johnson, T. D., Dong, Q., Tsien, C., Mukherji, S., Quint, D. J., Gebarski, S. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501532102 · Cited by 643
Self-citationOne-year Age Changes in MRI Brain Volumes in Older Adults
Resnick, S. M. (2000) · Cerebral Cortex · doi:10.1093/cercor/10.5.464 · Cited by 517
A prospective diffusion tensor imaging study in mild traumatic brain injury
Mayer, A. R., Ling, J., Mannell, M. V., Gasparovic, C., Phillips, J. P., Doezema, D., Reichard, R., & Yeo, R. A. (2010) · Neurology · doi:10.1212/wnl.0b013e3181d0ccdd · Cited by 459 · cited 3×
“Anisotropic diffusion imaging characterizes the path of water molecule diffusion and is used to characterize brain injury (16,17).”
BackgroundOn the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285 · cited 1×
“For example, the B1 map may be used during T1 mapping model fits to correct the desired versus achieved flip angle (47).”
MethodGatehouse, P. D., Rolf, M. P., Graves, M. J., Hofman, M. B., Totman, J., Werner, B., Quest, R. A., Liu, Y., von Spiczak, J., Dieringer, M., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-5 · Cited by 234
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
On behalf of the EUSOBI international Breast Diffusion-Weighted Imaging working group, Baltzer, P., Mann, R. M., Iima, M., Sigmund, E. E., Clauser, P., Gilbert, F. J., Martincich, L., Partridge, S. C., Patterson, A., et al. (2020) · European Radiology · doi:10.1007/s00330-019-06510-3 · Cited by 437
Lekadir, K., Osuala, R., Gallin, C., Lazrak, N., Kushibar, K., Tsakou, G., Aussó, S., Alberich, L. C., Marias, K., Tsiknakis, M., et al. (2021) · arXiv · doi:10.48550/arxiv.2109.09658 · Cited by 58
“The use of a standardised quantitative calibration phantom and a well-recognised and accepted procedure by the medical imaging and radiology community would decrease inter-scanner variability [81, 135].”
Method
Metadata
- Authors
- Keenan, K. E., Ainslie, M., Barker, A. J., Boss, M. A., Cecil, K. M., Charles, C., Chenevert, T. L., Clarke, L., Evelhoch, J. L., Finn, P., Gembris, D., Gunter, J. L., Hill, D. L. G., Jack, C. R., Jackson, E. F., Liu, G., Russek, S. E., Sharma, S. D., Steckner, M., Stupic, K. F., Trzasko, J. D., Yuan, C., & Zheng, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-10-30
- Volume
- 79
- Issue
- 1
- Pages
- 48-61
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2765192152
- Cited by
- 170
- References
- 10
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.