The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
The detection, correlation, and comparison of peptide precursor and product ions from data independent LC‐MS with data dependant LC‐MS/MS
Abstract
The detection, correlation, and comparison of peptide and product ions from a data independent LC‐MS acquisition strategy with data dependent LC‐MS/MS is described. The data independent mode of acquisition differs from an LC‐MS/MS data acquisition since no ion transmission window is applied with the first mass analyzer prior to collision induced disassociation. Alternating the energy applied to the collision cell, between low and elevated energy, on a scan‐to‐scan basis, provides accurate mass precursor and associated product ion spectra from every ion above the LOD of the mass spectrometer. The method therefore provides a near 100% duty cycle, with an inherent increase in signal intensity due to the fact that both precursor and product ion data are collected on all isotopes of every charge‐state across the entire chromatographic peak width. The correlation of product to precursor ions, after deconvolution, is achieved by using reconstructed retention time apices and chromatographic peak shapes. Presented are the results from the comparison of a simple four protein mixture, in the presence and absence of an enzymatically digested protein extract from Escherichia coli. The samples were run in triplicate by both data dependant analysis (DDA) LC‐MS/MS and data‐independent, alternate scanning LC‐MS. The detection and identification of precursor and product ions from the combined DDA search results of the four protein mixture were used for comparison to all other data. Each individual set of data‐independent LC‐MS data provides a more comprehensive set of detected ions than the combined peptide identifications from the DDA LC‐MS/MS experiments. In the presence of the complex E. coli background, over 90% of the monoisotopic masses from the combined LC‐MS/MS identifications were detected at the appropriate retention time. Moreover, the fragmentation pattern and number of associated elevated energy product ions in each replicate experiment was found to be very similar to the DDA identifications. In the case of the corresponding individual DDA LC‐MS/MS experiment, 43% of the possible detectable peptides of interest were identified. The presented data illustrates that the time‐aligned data from data‐independent alternate scanning LC‐MS experiments is highly comparable to the data obtained via DDA. The obtained information can therefore be effectively and correctly deconvolved to correlate product ions with parent precursor ions. The ability to generate precursor‐product ion tables from this information and subsequently identify the correct parent precursor peptide will be illustrated in a companion manuscript.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Ishihama, Y., Oda, Y., Tabata, T., Sato, T., Nagasu, T., Rappsilber, J., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500061-mcp200 · Cited by 2,055
Peng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Self-citationAnderson, N. L., Polanski, M., Pieper, R., Gatlin, T., Tirumalai, R. S., Conrads, T. P., Veenstra, T. D., Adkins, J. N., Pounds, J. G., Fagan, R., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300127-mcp200 · Cited by 1,006
Use of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Automated approach for quantitative analysis of complex peptide mixtures from tandem mass spectra
Venable, J. D., Dong, M.-Q., Wohlschlegel, J., Dillin, A., & Yates, J. R. (2004) · Nature Methods · doi:10.1038/nmeth705 · Cited by 794
Quantitative Proteomic Analysis by Accurate Mass Retention Time Pairs
Silva, J. C., Denny, R., Dorschel, C. A., Gorenstein, M., Kass, I. J., Li, G.-Z., McKenna, T., Nold, M. J., Richardson, K., Young, P., et al. (2005) · Analytical Chemistry · doi:10.1021/ac048455k · Cited by 639
Self-citationLi, G., Vissers, J. P. C., Silva, J. C., Golick, D., Gorenstein, M. V., & Geromanos, S. J. (2009) · PROTEOMICS · doi:10.1002/pmic.200800564 · Cited by 557
Self-citationKrämer‐Albers, E., Bretz, N., Tenzer, S., Winterstein, C., Möbius, W., Berger, H., Nave, K., Schild, H., & Trotter, J. (2007) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.200700522 · Cited by 548
Cited by
Andromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
OpenSWATH enables automated, targeted analysis of data-independent acquisition MS data
Röst, H. L., Rosenberger, G., Navarro, P., Gillet, L., Miladinović, S. M., Schubert, O. T., Wolski, W., Collins, B. C., Malmström, J., Malmström, L., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.2841 · Cited by 765
Less label, more free: Approaches in label‐free quantitative mass spectrometry
Neilson, K. A., Ali, N. A., Muralidharan, S., Mirzaei, M., Mariani, M., Assadourian, G., Lee, A., van Sluyter, S. C., & Haynes, P. A. (2011) · PROTEOMICS · doi:10.1002/pmic.201000553 · Cited by 704
Metabolite identification and quantitation in LC-MS/MS-based metabolomics
Xiao, J. F., Zhou, B., & Ressom, H. W. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.08.009 · Cited by 620
Protein Corona of Nanoparticles: Distinct Proteins Regulate the Cellular Uptake
Ritz, S., Schöttler, S., Kotman, N., Baier, G., Musyanovych, A., Kuharev, J., Landfester, K., Schild, H., Jahn, O., Tenzer, S., et al. (2015) · Biomacromolecules · doi:10.1021/acs.biomac.5b00108 · Cited by 619
Li, G., Vissers, J. P. C., Silva, J. C., Golick, D., Gorenstein, M. V., & Geromanos, S. J. (2009) · PROTEOMICS · doi:10.1002/pmic.200800564 · Cited by 557
Self-citationBruderer, R., Bernhardt, O. M., Gandhi, T., Xuan, Y., Sondermann, J., Schmidt, M., Gomez-Varela, D., & Reiter, L. (2017) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra117.000314 · Cited by 492
Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., Levin, Y., Schild, H., & Tenzer, S. (2014) · Nature Methods · doi:10.1038/nmeth.2767 · Cited by 481
Role of spectral counting in quantitative proteomics
Lundgren, D. H., Hwang, S.-I., Wu, L., & Han, D. K. (2010) · Expert Review of Proteomics · doi:10.1586/epr.09.69 · Cited by 428
Mass Spectrometry–Based Proteomics and Network Biology
Bensimon, A., Heck, A. J. R., & Aebersold, R. (2012) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-072909-100424 · Cited by 410
Quantitative Proteomic Analysis of Histone Modifications
Huang, H., Lin, S., Garcia, B. A., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500491u · Cited by 370
Erde, J., Loo, R. R. O., & Loo, J. A. (2014) · Journal of Proteome Research · doi:10.1021/pr4010019 · Cited by 331
Gillet, L. C., Leitner, A., & Aebersold, R. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041535 · Cited by 323
Paglia, G., Angel, P., Williams, J. P., Richardson, K., Olivos, H. J., Thompson, J. W., Menikarachchi, L., Lai, S., Walsh, C., Moseley, A., et al. (2015) · Analytical Chemistry · doi:10.1021/ac503715v · Cited by 295
Self-citationMultiplexed and data‐independent tandem mass spectrometry for global proteome profiling
Chapman, J. D., Goodlett, D. R., & Masselon, C. D. (2014) · Mass Spectrometry Reviews · doi:10.1002/mas.21400 · Cited by 259
A Comparison of Labeling and Label-Free Mass Spectrometry-Based Proteomics Approaches
Patel, V. J., Thalassinos, K., Slade, S. E., Connolly, J. B., Crombie, A., Murrell, J. C., & Scrivens, J. H. (2009) · Journal of Proteome Research · doi:10.1021/pr900080y · Cited by 258
León, I. R., Schwämmle, V., Jensen, O. N., & Sprenger, R. R. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.025585 · Cited by 257
Proteomics on an Orbitrap Benchtop Mass Spectrometer Using All-ion Fragmentation
Geiger, T., Cox, J., & Mann, M. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.001537 · Cited by 254
Martin, C. J., Datta, A., Littlefield, C., Kalra, A., Chapron, C., Wawersik, S., Dagbay, K. B., Brueckner, C. T., Nikiforov, A., Danehy, F. T., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay8456 · Cited by 224
Mass Spectrometric Analysis of Histone Proteoforms
Yuan, Z.-F., Arnaudo, A. M., & Garcia, B. A. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-015959 · Cited by 64
Goretzki, B., Wiedemann, C., McCray, B. A., Schäfer, S. L., Jansen, J., Tebbe, F., Mitrovic, S.-A., Nöth, J., Cabezudo, A. C., Donohue, J. K., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39808-4 · Cited by 51
Fert-Bober, J., Murray, C. I., Parker, S. J., & Van Eyk, J. E. (2018) · Circulation Research · doi:10.1161/circresaha.118.310966 · Cited by 45
Metadata
- Authors
- Geromanos, S. J., Vissers, J. P. C., Silva, J. C., Dorschel, C. A., Li, G., Gorenstein, M. V., Bateman, R. H., & Langridge, J. I.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 9
- Issue
- 6
- Pages
- 1683-1695
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W1981536086
- Cited by
- 497
- References
- 28
- FWCI
- 14.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.