Micro MRI of the mouse brain using a novel 400 MHz cryogenic quadrature RF probe
Abstract
The increasing number of mouse models of human disease used in biomedical research applications has led to an enhanced interest in non‐invasive imaging of mice, e.g. using MRI for phenotyping. However, MRI of small rodents puts high demands on the sensitivity of data acquisition. This requirement can be addressed by using cryogenic radio‐frequency (RF) detection devices. The aim of this work was to investigate the in vivo performance of a 400 MHz cryogenic transmit/receive RF probe (CryoProbe) designed for MRI of the mouse brain. To characterize this novel probe, MR data sets were acquired with both the CryoProbe and a matched conventional receive‐only surface coil operating at room temperature (RT) using conventional acquisition protocols (gradient and spin echo) with identical parameter settings. Quantitative comparisons in phantom and in vivo experiments revealed gains in the signal‐to‐noise ratio (SNR) of 2.4 and 2.5, respectively. The increased sensitivity of the CryoProbe was invested to enhance the image quality of high resolution structural images acquired in scan times compatible with routine operation (< 45 min). In high resolution (30 × 30 × 300 µm 3) structural images of the mouse cerebellum, anatomical details such as Purkinje cell and molecular layers could be identified. Similarly, isotropic (60 × 60 × 60 µm 3) imaging of mouse cortical and subcortical areas revealed anatomical structures smaller than 100 µm. Finally, 3D MR angiography (52 × 80 × 80 µm 3) of the brain vasculature enabled the detailed reconstruction of intracranial vessels (anterior and middle cerebral artery). In conclusion, this low temperature detection device represents an attractive option to increase the performance of small animal MR systems operating at 9.4 Tesla. Copyright © 2009 John Wiley & Sons, Ltd.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Previous DTI studies assessing microstructural changes in rTg4510 mice produced conflicting results.
“Previous DTI studies assessing microstructural changes in rTg4510 mice, which express transgenic tau P301L mutations driven by a Ca 2+ / calmodulin kinase II promoter system [30,31] in the white and grey matter produced conflicting results [33][34][35][36].”
From Diffusion tensor imaging reveals whole-brain microstructural changes in the P301L mouse model of tauopathy. (2020) · cites this paper as [33]
Effects of tauopathy on DTI metrics in grey and white matter are complex and may involve axonal damage, myelin injury, neuronal degeneration, and gliosis, which all have been found in tauopathies.
“Effects of tauopathy on DTI metrics in the grey and white matter are complex and may involve axonal damage, myelin injury, neuronal degeneration, and gliosis, which all have been found in tauopathies [17,18,23,25,28,29,33,38,57].”
From Diffusion tensor imaging reveals whole-brain microstructural changes in the P301L mouse model of tauopathy. (2020) · cites this paper as [33]
Cites
The Mouse Brain in Stereotaxic Coordinates
Paxinos, G. (2001) · Cited by 12,859 · see citing works
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,088 · see citing works
Hisano, S., Hoshi, K., Ikeda, Y., Maruyama, D., Kanemoto, M., Ichijo, H., Kojima, I., Takeda, J., & Nogami, H. (2000) · Molecular Brain Research · doi:10.1016/s0169-328x(00)00194-7 · Cited by 806 · see citing works
Rapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 382 · see citing works
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357 · see citing works
Rapid Three-Dimensional MR Imaging Using the FLASH Technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198603000-00046 · Cited by 273 · see citing works
Radio frequency coil technology for small‐animal MRI
Doty, F. D., Entzminger, G., Kulkarni, J., et al. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1149 · Cited by 210 · see citing works
A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy
Black, R. D., Early, T. A., Roemer, P. B., et al. (1993) · Science · doi:10.1126/science.8430331 · Cited by 207 · see citing works
Perspectives with cryogenic RF probes in biomedical MRI
Darrasse, L. (2003) · Biochimie · doi:10.1016/j.biochi.2003.09.016 · Cited by 201 · see citing works
Jack, C. R., Garwood, M., Wengenack, T. M., Borowski, B., Curran, G. L., Lin, J., Adriany, G., Gröhn, O. H. J., Grimm, R. C., & Poduslo, J. F. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20266 · Cited by 196 · see citing works
Assaf, Y., & Cohen, Y. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2 · Cited by 184 · see citing works
MR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., et al. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 172 · see citing works
Jack, C. R., Wengenack, T. M., Reyes, D. A., Garwood, M., Curran, G. L., Borowski, B. J., Lin, J., Preboske, G. M., Holasek, S. S., Adriany, G., et al. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2588-05.2005 · Cited by 148 · see citing works
A high-resolution NMR probe in which the coil and preamplifier are cooled with liquid helium
Styles, P., Soffe, N., Scott, C. A., et al. (1984) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(84)90050-7 · Cited by 139 · see citing works
Vanhoutte, G., Dewachter, I., Borghgraef, P., Leuven, F. V., & der Linden, A. V. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20385 · Cited by 137 · see citing works
Diffusion tensor microscopy of the intervertebral disc anulus fibrosus
Hsu, E. W., & Setton, L. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5 · Cited by 127 · see citing works
A high-resolution NMR probe in which the coil and preamplifier are cooled with liquid helium
Styles, P., Soffe, N., Scott, C. A., et al. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.002 · Cited by 126 · see citing works
Petiet, A. E., Kaufman, M. H., Goddeeris, M. M., Brandenburg, J., Elmore, S. A., & Johnson, G. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805747105 · Cited by 120 · see citing works
Performance of a 200‐MHz cryogenic RF probe designed for MRI and MRS of the murine brain
Ratering, D., Baltes, C., Nordmeyer‐Massner, J., Marek, D., & Rudin, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21629 · Cited by 86 · see citing works
Self-citationBraakman, N., Matysik, J., van Duinen, S. G., Verbeek, F. J., Schliebs, R., de Groot, H. J. M., & Alia, A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20675 · Cited by 77 · see citing works
Sawiak, S. J., Wood, N. I., Williams, G. B., Morton, A. J., & Carpenter, T. A. (2008) · Neurobiology of Disease · doi:10.1016/j.nbd.2008.09.017 · Cited by 70 · see citing works
Laurent, D., Wasvary, J. S., Yin, J., et al. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00433-7 · Cited by 70 · see citing works
THE RELATIONSHIP OF BODY SIZE, NERVE CELL SIZE, AXON LENGTH, AND GLIAL DENSITY IN THE CEREBELLUM
Friede, R. L. (1963) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.49.2.187 · Cited by 67 · see citing works
Automated segmentation of the actively stained mouse brain using multi-spectral MR microscopy
Ali-Sharief, A., Badea, A., Dale, A. M., & Johnson, G. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.028 · Cited by 62 · see citing works
Use of high temperature superconductor in a receiver coil for magnetic resonance imaging
Hall, A. S., Alford, N. M., Button, T. W., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200218 · Cited by 59 · see citing works
Poirier‐Quinot, M., Ginéfri, J., Girard, O. M., et al. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21605 · Cited by 50 · see citing works
Magnetization transfer MRI of mouse brain reveals areas of high neural density
Natt, O., Watanabe, T., Boretius, S., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.012 · Cited by 34 · see citing works
Kim, S., Pickup, S., Hsu, O., et al. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1324 · Cited by 30 · see citing works
Ginéfri, J., Poirier‐Quinot, M., Girard, O. M., et al. (2007) · Methods · doi:10.1016/j.ymeth.2007.03.011 · Cited by 30 · see citing works
Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain
Nouls, J. C., Izenson, M. G., Greeley, H. P., et al. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.12.018 · Cited by 29 · see citing works
Progress in high field MRI at the University of Florida
Beck, B. L. (2002) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1016/s1352-8661(01)00140-5 · Cited by 29 · see citing works
Performance of Large-Size Superconducting Coil in 0.21T MRI System
Lee, K. H., Cheng, M.-S., Chan, K. C., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831539 · Cited by 22 · see citing works
Progress in high field MRI at the University of Florida
Beck, B. L., Plant, D. P., Grant, S. C., et al. (2001) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02678590 · Cited by 15 · see citing works
Nuclear magnetic resonance microscopy
VanGorden, S. (1999) · RIT Scholar Works (Rochester Institute of Technology) · Cited by 11 · see citing works
Buckley (1999) · doi:10.1002/(sici)1522-2594(199901)41:1
Flagged first, then by citations
Research works printed but not linked: 2
- RadzwillNI HaueisenR MarekD SacherM JungeS. Benefits of cryogenic coils for routine in‐vivo mouse brain imaging and spectroscopy at 9.4T In:Proceedings of 15th Annual Meeting ISMRM Berlin Germany Abstract: 3267 2007.
- AliaA KabliS GrossD MarekD OertherT SacherM SpainkHP De GrootHM. Magnetic resonance microimaging of adult zebrafish brain using cryoprobe technology. ISMRM. In:Proceedings of 15th Annual Meeting ISMRM Berlin Germany Abstract: 1056 2007.
Cited by
Sorted by citations
Imaging of cerebrovascular pathology in animal models of Alzheimer's disease
Klohs, J., Rudin, M., Shimshek, D. R., & Beckmann, N. (2014) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2014.00032 · Cited by 82 · see citing works
Self-citationStructural insights into the rodent CNS via diffusion tensor imaging.
Zhang, J., Aggarwal, M., & Mori, S. (2012) · Trends in Neurosciences · doi:10.1016/j.tins.2012.04.010 · Cited by 73 · see citing works
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35 · see citing works
Massalimova, A., Ni, R., Nitsch, R. M., Reisert, M., von Elverfeldt, D., & Klohs, J. (2020) · Neurodegenerative Diseases · doi:10.1159/000515754 · Cited by 28 · see citing works
- Authors
- Baltes, C., Radzwill, N., Bosshard, S., Marek, D., & Rudin, M.
- Affiliations
- University of Zurich (CH)
- Bruker (Switzerland) (CH)
- Corresponding author
- Baltes, Christof
- ORCID
- Rudin, Markus
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2009-06-17
- Volume
- 22
- Issue
- 8
- Pages
- 834-842
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2148369313
- Semantic Scholar
- 45bbbcc077777d4aad7bb3e2c4f5428eb01bd6a0
- Cited by
- 149
- References
- 35
- Citations by year
- 2026: 2 · 2025: 7 · 2024: 9 · 2023: 3 · 2022: 5 · 2021: 10 · 2020: 12 · 2019: 9 · 2018: 13 · 2017: 9 · 2016: 6 · 2015: 12 · 2014: 9 · 2013: 8 · 2012: 13
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- NMR in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Funders
- Swiss National Science Foundation SNF (3100A0-112835)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- small animal MRI, signal-to-noise ratio, cerebellum, cerebral cortex, magnetic resonance angiography, intracranial vasculature, Purkinje cells, 9.4 Tesla
- MeSH terms
- Animals, Brain, Cerebrovascular Circulation, Cold Temperature, Humans, Image Enhancement, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Radio Waves, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review