Efficient sequence analysis of the six gene products (7‐74 kDA) from the escherichia coli thiamin biosynthetic operon by tandem high‐resolution mass spectrometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The 10 5 resolving power and MS/MS capabilities of Fourier‐transform mass spectrometry provide electrospray ionization mass spectra containing > 100 molecular and fragment ion mass values of high accuracy. Applying these spectra to the detection and localization of errors and modifications in the DNA‐derived sequences of proteins is illustrated with the thiCEFSGH thiamin biosynthesis operon from Escherichia coli. Direct fragmentation of the multiply‐charged intact protein ions produces large fragment ions covering the entire sequence; further dissociation of these fragment ions provides information on their sequences. For ThiE (23 kDa), the entire sequence was verified in a single spectrum with an accurate (0.3 Da) molecular weight (M r) value, with confirmation from MS/MS fragment masses. Those for ThiH (46 kDa) showed that the M r value (1 Da error) represented the protein without the start Met residue. For ThiF (27 kDa), MS/MS localized a sequence discrepancy to a 34 residue peptide. The first 107 residues of ThiC (74 kDa) were shown to be correct, with C‐terminal heterogeneity indicated. For ThiG (predicted M r = 34 kDa), ESI/FTMS showed two components of 7,310.74 (ThiS) and 26,896.5 Da (ThiG); MS/MS uncovered three reading frame errors and a stop codon for the first protein. MS/MS ions are consistent with 68 fragments predicted by the corrected ThiS/ThiG DNA sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Cited by
Mass spectrometry of oligosaccharides
Zaia, J. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10073 · Cited by 804
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
“(22), used reversed-phase traps for simple step elution before ESI.”
MethodSelf-citationAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Self-citationEvolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Self-citationMass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Martin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Perspectives for mass spectrometry and functional proteomics
Godovac-Zimmermann, J., & Brown, L. R. (2001) · Mass Spectrometry Reviews · doi:10.1002/1098-2787(2001)20:1<1::aid-mas1001>3.0.co;2-j · Cited by 264
Large-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Informatics and multiplexing of intact protein identification in bacteria and the archaea
Meng, F., Cargile, B. J., Miller, L. M., Forbes, A. J., Johnson, J. R., & Kelleher, N. L. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-952 · Cited by 208
Self-citationProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Self-citationMass Analysis at the Advent of the 21st Century
McLuckey, S. A., & Wells, J. M. (2001) · Chemical Reviews · doi:10.1021/cr990087a · Cited by 179
Performance of a Linear Ion Trap-Orbitrap Hybrid for Peptide Analysis
Yates, J. R., Cociorva, D., Liao, L., & Zabrouskov, V. (2006) · Analytical Chemistry · doi:10.1021/ac0514624 · Cited by 175
Lermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Metadata
- Authors
- Kelleher, N. L., Taylor, S. V., Grannis, D., Kinsland, C., Chiu, H., Begley, T. P., & Mclafferty, F. W.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 1998-08
- Volume
- 7
- Issue
- 8
- Pages
- 1796-1801
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W2155065510
- Cited by
- 100
- References
- 1
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.