The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Acoustic myography: A noninvasive monitor of motor unit fatigue
Open accessAbstract
Acoustic myography is the recording of sounds produced by contracting muscle. These sounds become louder with increasing force of contraction. We have compared muscle sounds with surface EMG to monitor the dissociation of electrical from mechanical events (presumably, the loss of excitation–contraction coupling) which occur with motor unit fatigue. Acoustic signals were amplified using a standard phonocardiograph, recorded on FM magnetic tape, and digitally analyzed. Muscles were examined at rest, with intermittent contractions, and with sustained contractions. We found that with fatigue, the acoustic amplitude decayed, but the surface EMG amplitude did not. With decreased effort, however, the acoustic and the surface EMG amplitudes declined simultaneously. By simultaneously recording acoustic signals and needle EMG, individual motor units were resolved acoustically in two muscles with decreased numbers of motor units and increased motor unit size. Fasciculations also produced acoustic signals, although no acoustic signal has yet been found that correlates with fibrillations. Analysis of acoustic signals from muscle provides a noninvasive method for monitoring motor unit fatigue in vivo. It may also be useful in distinguishing muscle fatigue from decreased volition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Acoustic signals increase in parallel with surface EMG signals during voluntary and evoked contraction, but acoustic amplitude decays with fatigue whereas EMG amplitude does not”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Barry et al., 1985
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
&NA;, &. (1972) · Southern Medical Journal · doi:10.1097/00007611-197204000-00040 · Cited by 542
The relation between force and integrated electrical activity in fatigued muscle
Edwards, R. G., & Lippold, O. C. J. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005558 · Cited by 324
The sounds from single motor units in a contracting muscle
Gordon, G., & Holbourn, A. H. S. (1948) · The Journal of Physiology · doi:10.1113/jphysiol.1948.sp004290 · Cited by 199
Low frequency sounds from sustained contraction of human skeletal muscle
Oster, G. D., & Jaffe, J. S. (1980) · Biophysical Journal · doi:10.1016/s0006-3495(80)85080-6 · Cited by 156
Maton, B. (1981) · European Journal of Applied Physiology · doi:10.1007/bf00423403 · Cited by 109
Parasites that Change the Behavior of their Host
Moore, J. (1984) · Scientific American · doi:10.1038/scientificamerican0584-108 · Cited by 107
Muscle Fatigue Monitor: A Noninvasive Device for Observing Localized Muscular Fatigue
Stulen, F. B., & Luca, C. J. D. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324871 · Cited by 104
Overwork weakness in partially denervated skeletal muscle.
Bennett, R. L., & Knowlton, G. C. (1958) · PubMed · Cited by 102
Frequency analysis of surface EMG to evaluation of muscle fatigue
Sadoyama, T., & Miyano, H. (1981) · European Journal of Applied Physiology · doi:10.1007/bf00422469 · Cited by 100
Research works printed but not linked: 2
- Porter R, 1981, Human Muscle Fatigue and Physiological Mechanisms, 130
- Brozovich FV, 1984, Muscle sounds: Observations with improved transducers, Biophys J, 45, 106a
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepúlveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 311
Orizio, C., Gobbo, M., Diemont, B., Esposito, F., & Veicsteinas, A. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0924-1 · Cited by 260
Muscular sound and force relationship during isometric contraction in man
Orizio, C., Perini, R., & Veicsteinas, A. (1989) · European Journal of Applied Physiology · doi:10.1007/bf02330708 · Cited by 197
Beck, T. W., Housh, T. J., Cramer, J. T., Weir, J. P., Johnson, G. O., Coburn, J. W., Malek, M. H., & Mielke, M. M. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-67 · Cited by 194
Muscle sounds are emitted at the resonant frequencies of skeletal muscle
Barry, D. T., & Cole, N. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55644 · Cited by 193
Self-citationMadeleine, P. (2010) · Acta Physiologica · doi:10.1111/j.1748-1716.2010.02145.x · Cited by 202
The mechanism of low-frequency sound production in muscle
Frangioni, J. V., Kwan-Gett, T. S., Dobrunz, L. E., & McMahon, T. A. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83404-5 · Cited by 178
Noninvasive Estimation of Myosin Heavy Chain Composition in Human Skeletal Muscle
Šimunič, B., Degens, H., Rittweger, J., Narici, M. V., Mekjavić, I. B., & Pišot, R. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821522d0 · Cited by 176
Surface mechanomyogram reflects muscle fibres twitches summation
Orizio, C., Liberati, D., Locatelli, C., Grandis, D. D., & Veicsteinas, A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00063-1 · Cited by 164
Acoustic signals from frog skeletal muscle
Barry, D. T. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83403-3 · Cited by 164
Self-citationMechanomyography and muscle function assessment: A review of current state and prospects
Ibitoye, M. O., Hamzaid, N. A., Zuñiga, J. M., & Wahab, A. K. A. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.04.003 · Cited by 142
(1986) · PubMed · Cited by 137
Self-citationA Piezoresistive Sensor to Measure Muscle Contraction and Mechanomyography
Esposito, D., Andreozzi, E., Fratini, A., Gargiulo, G. D., Savino, S., Niola, V., & Bifulco, P. (2018) · Sensors · doi:10.3390/s18082553 · Cited by 127
Recording sound from human skeletal muscle: Technical and physiological aspects
Bolton, C. F., Parkes, A., Thompson, T., Clark, M. R., & Sterne, C. J. (1989) · Muscle & Nerve · doi:10.1002/mus.880120207 · Cited by 126
Acoustic and surface EMG diagnosis of pediatric muscle disease
Barry, D. T., Gordon, K., & Hinton, G. G. (1990) · Muscle & Nerve · doi:10.1002/mus.880130403 · Cited by 125
Self-citationMartín-Rodríguez, S., Loturco, I., Hunter, A. M., Ruiz, D. R., & Munguía‐Izquierdo, D. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002250 · Cited by 128
Between-day reliability of a method for non-invasive estimation of muscle composition
Šimunič, B. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.04.003 · Cited by 117
Beck, T. W., Housh, T. J., Johnson, G. O., Cramer, J. T., Weir, J. P., Coburn, J. W., & Malek, M. H. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.12.002 · Cited by 116
Yoshitake, Y., & Moritani, T. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00035-2 · Cited by 106
Fluid mechanics of muscle vibrations
Barry, D. T., & Cole, N. M. (1988) · Biophysical Journal · doi:10.1016/s0006-3495(88)83171-0 · Cited by 105
Self-citationSøgaard, K., Blangsted, A. K., Jørgensen, L. V., Madeleine, P., & Sjøgaard, G. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00075-0 · Cited by 102
Mechanical behaviour of condenser microphone in mechanomyography
Watakabe, M., Mita, K., Akataki, K., & Itoh, Y. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344804 · Cited by 100
Sonographic imaging of muscle contraction and fasciculations: A correlation with electromyography
Walker, F. O., Donofrio, P. D., Harpold, G. J., & Ferrell, W. G. (1990) · Muscle & Nerve · doi:10.1002/mus.880130108 · Cited by 99
Blangsted, A. K., Sjøgaard, G., Madeleine, P., Olsen, H. B., & Søgaard, K. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.10.004 · Cited by 99
Time and frequency domain analysis of electromyogram and sound myogram in the elderly
Esposito, F., Veicsteinas, A., Orizio, C., & Malgrati, D. (1996) · European Journal of Applied Physiology · doi:10.1007/bf00357671 · Cited by 99
Shivering and nonshivering thermogenesis in skeletal muscles
Blondin, D. P., & Haman, F. (2018) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63912-7.00010-2 · Cited by 103
Phonomyogram and electromyogram relationships with isometric force reinvestigated in man
Maton, B., Petitjean, M., & Cnockaert, J. C. (1990) · European Journal of Applied Physiology · doi:10.1007/bf00839159 · Cited by 98
Madeleine, P., Farina, D., Merletti, R., & Arendt‐Nielsen, L. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0655-8 · Cited by 95
Madeleine, P., Jørgensen, V., Søgaard, K., Arendt‐Nielsen, L., & Sjøgaard, G. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0578-4 · Cited by 95
Kouzaki, M., Shinohara, M., & Fukunaga, T. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050551 · Cited by 82
Akataki, K., Mita, K., Itoh, K., Suzuki, N., & Watakabe, M. (1996) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199610)19:10 · Cited by 81
Acoustic myography as an indicator of force during sustained contractions of a small hand muscle
Goldenberg, M., Yack, H. J., Cerny, F., & Burton, H. W. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.1.87 · Cited by 81
Esposito, F., Limonta, E., & Cè, E. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1659-4 · Cited by 80
Schaefer, L. V., & Bittmann, F. N. (2017) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-017-0075-z · Cited by 75
Muscle sound and electromyogram spectrum analysis during exhausting contractions in man
Orizio, C., Perini, R., Diemont, B., & Veicsteinas, A. (1992) · European Journal of Applied Physiology · doi:10.1007/bf01466266 · Cited by 75
Zwarts, M. J., & Keidel, M. (1991) · Muscle & Nerve · doi:10.1002/mus.880140810 · Cited by 73
Stokes, M. J., & Dalton, P. A. (1991) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(91)90041-5 · Cited by 72
Weir, J. P., Ayers, K. M., Lacefield, J. F., & Walsh, K. L. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050054 · Cited by 69
Dalton, P. A., & Stokes, M. J. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00868071 · Cited by 67
Acoustic Myography: Applications and Considerations in Measuring Muscle Performance
Stokes, M. J. (1993) · Isokinetics and Exercise Science · doi:10.3233/ies-1993-3101 · Cited by 65
Pervasive Monitoring of Motion and Muscle Activation: Inertial and Mechanomyography Fusion
Woodward, R. B., Shefelbine, S. J., & Vaidyanathan, R. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2715163 · Cited by 64
A comparative study of simultaneous vibromyography and electromyography with active human quadriceps
Zhang, Y., Frank, C., Rangayyan, R. M., & Bell, G. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161336 · Cited by 63
Muscle fatigue measured with evoked muscle vibrations
Barry, D. T., Hill, T., & Im, D. (1992) · Muscle & Nerve · doi:10.1002/mus.880150308 · Cited by 62
Self-citationMotor unit discharge behaviors in stroke patients
Yan, K., Fang, J., & Shahani, B. T. (1998) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199811)21:11 · Cited by 12
Mechanomyographic Parameter Extraction Methods: An Appraisal for Clinical Applications
Ibitoye, M. O., Hamzaid, N. A., Zuñiga, J. M., Hasnan, N., & Wahab, A. (2014) · Sensors · doi:10.3390/s141222940 · Cited by 59
Evetovich, T. K., Housh, T. J., Johnson, G. O., Smith, D. B., Ebersole, K. T., & Perry, S. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199812000-00007 · Cited by 59
Dalton, P. A., & Stokes, M. J. (1993) · Muscle & Nerve · doi:10.1002/mus.880160303 · Cited by 58
Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration
Ouamer, M., Boiteux, M., Petitjean, M., Travens, L., & Salès, A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00132-3 · Cited by 57
Segmenting Mechanomyography Measures of Muscle Activity Phases Using Inertial Data
Woodward, R. B., Stokes, M. J., Shefelbine, S. J., & Vaidyanathan, R. (2019) · Scientific Reports · doi:10.1038/s41598-019-41860-4 · Cited by 56
Effect of moderate dehydration on torque, electromyography, and mechanomyography
Evetovich, T. K., Boyd, J. C., Drake, S., Eschbach, L. C., Magal, M., Soukup, J. T., Webster, M. J., Whitehead, M. T., & Weir, J. P. (2002) · Muscle & Nerve · doi:10.1002/mus.10203 · Cited by 55
Petitjean, M., & Bellemare, F. (1994) · Muscle & Nerve · doi:10.1002/mus.880171011 · Cited by 55
Orizio, C., Solomonow, M., Baratta, R. V., & Veicsteinas, A. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90026-f · Cited by 55
Harrison, A. P. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12417 · Cited by 54
Madeleine, P., & Arendt‐Nielsen, L. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.06.006 · Cited by 54
Technical aspects of mechnomyography recording with piezoelectric contact sensor
Watakabe, M., Itoh, Y., Mita, K., & Akataki, K. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02524423 · Cited by 53
Sánchez‐Sánchez, J., Bishop, D. J., García‐Unanue, J., Ubago‐Guisado, E., Hernando, E., Fernández, J. L., Colino, E., & Gallardo, L. (2018) · Scientific Reports · doi:10.1038/s41598-018-35345-z · Cited by 52
Harriott-Smith, T. G., & Stokes, M. J. (1993) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(93)90024-l · Cited by 52
Comparison of phonomyography, kinemyography and mechanomyography for neuromuscular monitoring
Trager, G., Michaud, G., Deschamps, S., & Hemmerling, T. M. (2006) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03021816 · Cited by 51
Hand gesture recognition with convolutional neural networks for the multimodal UAV control
Ma, Y., Liu, Y., Jin, R., Yuan, X., Sekha, R., Wilson, S., & Vaidyanathan, R. (2017) · Workshop on Research, Education and Development of Unmanned Aerial Systems (RED-UAS) · doi:10.1109/red-uas.2017.8101666 · Cited by 50
Time-frequency analysis of skeletal muscle and cardiac vibrations
Wood, J. C., & Barry, D. T. (1996) · Proceedings of the IEEE · doi:10.1109/5.535246 · Cited by 50
Self-citationMechanomyography and oxygen consumption during incremental cycle ergometry
Stout, J. R., Housh, T. J., Johnson, G. O., Evetovich, T. K., & Smith, D. B. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050262 · Cited by 50
Muscle sounds from evoked twitches in the hand.
Barry, D. T. (1991) · PubMed · Cited by 48
Self-citationSurface mechanomyogram amplitude is not attenuated by intramuscular pressure
Søgaard, K., Orizio, C., & Sjøgaard, G. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1211-5 · Cited by 46
Camic, C. L., Housh, T. J., Zuñiga, J. M., Hendrix, C. R., Bergstrom, H. C., Traylor, D. A., Schmidt, R. J., & Johnson, G. O. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.09.010 · Cited by 45
Tw, B., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., & Malek, M. H. (2004) · PubMed · Cited by 45
Mamaghani, N. K., Shimomura, Y., Iwanaga, K., & Katsuura, T. (2002) · Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science · doi:10.2114/jpa.21.29 · Cited by 44
Comparison of acoustic and electrical signals from erectores spinae muscles
Stokes, I. A. F., Moffroid, M. T., Rush, S., & Haugh, L. D. (1988) · Muscle & Nerve · doi:10.1002/mus.880110409 · Cited by 44
Assessment of muscular fatigue using vibromyography
Herzog, W., Zhang, Y., Vaz, M. A., Guimarães, A. C. S., & Janssen, C. (1994) · Muscle & Nerve · doi:10.1002/mus.880171005 · Cited by 42
Assessment of postexercise muscle soreness by electromyography and mechanomyography
Bajaj, P., Madeleine, P., Sjøgaard, G., & Arendt‐Nielsen, L. (2002) · Journal of Pain · doi:10.1054/jpai.2002.122945 · Cited by 42
Acoustic myography compared to electromyography during isometric fatigue and recovery
Rodriquez, A. A., Agre, J. C., Knudtson, E. R., Cota, Franke, T. M., & Ng, A. V. (1993) · Muscle & Nerve · doi:10.1002/mus.880160212 · Cited by 41
AlZahrani, E. M., Gunasekaran, C., Callaghan, M. J., Gaydecki, P. A., Benítez, D. S., & Oldham, J. A. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.12.007 · Cited by 40
Blangsted, A. K., Vedsted, P., Sjøgaard, G., & Søgaard, K. (2005) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2005.01411.x · Cited by 40
Vibromyographic recording from human muscles with known fibre composition differences.
Mealing, D., Long, G. L., & McCarthy, P. W. (1996) · British Journal of Sports Medicine · doi:10.1136/bjsm.30.1.27 · Cited by 40
The mechanomyography of persons after stroke during isometric voluntary contractions
Hu, X., Tong, R. K., & Li, L. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.01.015 · Cited by 39
Phonomyogram from single motor units during voluntary isometric contraction
Petitjean, M., & Maton, B. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00854981 · Cited by 38
Soundmyogram and EMG cross-spectrum during exhausting isometric contractions in humans
Orizio, C. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90011-7 · Cited by 37
Cescon, C., Madeleine, P., & Farina, D. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0357-4 · Cited by 37
Advances and perspectives of mechanomyography
Krueger, E., Scheeren, E. M., Neto, G. N. N., Button, V. L. D. S. N., & Nohama, P. (2014) · Research on Biomedical Engineering · doi:10.1590/1517-3151.0541 · Cited by 35
Esposito, F., Limonta, E., Cè, E., Gobbo, M., Veicsteinas, A., & Orizio, C. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0877-5 · Cited by 35
Mechanomyographic responses to maximal eccentric isokinetic muscle actions
Smith, D. B., Housh, T. J., Stout, J. R., Johnson, G. O., Evetovich, T. K., & Ebersole, K. T. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.1003 · Cited by 35
Mamaghani, N. K., Shimomura, Y., Iwanaga, K., & Katsuura, T. (2001) · Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science · doi:10.2114/jpa.20.131 · Cited by 35
Mechanomyography is more sensitive than EMG in detecting age-related sarcopenia
Tian, S., Liu, Y., Li, L., Fu, W., & Peng, C.-H. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.034 · Cited by 32
Jaskólska, A., Madeleine, P., Jaskólski, A., Kisiel‐Sajewicz, K., & Arendt‐Nielsen, L. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.04.002 · Cited by 32
Surface EMG and Myosonography in the Detection of Fasciculations: A Comparative Study
Wenzel, S., Herrendorf, G., Scheel, A., Kurth, C., Steinhoff, B. J., & Reimers, C. D. (1998) · Journal of Neuroimaging · doi:10.1111/jon199883148 · Cited by 32
Kimura, T., Hamada, T., Watanabe, T., Maeda, A., Oya, T., & Moritani, T. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1147-9 · Cited by 32
Mañanas, M. Á., Jané, R., Fiz, J. A., Morera, J., & Caminal, P. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.841339 · Cited by 31
Medagedara, M. H., Ranasinghe, A. C., Lalitharatne, T. D., Gopura, R. A. R. C., & Nandasiri, G. K. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00604 · Cited by 29
Sex Differences in Mechanomyographic Responses to Voluntary Isometric Contractions
Nonaka, H., Mita, K., Akataki, K., Watakabe, M., & Itoh, Y. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000227317.31470.16 · Cited by 29
ViT-LLMR: Vision Transformer-based lower limb motion recognition from fusion signals of MMG and IMU
Zhang, H., Yang, K., Cao, G., & Xia, C. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104508 · Cited by 28
Electro and acoustic myography for noninvasive assessment of lumbar paraspinal muscle function
Lee, D., Stokes, M. J., Taylor, R., & Cooper, R. G. (1992) · European Journal of Applied Physiology · doi:10.1007/bf00626281 · Cited by 28
Vedsted, P., Søgaard, K., Blangsted, A. K., Madeleine, P., & Sjøgaard, G. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.06.002 · Cited by 28
Acoustic myography in the assessment of human masseter muscle
L'Estrange, P. R., ROWELL, J., & Stokes, M. J. (1993) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.1993.tb01618.x · Cited by 28
Hendrix, C. R., Housh, T. J., Camic, C. L., Zuñiga, J. M., Johnson, G. O., & Schmidt, R. J. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.006 · Cited by 27
Bichler, E. K., & Celichowski, J. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00025-6 · Cited by 27
The effect of postactivation potentiation on the mechanomyogram
Shima, N., Rice, C. L., Ota, Y., & Yabe, K. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0053-0 · Cited by 26
Malek, M. H., Coburn, J. W., & Tedjasaputra, V. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.04.026 · Cited by 25
Summation of elementary phonomyograms during isometric twitches in humans
Petitjean, M., Maton, B., & Fourment, A. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050371 · Cited by 25
Muscle sound frequencies of the frog are modulated by skeletal muscle tension
Cole, N. M., & Barry, D. T. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80891-4 · Cited by 25
Self-citationSurface electromyography and mechanomyography recording: A new differential composite probe
Gregori, B., Galiè, E., & Accornero, N. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02349974 · Cited by 23
Metadata
- Authors
- Barry, D. T., Geiringer, S. R., & Ball, R. D.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Barry, Daniel T.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1985-03
- Volume
- 8
- Issue
- 3
- Pages
- 189-194
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2096569144
- Cited by
- 208
- References
- 16
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 2 · 2015: 3 · 2014: 5 · 2013: 10 · 2012: 6
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Muscle & Nerve (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- University of Michigan (48109)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Keywords
- mechanomyography, motor unit fatigue, muscle sound, excitation-contraction coupling, surface electromyography, needle electromyography, sustained contraction, motor unit size, fasciculations
- MeSH terms
- Acoustics, Adult, Electromyography, Fatigue, Humans, Motor Neurons, Muscle Contraction, Muscles, Myography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›