The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Acoustic myography: A noninvasive monitor of motor unit fatigue
Open accessAbstract
Acoustic myography is the recording of sounds produced by contracting muscle. These sounds become louder with increasing force of contraction. We have compared muscle sounds with surface EMG to monitor the dissociation of electrical from mechanical events (presumably, the loss of excitation–contraction coupling) which occur with motor unit fatigue. Acoustic signals were amplified using a standard phonocardiograph, recorded on FM magnetic tape, and digitally analyzed. Muscles were examined at rest, with intermittent contractions, and with sustained contractions. We found that with fatigue, the acoustic amplitude decayed, but the surface EMG amplitude did not. With decreased effort, however, the acoustic and the surface EMG amplitudes declined simultaneously. By simultaneously recording acoustic signals and needle EMG, individual motor units were resolved acoustically in two muscles with decreased numbers of motor units and increased motor unit size. Fasciculations also produced acoustic signals, although no acoustic signal has yet been found that correlates with fibrillations. Analysis of acoustic signals from muscle provides a noninvasive method for monitoring motor unit fatigue in vivo. It may also be useful in distinguishing muscle fatigue from decreased volition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Acoustic signals increase in parallel with surface EMG signals during voluntary and evoked contraction, but acoustic amplitude decays with fatigue whereas EMG amplitude does not”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Barry et al., 1985
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
&NA;, &. (1972) · Southern Medical Journal · doi:10.1097/00007611-197204000-00040 · Cited by 542
The relation between force and integrated electrical activity in fatigued muscle
Edwards, R. G., & Lippold, O. C. J. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005558 · Cited by 324
The sounds from single motor units in a contracting muscle
Gordon, G., & Holbourn, A. H. S. (1948) · The Journal of Physiology · doi:10.1113/jphysiol.1948.sp004290 · Cited by 199
Low frequency sounds from sustained contraction of human skeletal muscle
Oster, G. D., & Jaffe, J. S. (1980) · Biophysical Journal · doi:10.1016/s0006-3495(80)85080-6 · Cited by 156
Maton, B. (1981) · European Journal of Applied Physiology · doi:10.1007/bf00423403 · Cited by 109
Parasites that Change the Behavior of their Host
Moore, J. (1984) · Scientific American · doi:10.1038/scientificamerican0584-108 · Cited by 107
Muscle Fatigue Monitor: A Noninvasive Device for Observing Localized Muscular Fatigue
Stulen, F. B., & Luca, C. J. D. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324871 · Cited by 104
Overwork weakness in partially denervated skeletal muscle.
Bennett, R. L., & Knowlton, G. C. (1958) · PubMed · Cited by 102
Frequency analysis of surface EMG to evaluation of muscle fatigue
Sadoyama, T., & Miyano, H. (1981) · European Journal of Applied Physiology · doi:10.1007/bf00422469 · Cited by 100
Research works printed but not linked: 2
- Porter R, 1981, Human Muscle Fatigue and Physiological Mechanisms, 130
- Brozovich FV, 1984, Muscle sounds: Observations with improved transducers, Biophys J, 45, 106a
Cited by
Sorted by citations
Items 101–200 of 205
Keidel, M., & Keidel, W.-D. (1989) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1989.34.5.107 · Cited by 23
Frequency features of mechanomyographic signals of human soleus muscle during quiet standing
Kouzaki, M., & Fukunaga, T. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.008 · Cited by 22
Time‐frequency analysis of mechanomyogram during sustained contractions with muscle fatigue
Itoh, Y., Akataki, K., Mita, K., Watakabe, M., & Itoh, K. (2003) · Systems and Computers in Japan · doi:10.1002/scj.10528 · Cited by 22
Local muscle fatigue: A precursor to RSI?
Valencia, F. (1986) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1986.tb113839.x · Cited by 22
Wrist Movement Characterization by Mechanomyography Technique
Scheeren, E. M., Krueger, E., Neto, G. N. N., Nohama, P., & Button, V. L. D. S. N. (2010) · Journal of Medical and Biological Engineering · Cited by 21
Pitzalis, R. F., Lagomarsino, B., Ceroni, I., Cartocci, N., Ahmad, J., Albanese, G. A., Zenzeri, J., Natali, C. D., Monica, L., Caldwell, D. G., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3578843 · Cited by 19
Mechanomyography Sensors for Muscle Assessment: a Brief Review
Islam, M. A., Sundaraj, K., Ahmad, R. B., Ahamed, N. U., & Ali, A. (2012) · Journal of Physical Therapy Science · doi:10.1589/jpts.24.1359 · Cited by 18
Celichowski, J., Grottel, K., & Bichler, E. K. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050421 · Cited by 18
Acoustic myography, electromyography and bite force in the masseter muscle
Tortopidis, D., Lyons, M. F., & Baxendale, R. H. (1998) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.1998.00338.x · Cited by 18
Two-dimensional spatial error distribution of key tensiomyographic parameters
Šimunič, B. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.05.035 · Cited by 17
TWITCH PARAMETERS IN TRANSVERSAL AND LONGITUDINAL BICEPS BRACHII RESPONSE
Šimunič, B., Križaj, D., Narici, M. V., & Pišot, R. (2010) · Annales Kinesiologiae · Cited by 17
Tsuji, H., Misawa, H., Takigawa, T., Tetsunaga, T., Yamane, K., Oda, Y., & Ozaki, T. (2021) · Scientific Reports · doi:10.1038/s41598-021-81874-5 · Cited by 16
Cochrane, K. C., Housh, T. J., Jenkins, N. D. M., Bergstrom, H. C., Smith, C. M., Hill, E. C., Johnson, G. O., Schmidt, R. J., & Cramer, J. T. (2015) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0144 · Cited by 16
Dzulkifli, M. A., Hamzaid, N. A., Davis, G. M., & Hasnan, N. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00050 · Cited by 16
Acoustic myography of the human quadriceps muscle during intermittent fatiguing activity
Dalton, P. A., Comerford, M., & Stokes, M. J. (1992) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(92)90093-z · Cited by 16
Mechanomyographic and electromyographic muscle responses are related to power
Bodor, M. (1999) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199905)22:5 · Cited by 16
Bartels, E. M., Olsen, J. K., Andersen, E. L., Danneskiold‐Samsøe, B., Bliddal, H., Kristensen, L. E., & Harrison, A. P. (2020) · Current Research in Physiology · doi:10.1016/j.crphys.2020.02.002 · Cited by 15
Malek, M. H., Coburn, J. W., York, R., Ng, J., & Rana, S. R. (2010) · Muscle & Nerve · doi:10.1002/mus.21686 · Cited by 15
A mechanomyographic frequency-based fatigue threshold test
Hendrix, C. R., Housh, T. J., Zuñiga, J. M., Camic, C. L., Mielke, M. M., Johnson, G. O., & Schmidt, R. J. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.11.019 · Cited by 15
Beck, T. W., & von Tscharner, V. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2008.12.001 · Cited by 14
Reza, M. F., Ikoma, K., Chuma, T., & Mano, Y. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.013 · Cited by 13
Evaluation of the Effects of Chiropractic on Static and Dynamic Muscle Variables in Sport Horses
Acutt, E., le Jeune, S. S., & Pypendop, B. H. (2018) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2018.10.016 · Cited by 14
Vaz, M. A., Herzog, W., Zhang, Y., Leonard, T. R., & Nguyen, H. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(96)00023-5 · Cited by 14
Beck, T. W., Housh, T. J., Fry, A. C., Cramer, J. T., Weir, J. P., Schilling, B. K., Falvo, M. J., & Moore, C. A. (2008) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181660f3f · Cited by 13
Classification of muscle fatigue condition using multi-sensors
Sarillee, M., Hariharan, M., Anas, M. N., Omar, M. I., Aishah, M. N., Yogesh, C. K., & Oung, Q. W. (2015) · IEEE International Conference on Control System, Computing and Engineering · doi:10.1109/iccsce.2015.7482184 · Cited by 12
MMG-torque estimation under dynamic contractions
Lei, K. F., Tsai, W., Lin, W., & Lee, M. (2011) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2011.6083774 · Cited by 12
Altered muscle activation in agility dogs performing warm-up exercises: an acoustic myography study
Fuglsang-Damgaard, L. H., Harrison, A. P., & Vitger, A. D. (2020) · Comparative Exercise Physiology · doi:10.3920/cep190076 · Cited by 12
Non-invasive techniques to assess muscle fatigue using biosensors: A review
Sarillee, M., Hariharan, M., Anas, M. N., Omar, M. I., Aishah, M. N., & Oung, Q. W. (2014) · IEEE Control and System Graduate Research Colloquium (ICSGRC) · doi:10.1109/icsgrc.2014.6908719 · Cited by 12
Resting muscle sounds in anesthetized patients
McKay, W. P. S., Gregson, P. H., McKay, B., & Blanchet, T. (1998) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/cjpp-76-4-401 · Cited by 11
Fatigue analysis of the quadriceps femoris muscle based on mechanomyography
Shin, I., Ahn, S., Choi, J., Ryu, J., Park, S., Son, J., & Kim, Y. (2016) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-016-0059-z · Cited by 11
Initial mechanomyographical signals from twitching fibres of human skeletal muscle
Morimoto, S., & Takemori, S. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2007.01743.x · Cited by 11
Muscle‐related differences in mechanomyography–force relationships are model‐dependent
Cooper, M. A., & Herda, T. J. (2013) · Muscle & Nerve · doi:10.1002/mus.23896 · Cited by 10
Phonomyography on Perioperative Neuromuscular Monitoring: An Overview
Dong, Y., & Li, Q. (2022) · Sensors · doi:10.3390/s22072448 · Cited by 10
Lei, K. F., Cheng, S.-C., Lee, M., & Lin, W. (2013) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237213500208 · Cited by 10
Diaphragmatic Fatigue Investigated by Phonomyography
Petitjean, M., Ripart, J., Couture, J., & Bellemare, F. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117004 · Cited by 10
Stock, M. S., Beck, T. W., DeFreitas, J. M., & Dillon, M. A. (2010) · Journal of Sports Sciences · doi:10.1080/02640414.2010.499440 · Cited by 11
Recent advances in wearable biophysical sensors for continuous muscle monitoring
Zheng, R., & Xu, H. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118463 · Cited by 8
Itoh, Y., Akataki, K., & Mita, K. (1997) · The Japanese Journal of Ergonomics · doi:10.5100/jje.33.175 · Cited by 8
Toward Noncontact Muscle Activity Estimation Using FMCW Radar
Tsengwa, K., Paine, S., Nicolls, F., Albertus, Y., & Patel, A. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3472571 · Cited by 7
Kim, T.-K., Shimomura, Y., Iwanaga, K., & Katsuura, T. (2008) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.27.33 · Cited by 7
Effects of lung volume and fatigue on evoked diaphragmatic phonomyogram in normal subjects.
Petitjean, M., Ripart, J., Couture, J., & Bellemare, F. (1996) · Thorax · doi:10.1136/thx.51.7.705 · Cited by 7
Kawamoto, T., & YAMAZAKI, N. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.03.001 · Cited by 6
Sound myogram: time and frequency domain analysis
Orizio, C., Perini, R., & Veicsteinas, A. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1989.96073 · Cited by 6
Ranniger, C. U., Sorenson, E. A., & Akin, D. L. (1995) · doi:10.2514/6.1995-1046 · Cited by 6
Assessment muscle fatigue using statistical study and classification: A review
Sarillee, M., Hariharan, M., Anas, M. N., Omar, M. I., Aishah, M. N., & Oung, Q. W. (2015) · IEEE International Conference on Control System, Computing and Engineering · doi:10.1109/iccsce.2015.7482185 · Cited by 5
Itoh, Y., Akataki, K., & Mita, K. (2000) · Systems and Computers in Japan · doi:10.1002/1520-684x(20001130)31:13 · Cited by 5
Stock, M. S., Beck, T. W., DeFreitas, J. M., & Ye, X. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.6.769 · Cited by 5
Coherence analysis between soundmyogram and electromyogram
Orizio, C., Diemont, B., Bianchi, A. M., Liberati, D., Cerutti, S., & Veicsteinas, A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684275 · Cited by 5
Analysis of vibromyographic and electromyographic signals from sternomastoid muscle in COPD patients
Jané, R., Fiz, J. A., Mañanas, M. Á., Izquierdo, J., Morera, J., & Caminal, P. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1994.412010 · Cited by 5
Wang, S. J., Guan, X., Bai, Y., Chang, B., Shi, J., He, L., & Zhou, Q. (2025) · Scientific Reports · doi:10.1038/s41598-025-21966-8 · Cited by 4
Application of muscle sound to assess muscle tonus of the electrically stimulated muscle for FES
Yamamoto, T., & Takano, H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1994.412011 · Cited by 4
Herda, T. J., & Cooper, M. A. (2013) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.11.012 · Cited by 4
Acoustic- And Surface Electro-myography Of Human Jaw Elevator Muscles
Stiles, R. N., & Pham, D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684277 · Cited by 4
Hand movements analysis with Acoustic Myography Signals
Yacoub, S., Al-Timemy, A. H., Serrestou, Y., & Raoof, K. (2022) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/ic_aset53395.2022.9765920 · Cited by 4
Jané, R., Fiz, J. A., Mañanas, M. Á., Morera, J., & Caminal, P. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579711 · Cited by 4
Study of the Vibromyographic Signal as a Means for Quantifying Muscular Effort
Sarver, J. J., & Seliktar, R. (2000) · Hong Kong Physiotherapy Journal · doi:10.1016/s1013-7025(09)70015-6 · Cited by 3
Carr, J. C., Beck, T. W., Ye, X., & Wages, N. P. (2018) · Physiological Reports · doi:10.14814/phy2.13590 · Cited by 3
Frequency Domain Analysis Of Muscle Sound During Fatigue Of Human Quadriceps
Healing, D., McBride, J. W., & Khan, A. Z. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1990.692248 · Cited by 3
Influence of Knee Joint Angle Change to the Electromyo gram and Mechanomyogram.
MIYAZAKI, J., & ICHIE, M. (2001) · Rigakuryoho Kagaku · doi:10.1589/rika.16.203 · Cited by 3
A MECANOGRAFIA COMO TÉCNICA NÃO-INVASIVA PARA O ESTUDO DA FUNÇÃO MUSCULAR
Vaz, M. A., & Herzog, W. (2007) · Movimento (Porto Alegre) · doi:10.22456/1982-8918.2450 · Cited by 3
Buis, A. W. P., Guarato, F., Law, J., Ralston, Z., & Courtney, A. (2018) · Canadian Prosthetics & Orthotics Journal · doi:10.33137/cpoj.v1i1.30354 · Cited by 3
A composite probe for acoustic and electromyographic recording of muscular activity
Accornero, N., Berardelli, A., & Manfredi, M. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90233-2 · Cited by 3
Saha, D. P. (2013) · VTechWorks (Virginia Tech) · Cited by 3
An Investigation of Acoustic Chamber Design for Recording AMG Signal
Yacoub, S., Al-Timemy, A. H., Serrestou, Y., Milharo, M., & Raoof, K. (2023) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/ic_aset58101.2023.10151275 · Cited by 2
AMG Signals Acquisition Method
Masmoudi, I., Al-Timemy, A. H., Bouzid, S. E., Yacoub, S., & Raoof, K. (2020) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/ic_aset49463.2020.9318283 · Cited by 2
Yeung, S. S., & Evans, O. M. (1998) · Physiotherapy · doi:10.1016/s0031-9406(05)66247-5 · Cited by 2
Morimoto, S., ISHIWATA, C., Miyamoto, N., & Kamo, M. (2009) · 体力科學 · doi:10.7600/jspfsm.58.365 · Cited by 2
Evaluation of quadriceps femoris muscle function using mechanomyography
Yoshihiro, K. A. I., Murata, S., Kogo, H., IKEDA, N., Hiroshi, O. T. A. O., & Yamada, M. (2011) · Japanese Journal of Health Promotion and Physical Therapy · doi:10.9759/hppt.1.61 · Cited by 2
Smith, C. M. (2016) · Lincoln (University of Nebraska) · Cited by 2
Morimoto, S. (2011) · 体力科學 · doi:10.7600/jspfsm.60.207 · Cited by 2
Spectral Biomimetic Technique for Wood Classification Inspired by Human Echolocation
Rojas, J. A. M., Peña, S. V., Hermosilla, J. A., Montero, R. S., Espí, P. L. L., & Rojas, I. M. (2012) · Advances in Acoustics and Vibration · doi:10.1155/2012/378361 · Cited by 2
REPEATABILITY OF MECHANOMYOGRAM (MMG) FROM VOLUNTARY ISOMETRIC CONTRACTION OF BICEPS BRACHII MUSCLES
Akataki, K., Mita, K., & Itoh, Y. (1998) · 体力科學 · doi:10.7600/jspfsm1949.47.489 · Cited by 1
Evaluation of Muscle Activity Using Mechanomyography: a Comparison with Electromyography
Yoshihiro, K. A. I., Murata, S., & Matuo, N. (2009) · Rigakuryoho Kagaku · doi:10.1589/rika.24.925 · Cited by 1
Research on An Method of Muscle Force Prediction Based on Dynamic Fuzzy Neural Network
Du, Y., Yao, W.-X., Wang, H., Xie, P., Qiu, S., Zhang, N., Jin-Ming-Zhang, & Xie, B.-D. (2018) · Chinese Automation Congress · doi:10.1109/cac.2018.8623567 · Cited by 1
Mirgorodsky, V. I., Дорохов, В. Б., Gerasimov, V. V., & Peshin, S. V. (2019) · Human Physiology · doi:10.1134/s0362119719030125 · Cited by 1
Monitoring Neuromuscular Blockade
Brull, S. J., Silverman, D. G., & Naguib, M. (2013) · Elsevier eBooks · doi:10.1016/b978-0-323-11237-6.00015-7 · Cited by 1
Mehdikhani, R., Olyaei, G., Hadian, M. R., Talebian, S., & Shadmehr, A. (2018) · Journal of Modern Rehabilitation · doi:10.32598/jmr.v12.n4.209 · Cited by 1
Noor, A. M., Zakaria, Z., & Norali, A. N. (2021) · Lecture notes in mechanical engineering · doi:10.1007/978-981-16-0866-7_103 · Cited by 1
Inoue, T., Naemura, K., Hosaka, H., & Itao, K. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2000.900663 · Cited by 1
Muscular sound を用いた脳性麻痺患者の筋機能の分析
赤滝, 久., 晋彦, 伊., 勝己, 三., 伸治, 鈴., 誠, 渡., & 厚生, 加. (1992) · 医用電子と生体工学 · doi:10.11239/jsmbe1963.30.200 · Cited by 1
Zhang, Y., Frank, C., Rangayyan, R. M., & BeIl, G. D. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684276 · Cited by 1
Qi, L. (2011) · UCL Discovery (University College London)
Freitas, C. D. L. R., Brentano, M. A., & Vaz, M. A. (2013) · Americanae (AECID Library)
Practical experience obtaining acoustic myographic signals
Tupper, C. N., & Gerhard, G. C. (2003) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.1988.19370
Clinical Applications Of Acoustic Myography
Barry, D. T., & Cole, N. M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684713
Self-citationComportamento do sinal mecanomiográfico em contrações voluntárias e estimuladas eletricamente
Scheeren, E. M. (2011) · Americanae (AECID Library)
Predicting muscle tenderness and composition with acoustic myography
Hoes, J. A. (1990) · ThinkTech (Texas Tech University)
Analysis of Muscle Function of Patients with Cerebral Palsy by Electromyogram and Muscle Sound.
Akataki, K., Kunihiko, I. T. O. H., Mita, K., SUZUKI, N., Watakabe, M., Takahashi, Y., & Itoh, Y. (1994) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrm1963.31.551
Evaluation of isokinetic muscle performance using a novel mechanomyogram sensor
Pourmajidian, M., Padmanatha, Y., Yusoff, H., Wahab, A. K. A., Hasnan, N., Hamzaid, N. A., & Davis, G. M. (2014) · Annual Conference of the International Functional Electrical Stimulation Society (IFESS) · doi:10.1109/ifess.2014.7036760
Acoustic Myography Frequencies Track The Rise Of Skeletal Muscle Tetanic Tension
Cole, N. M., & Barry, D. T. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.684714
Self-citationEVALUATION OF MUSCLE FATIGUE FOR PREVENTING OVERTRAINING
Ichinoseki, N., Kiryu, T., SUGIMOTO, H., & Saitoh, Y. (2000) · Biomechanisms · doi:10.3951/biomechanisms.15.225
WATANABE, S., Kitawaki, T., & Oka, H. (2006) · Biomechanisms · doi:10.3951/biomechanisms.18.209
Detecting Skeletal Muscle Stiffness Using Mechanomyographic Data Elicited by Pressure Pulse Waves
Kawamoto, T., & YAMAZAKI, N. (2012) · Biomechanisms · doi:10.3951/biomechanisms.21.207
Goldberg, G. (1990) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/s1047-9651(18)30753-8
Recording Electromyographic Activity (EMG) from Single Motor Units in Human Subjects
Macefield, V. G. (2019) · CRC Press eBooks · doi:10.1201/9780367810665-8
Real-time local muscle fatigue assessment using synaptic transistors
Pal, M. (2022) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/156001
Kawashima, T., Ishida, H., FUKUHARA, S., Suehiro, T., Yoshimura, Y., & OKADA, H. (2023) · Journal of the Society of Biomechanisms · doi:10.3951/sobim.47.1_63
Metadata
- Authors
- Barry, D. T., Geiringer, S. R., & Ball, R. D.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Barry, Daniel T.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 1985-03
- Volume
- 8
- Issue
- 3
- Pages
- 189-194
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W2096569144
- Cited by
- 208
- References
- 16
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 2 · 2015: 3 · 2014: 5 · 2013: 10 · 2012: 6
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Muscle & Nerve (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Funders
- University of Michigan (48109)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
- Keywords
- mechanomyography, motor unit fatigue, muscle sound, excitation-contraction coupling, surface electromyography, needle electromyography, sustained contraction, motor unit size, fasciculations
- MeSH terms
- Acoustics, Adult, Electromyography, Fatigue, Humans, Motor Neurons, Muscle Contraction, Muscles, Myography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review