The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A novel background field removal method for MRI using projection onto dipole fields (PDF)
Open accessAbstract
For optimal image quality in susceptibility‐weighted imaging and accurate quantification of susceptibility, it is necessary to isolate the local field generated by local magnetic sources (such as iron) from the background field that arises from imperfect shimming and variations in magnetic susceptibility of surrounding tissues (including air). Previous background removal techniques have limited effectiveness depending on the accuracy of model assumptions or information input. In this article, we report an observation that the magnetic field for a dipole outside a given region of interest (ROI) is approximately orthogonal to the magnetic field of a dipole inside the ROI. Accordingly, we propose a nonparametric background field removal technique based on projection onto dipole fields (PDF). In this PDF technique, the background field inside an ROI is decomposed into a field originating from dipoles outside the ROI using the projection theorem in Hilbert space. This novel PDF background removal technique was validated on a numerical simulation and a phantom experiment and was applied in human brain imaging, demonstrating substantial improvement in background field removal compared with the commonly used high‐pass filtering method. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Mathematical Methods and Algorithms for Signal Processing
Moon, T. K., & Stirling, W. C. (1999) · Cited by 1,491
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Self-citationMarques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
de Rochefort, L., Brown, R., Prince, M. R., & Wang, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21710 · Cited by 293
Self-citationCusack, R., & Papadakis, N. (2002) · NeuroImage · doi:10.1006/nimg.2002.1092 · Cited by 287
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content
Yao, B., Li, T.-Q., Gelderen, P. V., Shmueli, K., de Zwart, J. A., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.029 · Cited by 282
Susceptibility mapping in the human brain using threshold‐based k‐space division
Wharton, S., Schäfer, A., & Bowtell, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22334 · Cited by 244
Kressler, B., de Rochefort, L., Liu, T., Spincemaille, P., Jiang, Q., & Wang, Y. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2023787 · Cited by 220
Self-citationArtery and vein separation using susceptibility-dependent phase in contrast-enhanced MRA
Wang, Y., Yu, Y., Li, D., Bae, K. T., Brown, J. J., Lin, W., & Haacke, E. M. (2000) · Journal of Magnetic Resonance Imaging · Cited by 152
Self-citationMR susceptometry for measuring global brain oxygen extraction
Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20892 · Cited by 147
Quantifying arbitrary magnetic susceptibility distributions with MR
Li, L. Z., & LEIGH, J. S. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20054 · Cited by 132
Koch, K. M., Papademetris, X., Rothman, D. L., & de Graaf, R. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/24/007 · Cited by 126
de Rochefort, L., Nguyen, T. D., Brown, R., Spincemaille, P., Choi, G. H., Weinsaft, J. W., Prince, M. R., & Wang, Y. (2008) · Medical Physics · doi:10.1118/1.3002309 · Cited by 78
Self-citationNeelavalli, J., Cheng, Y. N., Jiang, J., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21693 · Cited by 76
Langham, M. C., Magland, J. F., Floyd, T. F., & Wehrli, F. W. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21499 · Cited by 66
High-Precision Mapping of the Magnetic Field Utilizing the Harmonic Function Mean Value Property
Li, L. Z., & LEIGH, J. S. J. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2267 · Cited by 47
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citationLangkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Metadata
- Authors
- Liu, T., Khalidov, I., de Rochefort, L., Spincemaille, P., Liu, J., Tsiouris, A. J., & Wang, Y.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2011-03-08
- Volume
- 24
- Issue
- 9
- Pages
- 1129-1136
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2082914617
- Cited by
- 455
- References
- 25
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.