Chemical cross‐linking and native mass spectrometry: A fruitful combination for structural biology
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS) is becoming increasingly popular in the field of structural biology for analyzing protein three‐dimensional‐structures and for mapping protein–protein interactions. In this review, the specific contributions of chemical crosslinking and native MS are outlined to reveal the structural features of proteins and protein assemblies. Both strategies are illustrated based on the examples of the tetrameric tumor suppressor protein p53 and multisubunit vinculin‐Arp2/3 hybrid complexes. We describe the distinct advantages and limitations of each technique and highlight synergistic effects when both techniques are combined. Integrating both methods is especially useful for characterizing large protein assemblies and for capturing transient interactions. We also point out the future directions we foresee for a combination of in vivo crosslinking and native MS for structural investigation of intact protein assemblies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901 · cited 1×
“ble information on the overall topology and shape of the assembly.(76) Below, we describe the steps taken to derive this structural information and demonstrate”
BackgroundNative mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
A mechanism of ubiquitin-independent proteasomal degradation of the tumor suppressors p53 and p73
Asher, G., Tsvetkov, P., Kahana, C., & Shaul, Y. (2005) · Genes & Development · doi:10.1101/gad.319905 · Cited by 367 · cited 1×
“Similarly, protein degradation by the 750 kDa 20S proteasome complex is inhibited by interactions with small homodimeric proteins as NAD(P)H:quinone-oxidoreductase-1 (NQO1, 31kDa) and DJ-1 (20 kDa).(114,115) Unraveling the molecular mechanism underlying the action of such regulators requires the structural characteriz…”
BackgroundCryo-electron microscopy--a primer for the non-microscopist
Milne, J. L. S., Borgnia, M. J., Bartesaghi, A., Tran, E. E. H., Earl, L. A., Schauder, D. M., Lengyel, J., Pierson, J., Patwardhan, A., & Subramaniam, S. (2013) · The FEBS Journal · doi:10.1111/febs.12078 · Cited by 277
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175 · cited 1×
“Furthermore, the ability to select a precursor ion for MS/MS analysis was lately incorporated within the Orbitrap instrument.(85) Overall, although the extended mass range Orbitrap analyzer is still in its early days, it holds great promise to advance the field of native MS owing to its enhanced resolution and impress…”
BackgroundSnijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168 · cited 1×
“It is estimated that the upper limit of the instrument for intact protein complexes is currently at m/z of 25,000–30,000, corresponding to a mass of roughly 5 MDa in positive ion mode nESI.(84) Furthermore, the ability to select a precursor ion for MS/MS analysis was lately incorporated within the Orbitrap instrument.”
Cited by
Cross-Linking Mass Spectrometry: An Emerging Technology for Interactomics and Structural Biology
Yu, C., & Huang, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04431 · Cited by 353
Functionalizing nanoparticles with cancer-targeting antibodies: A comparison of strategies
Marques, A. C., Costa, P. J., Velho, S., & Amaral, M. H. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.035 · Cited by 349
Piersimoni, L., Kastritis, P. L., Arlt, C., & Sinz, A. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00786 · Cited by 314
Self-citationUnique insights to intrinsically disordered proteins provided by ion mobility mass spectrometry
Stuchfield, D., & Barran, P. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2018.01.007 · Cited by 72
Yugandhar, K., Gupta, S., & Yu, H. (2019) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.05.007 · Cited by 51
Metadata
- Authors
- Sinz, A., Arlt, C., Chorev, D., & Sharon, M.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 2015-05-27
- Volume
- 24
- Issue
- 8
- Pages
- 1193-1209
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W2163756713
- Cited by
- 130
- References
- 12
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemical cross‐linking and native mass spectrometry: A fruitful combination for structural biology. https://app.cochat.ai/papers/10.1002/pro.2696
- The paper
- Sinz, A., Arlt, C., Chorev, D., & Sharon, M. (2015). Chemical cross‐linking and native mass spectrometry: A fruitful combination for structural biology. Protein Science. https://doi.org/10.1002/pro.2696
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.