The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
MR fingerprinting Deep RecOnstruction NEtwork (DRONE)
Open accessAbstract
Purpose: Demonstrate a novel fast method for reconstruction of multi‐dimensional MR fingerprinting (MRF) data using deep learning methods. Methods: A neural network (NN) is defined using the TensorFlow framework and trained on simulated MRF data computed with the extended phase graph formalism. The NN reconstruction accuracy for noiseless and noisy data is compared to conventional MRF template matching as a function of training data size and is quantified in simulated numerical brain phantom data and International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom data measured on 1.5T and 3T scanners with an optimized MRF EPI and MRF fast imaging with steady state precession (FISP) sequences with spiral readout. The utility of the method is demonstrated in a healthy subject in vivo at 1.5T. Results: Network training required 10 to 74 minutes; once trained, data reconstruction required approximately 10 ms for the MRF EPI and 76 ms for the MRF FISP sequence. Reconstruction of simulated, noiseless brain data using the NN resulted in a RMS error (RMSE) of 2.6 ms for T 1 and 1.9 ms for T 2. The reconstruction error in the presence of noise was less than 10% for both T 1 and T 2 for SNR greater than 25 dB. Phantom measurements yielded good agreement (R 2 = 0.99/0.99 for MRF EPI T 1/T 2 and 0.94/0.98 for MRF FISP T 1/T 2) between the T 1 and T 2 estimated by the NN and reference values from the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom. Conclusion: Reconstruction of MRF data with a NN is accurate, 300‐ to 5000‐fold faster, and more robust to noise and dictionary undersampling than conventional MRF dictionary‐matching.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
Deep learning in neural networks: an overview
Schmidhuber, J. (2015) · Neural Networks · doi:10.1016/j.neunet.2014.09.003 · Cited by 18,570
TensorFlow: Large-Scale Machine Learning on Heterogeneous Distributed Systems
Abadi, M., Agarwal, A., Barham, P., Brevdo, E., Chen, Z., Citro, C., Corrado, G. S., Davis, A., Dean, J., Devin, M., et al. (2016) · arXiv · doi:10.48550/arxiv.1603.04467 · Cited by 9,408
Extracting and composing robust features with denoising autoencoders
Vincent, P., Larochelle, H., Bengio, Y., & Manzagol, P.-A. (2008) · Proceedings of the 25th international conference on Machine learning - ICML '08 · doi:10.1145/1390156.1390294 · Cited by 7,436
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
The Vanishing Gradient Problem During Learning Recurrent Neural Nets and Problem Solutions
Hochreiter, S. (1998) · International Journal of Uncertainty, Fuzziness and Knowledge-Based Systems · doi:10.1142/s0218488598000094 · Cited by 2,939
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 2×
“The mean6SD T1 and T2 for each tissue compartment are listed in Table 1 and are similar to values obtained from the literature.(1,31)”
MethodResultDeoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
A simulation study of ridge and other regression estimators
Lawless, J. F., & Wang, P. (1976) · Communication in Statistics- Theory and Methods · doi:10.1080/03610927608827353 · Cited by 457
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Weigel, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24619 · Cited by 426
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
SVD Compression for Magnetic Resonance Fingerprinting in the Time Domain
McGivney, D. F., Pierre, E., Ma, D., Jiang, Y., Saybasili, H., Gulani, V., & Griswold, M. A. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2337321 · Cited by 314
Inversion recovery TrueFISP: Quantification of T1, T2, and spin density
Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M., & Haase, A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20058 · Cited by 242
Slice profile and B1 corrections in 2D magnetic resonance fingerprinting
Ma, D., Coppo, S., Chen, Y., McGivney, D. F., Jiang, Y., Pahwa, S., Gulani, V., & Griswold, M. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26580 · Cited by 172
Better than real: Complex-valued neural nets for MRI fingerprinting
Virtue, P., Yu, S. X., & Lustig, M. S. (2017) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2017.8297024 · Cited by 171
Jiang, Y., Ma, D., Keenan, K. E., Stupic, K. F., Gulani, V., & Griswold, M. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26509 · Cited by 156
Cohen, O., Huang, S., McMahon, M. T., Rosen, M. S., & Farrar, C. T. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27221 · Cited by 131
Self-citationLiao, C., Bilgiç, B., Manhard, M. K., Zhao, B., Cao, X., Zhong, J., Wald, L. L., & Setsompop, K. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.030 · Cited by 118
Fast group matching for MR fingerprinting reconstruction
Cauley, S., Setsompop, K., Ma, D., Jiang, Y., Ye, H., Elfar Adalsteinsson, A., Griswold, M. A., & Wald, L. L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25439 · Cited by 113
Multiparametric estimation of brain hemodynamics with MR fingerprinting ASL
Su, P., Mao, D., Liu, P., Li, Y., Pinho, M. C., Welch, B. G., & Lu, H. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26587 · Cited by 100
Multiscale reconstruction for MR fingerprinting
Pierre, E. Y., Ma, D., Chen, Y., Badve, C. A., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25776 · Cited by 99
Algorithm comparison for schedule optimization in MR fingerprinting
Cohen, O., & Rosen, M. S. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.02.010 · Cited by 87
Self-citationRobust sliding‐window reconstruction for Accelerating the acquisition of MR fingerprinting
Cao, X., Liao, C., Wang, Z., Chen, Y., Ye, H., He, H., & Zhong, J. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26521 · Cited by 73
Rieger, B., Zimmer, F., Zapp, J., Weingärtner, S., & Schad, L. R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26561 · Cited by 73
Low rank approximation methods for MR fingerprinting with large scale dictionaries
Yang, M., Ma, D., Jiang, Y., Hamilton, J., Seiberlich, N., Griswold, M. A., & McGivney, D. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26867 · Cited by 69
Ye, H., Ma, D., Jiang, Y., Cauley, S., Du, Y. P., Wald, L. L., Griswold, M. A., & Setsompop, K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25799 · Cited by 59
Transverse relaxation of cerebrospinal fluid depends on glucose concentration
Daoust, A., Dodd, S., Nair, G., Bouraoud, N., Jacobson, S., Walbridge, S., Reich, D. S., & Koretsky, A. P. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.08.001 · Cited by 28
Cohen, O., & Polimeni, J. R. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26889 · Cited by 17
Self-citationComparison of T1 measurement using ISMRM/NIST system phantom | NIST
Keenan, K. E., Stupic, K. F., Boss, M. A., Russek, S. E., Chenevert, T. L., Prasad, P. V., Reddick, W. E., Zheng, J., Hu, P. C., & Jackson, E. F. (2016) · Cited by 15
Cited by
Applications of machine learning in drug discovery and development
Vamathevan, J., Clark, D., Czodrowski, P., Dunham, I., Ferran, E., Lee, G., Li, B., Madabhushi, A., Shah, P., Spitzer, M., et al. (2019) · Nature Reviews Drug Discovery · doi:10.1038/s41573-019-0024-5 · Cited by 3,228
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Deep Magnetic Resonance Image Reconstruction: Inverse Problems Meet Neural Networks
Liang, D., Cheng, J., Ke, Z., & Ying, L. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950557 · Cited by 370
Balki, I., Amirabadi, A., Levman, J., Martel, A. L., Emersic, Z., Meden, B., Garcia-Pedrero, A., Ramirez, S. C., Kong, D., Moody, A. R., et al. (2019) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2019.06.002 · Cited by 299
Hurkmans, C., Bibault, J.-E., Brock, K. K., van Elmpt, W., Feng, M., David Fuller, C., Jereczek-Fossa, B. A., Korreman, S., Landry, G., Madesta, F., et al. (2024) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2024.110345 · Cited by 110
Metadata
- Authors
- Cohen, O., Zhu, B., & Rosen, M. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2018-04-06
- Volume
- 80
- Issue
- 3
- Pages
- 885-894
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2798456213
- Cited by
- 306
- References
- 31
- FWCI
- 21.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.