CoChat

Mechanisms of T2* anisotropy and gradient echo myelin water imaging

Lee, Jongho, Nam, Yoonho, Choi, Joon Yul, Kim, Eung Yeop, Oh, Se‐Hong, Kim, Dong‐Hyun · 2017 · NMR in Biomedicine
Cited by 48

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

In MRI, structurally aligned molecular or micro‐organization (e.g. axonal fibers) can be a source of substantial signal variations that depend on the structural orientation and the applied magnetic field. This signal anisotropy gives us a unique opportunity to explore information that exists at a resolution several orders of magnitude smaller than that of typical MRI. In this review, one of the signal anisotropies, T2* anisotropy in white matter, and a related imaging method, gradient echo myelin water imaging (GRE‐MWI), are explored. The T2* anisotropy has been attributed to isotropic and anisotropic magnetic susceptibility of myelin and compartmentalized microstructure of white matter fibers (i.e. axonal, myelin, and extracellular space). The susceptibility and microstructure create magnetic frequency shifts that change with the relative orientation of the fiber and the main magnetic field, generating the T2* anisotropy. The resulting multi‐component magnitude decay and nonlinear phase evolution have been utilized for GRE‐MWI, assisting in resolving the signal fraction of the multiple compartments in white matter. The GRE‐MWI method has been further improved by signal compensation techniques including physiological noise compensation schemes. The T2* anisotropy and GRE‐MWI provide microstructural information on a voxel (e.g. fiber orientation and tissue composition), and may serve as sensitive biomarkers for microstructural changes in the brain. Copyright © 2016 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.3513

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 48

Metadata

Authors
Lee, J., Nam, Y., Choi, J. Y., Kim, E. Y., Oh, S., & Kim, D.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2016-04-07
Volume
30
Issue
4
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W2341202188
Cited by
48
References
12
FWCI
5.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanisms of T2* anisotropy and gradient echo myelin water imaging. https://app.cochat.ai/papers/10.1002/nbm.3513
The paper
Lee, J., Nam, Y., Choi, J. Y., Kim, E. Y., Oh, S., & Kim, D. (2017). Mechanisms of T2* anisotropy and gradient echo myelin water imaging. NMR in Biomedicine. https://doi.org/10.1002/nbm.3513

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.