Radio frequency coil technology for small‐animal MRI
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
A review of the theory, technology, and use of radio frequency (RF) coils for small‐animal MRI is presented. It includes a brief overview of MR signal‐to‐noise (S/N) analysis and discussions of the various coils commonly used in small‐animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid‐range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2–30 MHz‐m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full‐wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the ‘lift‐off effect’. Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra‐low‐noise preamps based on the enhancement‐mode pseudomorphic high‐electron‐mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“SENSE (sensitivity encoding) and related techniques (71).”
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 1×
“(69) showed that preamps with low input impedance may be used to reduce the resonant current and coupling in surface coils for a particular type of matching network (similar to that shown for passive detuning in Fig.”
MethodThe signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (1976) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(76)90233-x · Cited by 1,132
Mapping of metabolites in whole animals by 31P NMR using surface coils
Ackerman, J. J. H., Grove, T. H., Wong, G. G., Gadian, D. G., & Radda, G. K. (1980) · Nature · doi:10.1038/283167a0 · Cited by 1,005
The signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.018 · Cited by 995
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
Hayes, C. E., Edelstein, W. A., Schenck, J. F., Mueller, O. M., & Eash, M. G. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90257-4 · Cited by 912
TIME DOMAIN ELECTROMAGNETIC FIELD COMPUTATION WITH FINITE DIFFERENCE METHODS
WEILAND, T. (1996) · International Journal of Numerical Modelling: Electronic Networks, Devices and Fields · doi:10.1002/(sici)1099-1204(199607)9:4<295::aid-jnm240>3.0.co;2-8 · Cited by 712 · cited 1×
“The CST software is based on a discretized solution of the integral formulation of Maxwell’s equations; hence, the method is referred to as finite integration technique (FIT) (10).”
MethodCryogenically cooled probes—a leap in NMR technology
Kovacs, H., Moskau, D., & Spraul, M. (2005) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2005.03.001 · Cited by 531 · cited 1×
“diameter for more than six years, and their factor-of-four gain in S/N is revolutionizing the field of NMR (87).”
BackgroundIn Vivo NMR Spectroscopy: Principles and Techniques
de Graaf, R. A. (2019) · Medical Entomology and Zoology · Cited by 504
Cited by
A robust methodology for in vivo T1 mapping
Barral, J. K., Gudmundson, E., Stikov, N., Etezadi‐Amoli, M., Stoica, P., & Nishimura, D. G. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22497 · Cited by 228
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“Further improvements in image quality are to be expected by the implementation of parallel-reception and -transmission techniques, as well as cryo-coils, which are cooled with liquid helium or nitrogen and yield signal-to-noise improvements of approximately a factor of 2, compared with coils operated at room temperatu…”
BackgroundMicro MRI of the mouse brain using a novel 400 MHz cryogenic quadrature RF probe
Baltes, C., Radzwill, N., Bosshard, S., Marek, D., & Rudin, M. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1396 · Cited by 152
Performance of a 200‐MHz cryogenic RF probe designed for MRI and MRS of the murine brain
Ratering, D., Baltes, C., Nordmeyer‐Massner, J., Marek, D., & Rudin, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21629 · Cited by 91
Febo, M. (2011) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2011.00043 · Cited by 43
“Many laboratories construct their own RF coils (Ugurbil et al., 2003; Doty et al., 2007).”
BackgroundMRI of whole rat brain perivascular network reveals role for ventricles in brain waste clearance
Magdoom, K. N., Brown, A., Rey, J., Mareci, T. H., King, M. A., & Sarntinoranont, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-44938-1 · Cited by 35
Metadata
- Authors
- Doty, F. D., Entzminger, G., Kulkarni, J., Pamarthy, K., & Staab, J. P.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2007-04-24
- Volume
- 20
- Issue
- 3
- Pages
- 304-325
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2050362788
- Cited by
- 208
- References
- 28
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.