A framework based on spin glass models for the inference of anatomical connectivity from diffusion‐weighted MR data – a technical review
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A family of methods aiming at the reconstruction of a putative fascicle map from any diffusion‐weighted dataset is proposed. This fascicle map is defined as a trade‐off between local information on voxel microstructure provided by diffusion data and a priori information on the low curvature of plausible fascicles. The optimal fascicle map is the minimum energy configuration of a simulated spin glass in which each spin represents a fascicle piece. This spin glass is embedded into a simulated magnetic external field that tends to align the spins along the more probable fiber orientations according to diffusion models. A model of spin interactions related to the curvature of the underlying fascicles introduces a low bending potential constraint. Hence, the optimal configuration is a trade‐off between these two kind of forces acting on the spins. Experimental results are presented for the simplest spin glass model made up of compass needles located in the center of each voxel of a tensor based acquisition. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Self-citationDiffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Cited by
Fiber tracking: principles and strategies – a technical review
Mori, S., & van Zijl, P. C. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.781 · Cited by 2,024
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571
Diffusion MRI of complex neural architecture.
Tuch, D. S., Reese, T. G., Wiegell, M. R., & Wedeen, V. J. (2003) · Neuron · doi:10.1016/s0896-6273(03)00758-x · Cited by 698
Diffusion MRI at 25: exploring brain tissue structure and function
Le Bihan, D., & Johansen-Berg, H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.006 · Cited by 498
Self-citationQuantitative evaluation of 10 tractography algorithms on a realistic diffusion MR phantom
Fillard, P., Descoteaux, M., Goh, A., Gouttard, S., Jeurissen, B., Malcolm, J., Ramirez-Manzanares, A., Reisert, M., Sakaie, K., Tensaouti, F., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.032 · Cited by 418
Self-citation
Metadata
- Authors
- Mangin, J. ‐., Poupon, C., Cointepas, Y., Rivière, D., Papadopoulos‐Orfanos, D., Clark, C. A., Régis, J., & Le Bihan, D.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 15
- Issue
- 7-8
- Pages
- 481-492
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1993438516
- Cited by
- 73
- References
- 3
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.