Blood pressure assessment in severe obesity: Validation of a forearm approach
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: Obesity is frequently associated with systemic hypertension. Blood pressure measure is inaccurate in severely obese patients because of poor cuff size fitting. The aim of the study is to assess the degree of agreement between the intra‐arterial method as the gold standard vs. noninvasive methods, i.e., forearm blood pressure and upper‐arm blood pressure measures. Design and Methods: A total of 1285 measures of intra‐arterial and forearm blood pressure were taken in 51 severely obese patients in a supine position in the operating and the recovery room. A subset of 352 upper‐arm measures were taken in the recovery room and compared to the intra‐arterial and the forearm methods. Results: Correlation between the intra‐arterial and the forearm measures was 0.90 (P < 0.001) for the 2570 data (systolic and diastolic). Compared to intra‐arterial, the forearm method overestimated systolic (6 ± 16 mm Hg, P < 0.001) and underestimated diastolic blood pressure (2 ± 11 mm Hg, P = 0.03). Compared to intra‐arterial, upper‐arm underestimated systolic (8 ± 16 mm Hg, P < 0.01) and overestimated diastolic blood pressure (9 ± 7 mm Hg, P < 0.001). Conclusion: The magnitude of differences between the intra‐arterial and forearm method was less than differences between the intra‐arterial and upper‐arm method. Our results suggest that forearm method may be a more accurate alternative to upper‐arm measurement to assess blood pressure in severely obese patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Poirier, P., Cornier, M.-A., Mazzone, T., Stiles, S., Cummings, S., Klein, S., McCullough, P. A., Ren Fielding, C., & Franklin, B. A. (2011) · Circulation · doi:10.1161/cir.0b013e3182149099 · Cited by 339
Self-citationArterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115
Cited by
Flynn, J. T., Kaelber, D. C., Baker-Smith, C. M., Blowey, D., Carroll, A. E., Daniels, S. R., de Ferranti, S. D., Dionne, J. M., Falkner, B., Flinn, S. K., et al. (2017) · Pediatrics · doi:10.1542/peds.2017-1904 · Cited by 3,651
Staley, J. R., & Burgess, S. (2017) · Genetic Epidemiology · doi:10.1002/gepi.22041 · Cited by 290
Armstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Irving, G., Holden, J., Stevens, R., & McManus, R. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012429 · Cited by 51
Halm, M. A. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2014364 · Cited by 15
Blood Pressure Measurement Challenges in Severely Obese Patients
Siddiqui, M., & Calhoun, D. A. (2019) · American Journal of Hypertension · doi:10.1093/ajh/hpy162 · Cited by 10
Metadata
- Authors
- Leblanc, M., Croteau, S., Ferland, A., Bussières, J., Cloutier, L., Hould, F., Biertho, L., Moustarah, F., Marceau, S., & Poirier, P.
- Venue
- Obesity
- Publisher
- Wiley
- Published
- 2013-06-22
- Volume
- 21
- Issue
- 12
- Pages
- E533-41
- ISSN
- 1930-7381 (ISSN-L)
- 1930-739X
- OpenAlex
- W1505458153
- Cited by
- 30
- References
- 3
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.