The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Variability of motor unit discharge and force fluctuations across a range of muscle forces in older adults
Abstract
Variability of motor unit discharge is a likely contributor to the greater force fluctuations observed in old adults at low muscle forces. We sought to determine whether the variability of motor unit discharge rate underlies the fluctuations in force during steady contractions across a range of forces in young (n = 11) and old (n = 14) adults. The coefficient of variation (CV) for discharge rate and force were measured during a force‐matching task as the first dorsal interosseous muscle performed isometric contractions. The recruitment thresholds of the 78 motor units ranged from 0.04% to 34% of maximal voluntary contraction (MVC) force. The CV for discharge rate ranged from 7.6% to 46.2% and was greater (P < 0.05) for old adults (21.5% ± 7.7%) than young adults (17.3% ± 8.1%). Although the CV for force was similar for young and old subjects (2.53% ± 1.6%) across all target forces, it was greater for old adults at the lowest forces. Furthermore, there was a positive relation (r2 = 0.20, P < 0.001) between the CV for force and the CV for discharge rate across the range of recruitment thresholds. This relation was significant for old adults (r2 = 0.30, P < 0.001), but not for young adults (r2 = 0.06, P > 0.05). Thus, the normalized variability (CV) of motor unit discharge was greater in old adults and was related to the amplitude of force fluctuations across a broader range of forces than previously examined. These findings underscore the contribution of variability of motor unit activity to motor output in normal human aging. Muscle Nerve, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signal-dependent noise determines motor planning
Harris, C. M., & Wolpert, D. M. (1998) · Nature · doi:10.1038/29528 · Cited by 2,498
Models of recruitment and rate coding organization in motor-unit pools.
Fuglevand, A. J., Winter, D. A., & Patla, A. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.6.2470 · Cited by 988
Cited by
The aging neuromuscular system and motor performance
Hunter, S. K., Pereira, H. M., & Keenan, K. G. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00475.2016 · Cited by 532
Self-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
Self-citationHigh-yield decomposition of surface EMG signals
Nawab, S. H., Chang, S.-S., & De Luca, C. J. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.092 · Cited by 370
De Luca, C. J., & Hostage, E. C. (2010) · Journal of Neurophysiology · doi:10.1152/jn.01018.2009 · Cited by 326
Variability of quadriceps femoris motor neuron discharge and muscle force in human aging
Welsh, S. J., Dinenno, D. V., & Tracy, B. L. (2007) · Experimental Brain Research · doi:10.1007/s00221-006-0785-z · Cited by 69
Self-citation
Metadata
- Authors
- Tracy, B. L., Maluf, K. S., Stephenson, J. L., Hunter, S. K., & Enoka, R. M.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2005-06-28
- Volume
- 32
- Issue
- 4
- Pages
- 533-540
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2082512652
- Cited by
- 193
- References
- 2
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability of motor unit discharge and force fluctuations across a range of muscle forces in older adults. https://app.cochat.ai/papers/10.1002/mus.20392
- The paper
- Tracy, B. L., Maluf, K. S., Stephenson, J. L., Hunter, S. K., & Enoka, R. M. (2005). Variability of motor unit discharge and force fluctuations across a range of muscle forces in older adults. Muscle & Nerve. https://doi.org/10.1002/mus.20392
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.