The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Orbitrap Mass Analyzer – Overview and Applications in Proteomics
Abstract
The orbitrap mass analyzer is proving itself as a useful addition to a proteomics tool box. The key attributes of this analyzer are accurate mass and high resolution similar to those achievable with FT ICR instrumentation. The basic principles underlying these capabilities, and how they translate into benefits in real-life proteomics experiments are discussed. The focus is on reviewing examples of protein identification with bottom-up and top-down approaches, and detection of post-translational modifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Self-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Self-citationElectrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Self-citationPerformance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass Spectrometer
Makarov, A., Denisov, E., Kholomeev, A., Balschun, W., Lange, O., Strupat, K., & Horning, S. (2006) · Analytical Chemistry · doi:10.1021/ac0518811 · Cited by 777
Self-citationDynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431
Self-citationInterfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314
Self-citationOlsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313
Tang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Macek, B., Waanders, L. F., Olsen, J. V., & Mann, M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500042-mcp200 · Cited by 197
Cited by
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationSorting Signals, N-Terminal Modifications and Abundance of the Chloroplast Proteome
Zybailov, B., Rutschow, H., Friso, G., Rudella, A., Emanuelsson, O., Sun, Q., & van Wijk, K. J. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001994 · Cited by 637
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
LipidXplorer: A Software for Consensual Cross-Platform Lipidomics
Herzog, R., Schuhmann, K., Schwudke, D., Sampaio, J. L., Bornstein, S. R., Schroeder, M., & Shevchenko, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029851 · Cited by 416
Mass spectrometry–based proteomics in cell biology
Walther, T. C., & Mann, M. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201004052 · Cited by 412
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Self-citationFeist, P., & Hummon, A. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16023537 · Cited by 288
Geiger, T., Wisniewski, J. R., Cox, J., Zanivan, S., Kruger, M., Ishihama, Y., & Mann, M. (2011) · Nature Protocols · doi:10.1038/nprot.2010.192 · Cited by 281
Proteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion Fragmentation
Geiger, T., Cox, J., & Mann, M. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.001537 · Cited by 254
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Evaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
Ahlf, D. R., Compton, P. D., Tran, J. C., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3004216 · Cited by 89
Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers
Shaw, J. B., & Brodbelt, J. S. (2013) · Analytical Chemistry · doi:10.1021/ac401634b · Cited by 28
Metadata
- Authors
- Scigelova, M., & Makarov, A.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2006-09
- Volume
- 6
- Issue
- S2
- Pages
- 16-21
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2163827634
- Cited by
- 288
- References
- 13
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.