The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Abstract
The purpose of this work was to develop magnetic resonance elastography (MRE) for the fast and reproducible measurement of spatially averaged viscoelastic constants of living human brain. The technique was based on a phase‐sensitive echo planar imaging acquisition. Motion encoding was orthogonal to the image plane and synchronized to intracranial shear vibrations at driving frequencies of 25 and 50 Hz induced by a head‐rocker actuator. Ten time‐resolved phase‐difference wave images were recorded within 60 s and analyzed for shear stiffness and shear viscosity. Six healthy volunteers (six men; mean age 34.5 years; age range 25–44 years) underwent 23–39 follow‐up MRE studies over a period of 6 months. Interindividual mean ± SD shear moduli and shear viscosities were found to be 1.17 ± 0.03 kPa and 3.1 ± 0.4 Pas for 25 Hz and 1.56 ± 0.07 kPa and 3.4 ± 0.2 Pas for 50 Hz, respectively (P ≤ 0.01). The intraindividual range of shear modulus data was 1.01–1.31 kPa (25 Hz) and 1.33–1.77 kPa (50 Hz). The observed modulus dispersion indicates a limited applicability of Voigt's model to explain viscoelastic behavior of brain parenchyma within the applied frequency range. The narrow distribution of data within small confidence intervals demonstrates excellent reproducibility of the experimental protocol. The results are necessary as reference data for future comparisons between healthy and pathological human brain viscoelastic data. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC
Corpechot, C., El Naggar, A., Poujol-Robert, A., Ziol, M., Wendum, D., Chazouillères, O., de Lédinghen, V., Dhumeaux, D., Marcellin, P., Beaugrand, M., et al. (2006) · Hepatology · doi:10.1002/hep.21151 · Cited by 441
Cited by
Mechanisms of mechanical signaling in development and disease
Janmey, P. A., & Miller, R. T. (2011) · Journal of Cell Science · doi:10.1242/jcs.071001 · Cited by 461
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
The impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
Self-citationCharrier, E. E., Pogoda, K., Wells, R. G., & Janmey, P. A. (2018) · Nature Communications · doi:10.1038/s41467-018-02906-9 · Cited by 415
Mechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastography
Murphy, M. C., Huston, J., Jack, C. R., Glaser, K. J., Manduca, A., Felmlee, J. P., & Ehman, R. L. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22707 · Cited by 348
Fifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Klatt, D., Hamhaber, U., Asbach, P., Braun, J., & Sack, I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/24/006 · Cited by 333
Self-citationFeng, Y., Okamoto, R. J., Namani, R., Genin, G. M., & Bayly, P. V. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.04.007 · Cited by 316
Mechanics in Neuronal Development and Repair
Franze, K., Janmey, P. A., & Guck, J. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150045 · Cited by 314
MR-elastography reveals degradation of tissue integrity in multiple sclerosis
Wuerfel, J., Paul, F., Beierbach, B., Hamhaber, U., Klatt, D., Papazoglou, S., Zipp, F., Martus, P., Braun, J., & Sack, I. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.018 · Cited by 309
Self-citationAssessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
Self-citationMagnetic resonance elastography of frontotemporal dementia
Huston, J., Murphy, M. C., Boeve, B. F., Fattahi, N., Arani, A., Glaser, K. J., Manduca, A., Jones, D. T., & Ehman, R. L. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24977 · Cited by 68
Brain palpation from physiological vibrations using MRI
Zorgani, A., Souchon, R., Dinh, A.-H., Chapelon, J.-Y., Ménager, J.-M., Lounis, S., Rouvière, O., & Catheline, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509895112 · Cited by 69
Kolipaka, A., Schroeder, S., Mo, X., Shah, Z., Hart, P. A., & Conwell, D. L. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.04.015 · Cited by 60
Lagerstrand, K., Gaedes, N., Eriksson, S., Farahmand, D., De Coursey, E., Johansson, G., Jönsson, L., & Skoglund, T. (2021) · Pituitary · doi:10.1007/s11102-021-01129-4 · Cited by 43
Metadata
- Authors
- Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2007-07-05
- Volume
- 21
- Issue
- 3
- Pages
- 265-271
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1980151067
- Cited by
- 316
- References
- 41
- FWCI
- 12.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.